1. Home
  2. /
  3. Types
  4. /
  5. Quartz Cuvette
  6. /
  7. Quartz UV Cuvette
  8. /
  9. Micro Quartz UV Cuvette...

Micro Quartz UV Cuvette Cell 2 Polished Sides with Lid for Spectroscopic Analysis -TOQUARTZ®

TOQUARTZ® High precision micro quartz UV cuvette designed for spectrophotometric analysis with outstanding optical properties. Features 2 polished sides for light transmission and a secure lid to prevent sample evaporation and contamination. Manufactured from 99.98%+ pure fused quartz for superior UV-visible range performance.
No MOQ
Custom Design
Factory Direct
Tech Support

Features of Micro Quartz UV Cuvette Cell 2 Polished Sides with Lid

TOQUARTZ® Micro Quartz UV Cuvette Cell combines precision manufacturing with high-purity materials to deliver exceptional performance for spectroscopic applications. Each cuvette is carefully crafted to meet the demanding requirements of scientific and industrial analysis.

Optical Clarity

Micro Quartz UV Cuvette features 99.98%+ fused quartz with UV-Vis (200-2500nm) transmission for undistorted optical clarity and zero absorption peaks in spectroscopy.

Chemical Resistance

It resists laboratory acids/bases/salts/organic solvents per ISO 695 while maintaining integrity without degradation, making it suitable for a wide range of analytical applications without material degradation.

Precision Optical Surfaces

Dual-side polished optics achieve high flatness/parallelism per ISO 10110-8, ensuring consistent light paths, minimal distortion, and reliable spectrophotometry with reduced inter-sample variability.

Secure Lid Design

Precision-engineered lid prevents sample evaporation or contamination while maintaining integrity during extended analysis via tight environmental sealing.

micro quartz UV cuvette with lid used for preventing sample evaporation and contamination
TOQUARTZ® Micro Quartz UV Cuvette 2 Polished Sides with Lid

Technical Specifications & Dimensions of
Micro Quartz UV Cuvette Cell 2 Polished Sides with Lid

TOQUARTZ® Micro Quartz UV Cuvette Cells are manufactured to precise specifications, ensuring consistent performance across applications. Each specification is carefully controlled and verified during our quality assurance process.

Technical Specifications of Micro Quartz UV Cuvette Cell 2 Polished Side

Chemical Properties

MaterialFused Quartz (SiO₂)High purity synthetic quartz
Purity99.995% SiO₂Ultra-high purity grade
Chemical ResistanceExcellentResistant to most acids, bases, and solvents
HydrophobicityHydrophilicGood wettability with aqueous solutions
Thermal Expansion Coefficient5.5×10⁻⁷/KVery low thermal expansion
Maximum Operating Temperature600°CSuitable for high-temperature samples

Optical Properties

Wavelength Range200-2500nmFull UV-Vis-NIR spectrum
UV Transmission at 200nm≥85%Superior deep UV performance
UV Transmission at 220nm≥88%Ideal for protein analysis
UV Transmission at 260nm≥90%Optimized for DNA/RNA quantification
Visible Light Transmission≥92%400-700nm range
Refractive Index (589.3nm)1.458Standard for fused quartz
Surface Flatnessλ/10Optical grade polishing

Size of of Micro Quartz UV Cuvette Cell 2 Polished Sides with Lid

Micro Quartz UV Cuvette Cell 2 Polished Sides with Lid
ModelDescriptionWavelengthPath LengthVolumeThermostabilityOutline Dimension
AT-BSM-009560μl Micro Quartz UV Cuvette Cell 2 Polished Sides with Lid200nm-2500nm4mm560μl600℃12.5×12.5x45mm
Note: We offer custom specifications to meet your specific requirements. Contact our engineering team for consultation.

TOQUARTZ® Solving Critical Challenges with Micro Quartz UV Cuvette Cells

Micro Quartz UV Cuvette Cells for Precise Spectrophotometric Analysis

Spectrophotometer manufacturers and analytical laboratories require micro cuvettes with consistent optical properties for accurate measurement of small sample volumes. Traditional cuvettes often introduce measurement variability due to inconsistent path lengths or poor UV transmission properties, compromising data accuracy in critical applications like DNA/RNA quantification.

Key Advantages

TOQUARTZ® solution

A U.S.-based spectrophotometer OEM reported ±0.03mm path length variation in previous suppliers’ cuvettes, causing up to 8% deviation in DNA concentration readings.

After switching to TOQUARTZ® Micro Quartz UV Cuvettes with certified ±0.01mm tolerance, calibration drift was reduced by 72%, and instrument recalibration frequency dropped from weekly to monthly.

Micro Quartz Glass UV Cuvette for Medical Diagnostic Applications

Medical diagnostic equipment manufacturers integrate micro cuvettes into automated testing systems for blood, urine, and other biological sample analysis. Many standard cuvettes experience dimensional inconsistency during manufacturing, leading to system calibration issues and potential misdiagnosis in clinical settings.

Key Advantages

TOQUARTZ® solution

A German IVD device manufacturer faced 12% cuvette rejection rate due to dimensional mismatch with robotic arms.

TOQUARTZ® supplied cuvettes with verified ±0.05mm outer tolerance, reducing rejection rate to under 1.5%. This saved €18,000 annually in rework costs and improved system uptime by 9.2%.

Micro Fused Quartz UV Cuvette for UV Absorbance in High-Throughput Compound Screening

High-throughput compound screening (HTS) relies on precise UV absorbance in the 200–300nm range. Standard cuvettes often suffer from evaporation and inconsistent path lengths, affecting detection accuracy.
TOQUARTZ® Micro Quartz UV Cuvette with 2 Polished Sides and Lid ensures stable optical performance and sealed sample integrity. It helps reduce false negatives and improves hit rates in automated screening workflows.

Key Advantages

TOQUARTZ® solution

A South Korean pharmaceutical HTS lab reported 7.8% false negative rate due to sample evaporation in open-top cuvettes during 2-hour batch runs.

After switching to TOQUARTZ® Micro Quartz UV Cuvette with 2 Polished Sides and Lid, evaporation loss dropped to 1.2%, and hit rate accuracy improved by 9.6%, reducing compound retesting by 31% over a 3-month screening cycle.

Customization Services for TOQUARTZ®
Micro Quartz UV Cuvette Cell 2 Polished Sides with Lid

TOQUARTZ® offers comprehensive customization services for our Micro Quartz UV Cuvette Cells to meet your specific application requirements. Our engineering team works directly with you to develop solutions tailored to your unique needs.

Custom Dimensions

Perfect for specialized instruments with non-standard holders or applications requiring specific sample volumes.

Optical Configurations

Ideal for specialized applications like fluorescence, circular dichroism, or specialized optical analysis techniques.

Specialized Features

Designed for specialized research applications, automated systems, or continuous flow analysis requirements.

TOQUARTZ® Customization Process

This is the dedicated custom project workflow for Micro Quartz UV Cuvette with 2 Polished Sides and Lid. Each step is designed to ensure your specifications are accurately translated into production-ready cuvettes.

Technical Consultation

TOQUARTZ® begin by understanding your application needs for Micro Quartz UV Cuvette with 2 Polished Sides and Lid. Our engineers will review your required path length, volume, lid type, and optical configuration.

Drawing & Specification Confirmation

Based on your input, we provide a detailed technical drawing of the customized Micro Quartz UV Cuvette with 2 Polished Sides and Lid. You will confirm dimensions, tolerances, and material compatibility before prototyping.

Prototype Manufacturing & Testing

We produce a small batch of prototypes under controlled conditions using high-purity fused quartz. Each Micro Quartz UV Cuvette with 2 Polished Sides and Lid is tested for path length accuracy, UV transmission, and lid seal integrity.

Batch Production & Delivery

Upon prototype approval, we proceed to full-scale production with strict quality control. Your customized Micro Quartz UV Cuvette with 2 Polished Sides and Lid will be delivered with batch traceability and inspection reports.

Usage Guide of Micro Quartz UV Cuvette Cell 2 Polished Sides with Lid

Proper handling and maintenance of your Micro Quartz UV Cuvette Cells will ensure optimal performance and extend their service life. Follow these guidelines to achieve consistent, accurate results in your spectroscopic applications.

Proper Handling

Cleaning Procedures

Sample Loading

Storage Recommendations

Important Usage Notes

Expert Engineering Support for Your Micro Quartz UV Cuvette Requirements

Our dedicated engineering team is ready to assist with technical specifications, custom designs,
and application-specific questions about Micro Quartz UV Cuvette Cells with 2 polished sides.

Why Partner with TOQUARTZ

Direct Factory Advantage

As a direct manufacturer, we can cut out the numerous intermediate links.

Engineering Expertise

Technical team guides clients from material selection to design optimization, translating specs into deliverables.

Flexible Manufacturing

Handling standard & custom orders via small-batch expertise and prototyping rigor to meet urgent deadlines.

Quality
Assurance

Pre-shipment 3-step validation:
1. dimensional accuracy,
2. material purity ,
3. performance thresholds

Global Supply Chain

Reliable global logistics to industrial hubs (DE/US/JP/KR priority) with trackable milestones.

FAQ

Q: Why use a Micro Quartz UV Cuvette with 2 polished sides and lid?

A: The 2 polished sides configuration is optimal for standard spectrophotometric analysis where light passes through the sample in a single axis. This design provides a defined path length (4mm in our standard model) for accurate absorption measurements while minimizing material costs. The lid serves three critical purposes: preventing sample evaporation during analysis (especially important for volatile solvents), reducing contamination risk, and eliminating meniscus formation that can interfere with readings. For applications requiring fluorescence or 90° detection, we offer 4-sided polished versions as a custom option.

A: TOQUARTZ® Micro Quartz UV Cuvette Cells offer an exceptionally wide wavelength range of 200-2500nm, covering the UV, visible, and near-infrared regions of the spectrum. This makes them versatile for numerous analytical techniques. The high-purity fused quartz material (max. up to 99.995% SiO₂) provides superior transmission in the deep UV range, with ≥85% transmission at 200nm, ≥88% at 220nm, and ≥90% at 260nm. This performance is critical for applications like DNA/RNA quantification, protein analysis, and other UV-dependent analytical methods that require detection in the 200-400nm range where glass cuvettes are unsuitable.

A: TOQUARTZ® standard Micro Quartz UV Cuvette Cell (AT-BSM-009) features a 4mm path length with a precision tolerance of ±0.01mm. The path length is the distance light travels through the sample and is critical for quantitative analysis using Beer-Lambert law calculations. The 4mm path length offers an optimal balance between sensitivity and sample volume requirements. For samples with higher concentration, the shorter path length (compared to standard 10mm cuvettes) allows direct measurement without dilution, while still requiring only 560μl of sample. Custom path lengths from 0.5mm to 10mm are available upon request for specific application requirements.

A: TOQUARTZ® Micro Quartz UV Cuvette Cells exhibit excellent chemical resistance and are compatible with most laboratory solvents and solutions. They can withstand acids (except hydrofluoric acid), bases, alcohols, ketones, aliphatic and aromatic hydrocarbons, and aqueous solutions. The fused quartz material is highly resistant to chemical attack, making it suitable for a wide range of analytical applications. However, avoid prolonged exposure to hydrofluoric acid (HF) and hot concentrated phosphoric acid, which can etch quartz surfaces. Note that the lid material (standard PTFE/PE) may have different chemical compatibility than the quartz body; custom lid materials are available for specific solvent requirements.

A: Proper orientation of a Micro Quartz UV Cuvette with 2 polished sides is essential for accurate measurements. The polished sides (optical windows) should align with the light path of your spectrophotometer. In most instruments, this means positioning the cuvette so that the clear, polished sides face the light source and detector, while the frosted or non-polished sides are perpendicular to the light path. Our cuvettes typically have small orientation marks or frosted sides to help identify the optical path direction. For Z-dimension spectrophotometers, ensure the appropriate height alignment using adapters if necessary. If using for fluorescence measurements, position the cuvette so that the excitation beam enters through a polished face and fluorescence detection occurs at 90° through a non-polished side (or use our 4-sided polished cuvettes for this application).

Contact our engineering team for technical consultation and pricing. We’ll help you select the optimal specifications for your application requirements.

Scroll to Top

Get a Fast Quote Now

Tell us what you need — Receive tailored pricing and lead time with 6hours.

* We typically respond within 6h | No Spam