Designed for laboratory equipment manufacturers, research institutions, and analytical testing facilities requiring reliable spectrophotometric measurements.
Features of Standard Quartz Glass Round Bottom UV Cuvette
TOQUARTZ® Standard Quartz Glass Cuvette UV Sample Cell Round Bottom with Lid offers exceptional optical and physical properties ideal for analytical laboratories and spectroscopy applications requiring precise measurements in the UV range.
Optical Properties
-
Wide Spectral Range:
Excellent transmission from 200nm to 2500nm, making it ideal for UV-VIS spectroscopy applications -
High Transmittance:
>80% transmittance across the UV spectrum, verified through paired testing for consistency -
Optical Window Precision:
Two precisely polished optical windows with parallelism ≤3 arc minutes for accurate readings -
No Absorption Peaks:
Ultra-pure quartz material (99.98%+ SiO₂) ensures no interfering absorption peaks in the analytical range
Physical Properties
-
Chemical Resistance:
Highly resistant to acids, bases, solvents, and salt solutions, suitable for diverse analytical applications -
Thermal Stability:
Low thermal expansion coefficient (5.5×10⁻⁷/K) provides stability during temperature fluctuations -
Secure Lid Design:
Prevents sample evaporation and contamination during storage and measurement -
Round Bottom Configuration:
Optimized for liquid samples, minimizing trapped air bubbles for more consistent readings

- Wide Spectral Range (200-2500nm)
- Thermal Stability (1100°C+)
- Custom Design Support
Technical Specifications & Dimensions of
Standard Quartz Glass Round Bottom UV Cuvette
Technical Specifications of Standard Quartz Glass Round Bottom UV Cuvette
Category | Parameter | Specification / Value | Notes / Tolerance |
General | Model Number | AT-BSM-010 / AT-BSM-019 | Standard models with identical dimensions |
Material | Quartz Grade | Synthetic Fused Silica (≥99.99% SiO₂) | High-purity UV-grade quartz |
Optical | Wavelength Transmission Range | 200 – 2500 nm | Verified by spectrophotometric testing |
UV Transmittance | ≥ 80% @ 200–350 nm | Paired testing, matched cuvettes | |
Absorption Peaks | None in 200–2500 nm range | No intrinsic absorption | |
Refractive Index (nD @ 589 nm) | 1.4585 | ASTM standard for fused silica | |
Surface Finish | Optical polish on windows | Ra < 10 nm | |
Light Path Accuracy | ±0.1 mm | Ensures consistent absorbance readings | |
Chemical | Acid Resistance | Excellent (except HF) | Stable in HCl, HNO₃, H₂SO₄, etc. |
Alkali Resistance | Good (except hot concentrated NaOH/KOH) | Avoid prolonged exposure | |
Organic Solvent Compatibility | Excellent | Compatible with alcohols, ketones, DMSO | |
Hydrofluoric Acid Resistance | Not resistant | HF etches quartz | |
Solvent Absorption | None | Non-porous surface | |
Physical | Density | 2.2 g/cm³ | ISO 7875-1 |
Thermal Expansion Coefficient | 5.5 × 10⁻⁷ /K (20–300°C) | Very low, ideal for thermal stability | |
Softening Point | ~1680°C | High thermal resistance | |
Working Temperature (Max) | 1100°C (continuous), 1200°C (short-term) | Not applicable for cuvette use | |
Thermal Shock Resistance | Excellent | Can withstand rapid temperature changes | |
Electrical Resistivity | 10¹⁶ Ω·cm (at 20°C) | High dielectric strength | |
Surface Hardness | Mohs 5.5–6 | Scratch-resistant | |
Quality Control | Transmittance Matching | Paired within ±1% | For dual-beam spectrophotometers |
Cleanroom Packaging | Optional | For sensitive applications | |
Certification | Internal QC report available | ISO 9001 production environment |
Size of of Standard Quartz Glass Round Bottom UV Cuvette with Lid

Model | Description | Wavelength | Path Length | Volume | Transmittance | Outline Dimension |
AT-BSM-010 | Standard Quartz Glass Cuvette UV Corrosion Resistant Cell with Lid without Glue | 200nm-2500nm | 10mm | 3.5ml | >80% (Paired Testing) | 12.5×12.5x45mm |

Model | Description | Wavelength | Path Length | Volume | Transmittance | Outline Dimension |
AT-BSM-019 | Standard Quartz Cuvette UV Sample Cell Round Bottom with Lid | 200nm-2500nm | 10mm | 3.5ml | >80% (Paired Testing) | 12.5×12.5x45mm |
TOQUARTZ® Solving Critical Challenges with
Standard Quartz Glass Round Bottom UV Cuvette
Standard Quartz Glass Round Bottom UV Cuvette for Precision Laboratory Instrumentation
Key Advantages
-
Dimensional deviation ≤ ±0.1mm ensures compatibility with automated cuvette holders
Verified across 500+ units with 100% pass rate in slot-fit testing. -
Optical window parallelism ≤ 3 arc minutes minimizes beam deviation in dual-beam spectrophotometers
Reduces baseline drift by up to 0.005 AU in precision calibration tests. -
Batch-to-batch transmittance variation ≤ 1.2% @ 220nm
Ensures consistent calibration curves across production lots for analytical instruments.
TOQUARTZ® solution
A German spectrophotometer manufacturer reported ±0.2mm dimensional drift in cuvettes from previous suppliers, causing 7% calibration failure rate.
TOQUARTZ® delivered 1,000 units with verified ±0.1mm tolerance and ≤1.2% UV transmittance variation, reducing recalibration incidents to below 1% and enabling CE certification pass on first submission.
Standard Quartz Round Bottom UV Cuvette for Biological Research Applications
Key Advantages
-
UV transmittance ≥ 82% @ 260nm ensures accurate nucleic acid quantification
Validated by paired testing with <0.01 AU baseline absorbance. -
No absorption peaks between 200–300nm eliminates spectral interference in DNA/RNA assays
Enables detection sensitivity down to 2 ng/μl DNA concentration. -
Round bottom geometry reduces bubble retention by 65% compared to flat-bottom cuvettes
Improves measurement repeatability in micro-volume protocols.
TOQUARTZ® solution
A U.S. genomics lab observed 0.03–0.05 AU baseline noise using generic cuvettes, affecting DNA quantification accuracy.
After switching to TOQUARTZ® cuvettes with certified ≥82% @260nm transmittance, baseline noise dropped to <0.01 AU, improving quantification CV from 12% to 3.5% across 96-well runs.
Standard Fused Quartz Cuvette Round Bottom UV Cell for Medical Diagnostic Equipment
Key Advantages
-
Outer dimension tolerance ≤ ±0.1mm ensures robotic arm compatibility in auto-analyzers
Eliminates jamming events in 24/7 diagnostic workflows. -
Optical clarity deviation ≤ 0.5% across 200–800nm range
Supports consistent absorbance readings in clinical assays. -
100% QC inspection with serial batch traceability
Enables traceable rejection rate <0.5% in high-throughput production lines.
TOQUARTZ® solution
A leading Japanese medical diagnostics manufacturer experienced mounting rejection rates of 12% with their previous supplier's cuvettes, resulting in costly production delays.
TOQUARTZ implemented enhanced quality control protocols specifically for their requirements, reducing dimensional variations to within ±0.1mm and cutting rejection rates to below 1%, saving approximately $45,000 annually in wasted materials and production time.
Customization Services for TOQUARTZ®
Standard Quartz Glass UV Cuvette Round Bottom
Dimensional Customization
- Custom path lengths
- Non-standard outer dimensions
- Volume modifications
- Height adjustments for specific instruments
Functional Modifications
- Alternative lid/cap designs
- Flow-through ports or tubulations
- Multiple optical windows (3-6 windows)
- Special surface treatments
Application-Specific Features
- Micro-volume designs
- Black-walled for fluorescence applications
- Graduated markings for volume reference
- Instrument-specific compatibility designs
TOQUARTZ® Customization Process
Technical Requirement Collection
TOQUARTZ® engineers begin by reviewing your specific application needs for the Standard Quartz Glass Cuvette UV Sample Cell round bottom with lid. This includes path length, lid type, volume, and compatibility with your spectrophotometer.
Custom Drawing & Design Proposal
We provide a detailed technical drawing of the customized cuvette within 3–5 business days. The design includes dimensional tolerances, optical window specifications, and lid sealing structure tailored to your requirements.
Prototype Sample Fabrication
For new designs or critical tolerances, we offer prototype production of the customized Standard Quartz Glass Cuvette UV Sample Cell round bottom with lid. This allows you to validate fit, optical performance, and instrument compatibility before mass production.
Optical & Dimensional Quality Verification
Each prototype or batch undergoes full QC testing, including UV transmittance at 260nm and dimensional accuracy within ±0.1mm. We provide paired testing reports to ensure consistency for dual-beam spectrophotometers.
Batch Production & Delivery
Once approved, we proceed to batch manufacturing with traceable lot numbers. Standard lead time for customized Standard Quartz Glass Cuvette UV Sample Cell round bottom with lid is 2–3 weeks, depending on complexity and quantity.
Usage Guide of Standard Quartz Glass Round Bottom UV Cuvette
Cleaning and Maintenance
-
Immediate Rinsing
Rinse with deionized water immediately after use to prevent sample residue from drying on surfaces. -
Cleaning Solutions
For stubborn residues, use dilute laboratory detergent solutions, followed by thorough rinsing with deionized water. For organic residues, ethanol or methanol can be effective. -
Avoid Abrasives
Never use abrasive cleaners or brushes that could scratch the optical surfaces. -
Drying
Air dry in a dust-free environment or use pure compressed air/nitrogen to blow-dry. Avoid paper towels which can leave fibers. -
Storage
Store clean, dry cuvettes in their original containers or dedicated storage racks to protect optical windows from scratches and contamination.
Handling and Measurement Procedures
-
Sample Preparation
Filter samples when possible to remove particulates that might scatter light and affect readings. -
Filling the Cuvette
Fill to approximately 2/3 capacity (about 2.5ml) to ensure the light path passes through the sample without interference from the meniscus. -
Bubble Removal
Gently tap the round bottom of the cuvette to dislodge any air bubbles that might interfere with readings. -
Cuvette Orientation
Place the cuvette in the spectrophotometer with the transparent optical windows facing the light path. The opaque sides should be perpendicular to the light path. -
Handling Optical Surfaces
Never touch the optical windows with bare fingers. Always handle the cuvette by the top or opaque sides.
Solvent Compatibility of Standard Quartz Glass UV Cuvettes
- Water and aqueous buffers
- Alcohols (methanol, ethanol)
- Acetone and acetonitrile
- DMSO
- Dilute acids and bases
- Hexane and other hydrocarbons
- Chloroform
- Most organic solvents
Need Expert Guidance on Standard Quartz Round Bottom UV Cuvettes?
Why Partner with TOQUARTZ
Direct Factory Advantage
As a direct manufacturer, we can cut out the numerous intermediate links.
Engineering Expertise
Technical team guides clients from material selection to design optimization, translating specs into deliverables.
Flexible Manufacturing
Handling standard & custom orders via small-batch expertise and prototyping rigor to meet urgent deadlines.
Quality
Assurance
Pre-shipment 3-step validation:
1. dimensional accuracy,
2. material purity ,
3. performance thresholds
Global Supply Chain
Reliable global logistics to industrial hubs (DE/US/JP/KR priority) with trackable milestones.
Releted Products
As a specialized manufacturer with direct factory capabilities, TOQUARTZ provides both standard and custom quartz solutions with engineering support throughout the specification and implementation process.
FAQ
Q: What is the wavelength range of Standard Quartz UV Cuvettes Round Bottom with Lid?
A: TOQUARTZ® Standard Quartz UV Cuvettes Round Bottom with Lid have an effective transmission range from 200nm to 2500nm, covering the entire UV and visible spectrum plus portions of the near-infrared range. This broad spectral coverage makes them versatile for multiple analytical applications. The transmittance is >80% across this range, with special attention to performance in the critical UV range (200-350nm) where many biomolecules have characteristic absorption peaks.
Q: What is the path length of Standard Quartz UV Cuvettes Round Bottom with Lid?
A: The standard path length for our model AT-BSM-010 Quartz UV Cuvette is 10mm (1cm), which is the most commonly used dimension in laboratory spectrophotometers. This path length is the distance light travels through the sample, and is critical for concentration calculations using Beer-Lambert law. We also offer custom path lengths ranging from 1mm (for highly concentrated samples) to 100mm (for very dilute solutions) upon request.
Q: How to clean Standard Quartz UV Cuvette Round Bottom with Lid?
A: For optimal performance, clean Standard Quartz UV Cuvettes immediately after use by rinsing with deionized water. For stubborn residues, use dilute laboratory detergent or appropriate solvents (ethanol, methanol, or acetone for organic residues), followed by thorough rinsing with deionized water. Never use abrasive cleaners or brushes that could scratch the optical surfaces. Air dry in a dust-free environment or use pure compressed air/nitrogen. Store clean, dry cuvettes in their original containers to protect optical windows from scratches and contamination.
Q: What solvents are compatible with Standard Quartz UV Cuvettes Round Bottom with Lid?
A: Standard Quartz UV Cuvettes are compatible with most laboratory solvents including water, aqueous buffers, alcohols (methanol, ethanol), acetone, acetonitrile, DMSO, dilute acids and bases, hexane and other hydrocarbons, chloroform, and most organic solvents. The high chemical resistance of quartz makes these cuvettes suitable for diverse analytical applications. However, hydrofluoric acid (HF) and concentrated hot alkaline solutions should be avoided as they can etch quartz surfaces.
Q: What is the Standard Quartz UV Cuvette Round Bottom with Lid direction for spectrophotometer placement?
A: When placing a Standard Quartz UV Cuvette Round Bottom with Lid in a spectrophotometer, the transparent optical windows should face the light path (typically the clear sides). The opaque sides (usually frosted or ribbed) should be perpendicular to the light path. Most cuvettes have a small arrow or mark indicating the correct orientation. Always handle the cuvette by the top or opaque sides to avoid fingerprints on the optical windows, which can interfere with measurements.
Q: What is the absorbance range of Standard Quartz UV Cuvettes Round Bottom with Lid?
A: Standard Quartz UV Cuvettes Round Bottom with Lid from TOQUARTZ® have minimal intrinsic absorbance in the UV-VIS range, typically less than 0.01 AU (absorbance units) across the 200-2500nm range. This low background absorbance allows for accurate measurement of sample absorbance without significant blank correction. The practical measurement range depends on your spectrophotometer sensitivity, but typically spans from 0.001 AU (for highly sensitive instruments) to 3.0 AU for most standard laboratory spectrophotometers.
Contact our engineering team for technical consultation and pricing. We’ll help you select the optimal specifications for your application requirements.