Standard Quartz UV Cuvette with Lid for UV Spectrophotometer -TOQUARTZ®
With path lengths from 0.5-10mm and wavelength range of 200-2500nm, these cuvettes deliver exceptional optical performance for research laboratories, medical diagnostics, and environmental monitoring equipment.
Features of Standard Quartz UV Cuvette
TOQUARTZ® Standard Quartz UV Cuvettes are engineered for precise spectroscopic analysis across laboratory, research, and industrial applications. Our cuvettes combine superior optical properties with excellent chemical resistance for reliable measurements in the UV-Vis spectrum range.
Material Properties
-
High Purity:
99.99% SiO₂ composition for superior optical clarity -
Chemical Resistance:
Stable against acids, bases, and most solvents -
Thermal Stability:
Operating temperature up to 1100°C -
Low Thermal Expansion:
~5.5×10⁻⁷ /°C coefficient
Optical Performance
-
Transmission Range:
200-2500nm wavelength coverage -
UV Transmittance:
>80% at 200nm (paired testing) -
Optical Surface Quality:
Ra<0.01μm for precise light transmission -
Polished Sides:
Two optical faces for perpendicular light path

- Wide Spectral Range (200-2500nm)
- Thermal Stability (1100°C+)
- Custom Design Support
Technical Specifications & Dimensions of
Standard Quartz Glass UV Cuvette with Lid
TOQUARTZ® Standard Quartz UV Cuvettes with lid are available in multiple configurations with various path lengths to accommodate different sample volumes and application requirements.
Technical Specifications of Standard Quartz UV Cuvette
Property | Value / Range | Unit / Description |
Material Composition | ≥99.99% SiO₂ | High-purity synthetic fused quartz |
Optical Transmission Range | 200 – 2500 | nm (UV to NIR) |
UV Transmittance @ 200nm | ≥80% (paired) | Measured with matched cuvette pair |
Refractive Index (at 589 nm) | 1.4585 | Dimensionless |
Density | 2.2 | g/cm³ |
Thermal Conductivity | 1.4 – 1.5 | W/m·K (at 20°C) |
Specific Heat Capacity | ~740 | J/kg·K (at 20°C) |
Softening Point | 1680 | °C |
Annealing Point | 1215 | °C |
Strain Point | 1120 | °C |
Maximum Operating Temperature | 1100 | °C (continuous use) |
Coefficient of Thermal Expansion | ~5.5 × 10⁻⁷ | /°C (20–1000°C range) |
Dielectric Strength | 250 – 400 | kV/cm |
Electrical Resistivity | >10¹⁸ | Ω·cm (at 20°C) |
Acid Resistance | Excellent | Resistant to HCl, HNO₃, H₂SO₄, etc. |
Alkali Resistance | Moderate | Limited resistance to strong hot alkalis |
HF Resistance | Poor | Not resistant to hydrofluoric acid |
Solvent Compatibility | Broad | Compatible with alcohols, ketones, hydrocarbons, etc. |
Surface Roughness (Polished) | Ra < 0.01 | μm (optical-grade polished surfaces) |
Light Scattering Loss | <0.5 | % (per optical surface, typical) |
Biocompatibility | Inert | Suitable for biological and chemical sample analysis |
Autoclavability | Yes | Can withstand standard autoclave sterilization cycles |
Size of of Standard Quartz UV Cuvette with Lid

Model | Description | Wavelength | Path Length | Volume | Transmittance | Outline Dimension |
AT-BSM-011 | 170μl Standard Quartz UV Cuvette with 2 Polished Sides and WITHOUT Lid for UV Spectrophotometer | 200nm-2500nm | 0.5mm | 170μl | >80% (Paired Testing) | 12.5x3x45 mm |

Model | Description | Wavelength | Path Length | Volume | Transmittance | Outline Dimension |
AT-BSM-058 | 350μl Standard Quartz UV Cuvette with 2 Polished Sides and Lid for UV Spectrophotometer | 200nm-2500nm | 1mm | 350μl | >80% (Paired Testing) | 12.5*3.5*45mm |

Model | Description | Wavelength | Path Length | Volume | Transmittance | Outline Dimension |
AT-BSM-017 | 700μl Standard Quartz UV Cuvette with 2 Polished Sides and Lid for UV Spectrophotometer | 200nm-2500nm | 2mm | 700μl | >80% (Paired Testing) | 12.5×4.5×45 mm |

Model | Description | Wavelength | Path Length | Volume | Transmittance | Outline Dimension |
AT-BSM-062 | 1.05ml Standard Quartz UV Cuvette with 2 Polished Sides and Lid for UV Spectrophotometer | 200nm-2500nm | 3mm | 1.05ml | >80% (Paired Testing) | 12.5*5.5*45mm |

Model | Description | Wavelength | Path Length | Volume | Transmittance | Outline Dimension |
AT-BSM-059 | 1.75ml Standard Quartz UV Cuvette with 2 Polished Sides and Lid for UV Spectrophotometer | 200nm-2500nm | 5mm | 1.75ml | >80% (Paired Testing) | 12.5×7.5×45 mm |

Model | Description | Wavelength | Path Length | Volume | Transmittance | Outline Dimension |
AT-BSM-015 | 3.5ml Standard Quartz UV Cuvette with 2 Polished Sides and Lid for UV Spectrophotometer | 200nm-2500nm | 10mm | 3.5ml | >80% (Paired Testing) | 12.5×12.5x45mm |

Model | Description | Wavelength | Path Length | Volume | Transmittance | Outline Dimension |
AT-BSM-061 | 4ml Standard Quartz UV Cuvette with 2 Polished Sides and Lid for UV Spectrophotometer | 200nm-2500nm | 10mm | 4ml | >80% (Paired Testing) | 13.5×14.5x43mm |
TOQUARTZ® Solving Critical Challenges with Standard Quartz UV Cuvettes
Standard Fused Quartz UV Cuvettes for Precision Laboratory Research
Key Advantages
-
Path Length Deviation ≤ ±0.1mm
Ensures <2% absorbance error in quantitative UV-Vis assays at 260nm. -
Optical Flatness Ra < 0.01μm
Minimizes baseline drift in nucleic acid and protein quantification. -
Batch Pairing ΔA < 0.005 @ 200nm
Paired cuvettes tested to ensure absorbance deviation <0.005 AU at 200nm.
TOQUARTZ® solution
U.S. research institutes reported experimental errors due to inconsistent path length tolerances exceeding ±0.2mm.
TOQUARTZ® Standard Quartz UV Cuvettes maintain ±0.1mm tolerance, reducing measurement variability by up to 15% and ensuring publication-quality data across multiple instrument platforms.
Standard Quartz Glass UV Cuvettes for Medical Diagnostic Equipment
Key Advantages
-
UV Transmission ≥ 82% @ 200nm
Enables accurate detection of low-concentration biomarkers in IVD systems. -
Bio-Inert Quartz Surface
Prevents protein adsorption during repeated diagnostic sample analysis. -
Dimensional Repeatability ±0.1mm
Ensures consistent optical alignment in automated diagnostic platforms.
TOQUARTZ® solution
A Korean IVD device manufacturer required cuvettes with ≥80% UV transmittance and zero protein binding for enzyme-based assays.
TOQUARTZ® delivered custom-tested cuvettes with 82.3% @ 200nm and verified inert surfaces, improving assay signal-to-noise ratio by 18% and reducing false negatives in clinical trials.
Standard Quartz UV Cuvettes for Environmental Monitoring Systems
Key Advantages
-
Acid Resistance pH 1–12
Maintains optical clarity after 100+ cycles in acidic water samples (pH 2). -
UV Stability under 24h Exposure
No transmittance degradation after 24h UV-C exposure at 254nm. -
Thermal Shock Tolerance >200°C
Withstands rapid temperature shifts in field-based water testing units.
TOQUARTZ® solution
Canadian environmental monitoring firms experienced rapid deterioration of standard cuvettes when testing acidic water samples, requiring replacement every 2-3 months.
TOQUARTZ® Standard Quartz UV Cuvettes withstand continuous exposure to pH 2-12 solutions, extending operational life to 12+ months and reducing annual replacement costs by approximately 70%.
Customization Services for TOQUARTZ® Standard Fused Quartz UV Cuvette
Available Customization Options
Custom Path Lengths
Non-standard
optical path lengths
Specialized Lid Types
· Screw caps
· PTFE plugs
· flow-through connections
Modified Dimensions
Custom height,
width, or wall
thickness
Special Optical Windows
Additional polished sides for
multi-directional measurements
Volume Adjustments
Optimized for
micro-volume or large
sample applications
TOQUARTZ® Customization Process
Requirement Consultation
TOQUARTZ®engineers will discuss your technical needs for a Standard Quartz UV Cuvette with lid, including path length, lid type, and optical window configuration. We help clarify application-specific constraints such as sample volume, solvent compatibility, and instrument fit.
Technical Drawing & Feasibility
You may provide your own drawings or collaborate with us to create a technical sketch for the customized Standard Quartz UV Cuvette with lid. We evaluate manufacturability based on quartz machining limits and optical alignment requirements.
Prototype Development
A sample Standard Quartz UV Cuvette with lid is produced based on approved drawings and specifications. This prototype is used for dimensional verification, optical testing, and lid sealing performance validation.
Performance Testing & Validation
We conduct UV transmittance testing (e.g., ≥80% @ 200nm) and chemical resistance checks on the customized cuvette. Paired absorbance deviation and lid integrity are verified to ensure batch consistency.
Batch Production & Delivery
Upon prototype approval, we proceed with batch production of the customized Standard Quartz UV Cuvette with lid. Final products are inspected, packaged securely, and shipped globally with full documentation.
Usage Guide of Standard Quartz UV Cuvette with Lid
Cleaning and Maintenance
-
Rinse immediately after use
- Prevent sample residue buildup with appropriate solvent. -
Clean with compatible solvents
- For organic samples, use acetone, ethanol, or methanol. For aqueous solutions, use deionized water followed by ethanol. -
Avoid abrasive materials
- Never use paper towels or abrasive cleaners on optical surfaces. -
Dry properly
- Air dry in clean environment or use compressed air (oil-free). -
Store in protective case
- Keep in original packaging or dedicated cuvette holders.
Handling and Operation
-
Clean before first use
- Remove any manufacturing residues with spectroscopic-grade solvent. -
Hold by non-optical surfaces
- Avoid touching polished sides to prevent fingerprints and contamination. -
Fill properly
- For standard 10mm cuvettes, 3ml sample volume is optimal (approximately 3/4 full). -
Orient correctly
- Align polished sides perpendicular to the light path in your spectrophotometer. -
Secure lid properly
- Tighten gently to prevent sample evaporation and contamination.
Solvent Compatibility of Standard Quartz UV Cuvettes
-
Compatible Solvents
• Water (all pH ranges)
• Alcohols (Methanol, Ethanol)
• Acetone
• Acetonitrile
• Hexane
• Toluene
• Chloroform
• Most dilute acids and bases
-
Use with Caution
• Concentrated HF (hydrofluoric acid)
• Hot concentrated phosphoric acid
• Hot concentrated alkali solutions
• Molten salts containing alkali metals
Need Standard Quartz UV Cuvettes for Your Application?
Why Partner with TOQUARTZ
Direct Factory Advantage
As a direct manufacturer, we can cut out the numerous intermediate links.
Engineering Expertise
Technical team guides clients from material selection to design optimization, translating specs into deliverables.
Flexible Manufacturing
Handling standard & custom orders via small-batch expertise and prototyping rigor to meet urgent deadlines.
Quality
Assurance
Pre-shipment 3-step validation:
1. dimensional accuracy,
2. material purity ,
3. performance thresholds
Global Supply Chain
Reliable global logistics to industrial hubs (DE/US/JP/KR priority) with trackable milestones.
Releted Products
As a specialized manufacturer with direct factory capabilities, TOQUARTZ provides both standard and custom quartz solutions with engineering support throughout the specification and implementation process.
FAQ
Q: Why use a Standard Quartz UV Cuvette with Lid instead of glass cuvettes?
A: Quartz cuvettes transmit light in the UV range (below 350nm) where glass cuvettes absorb radiation. This makes quartz essential for UV spectroscopy applications. The addition of a lid prevents sample evaporation, contamination, and provides safer handling of hazardous materials.
Q: What is the Standard Quartz UV Cuvette with Lid path length and why does it matter?
A: The path length is the distance light travels through the sample (typically 10mm in standard cuvettes). According to Beer-Lambert law, absorbance is directly proportional to path length, so different path lengths allow measurement of samples with varying concentrations. Shorter path lengths (0.5-5mm) are ideal for concentrated samples, while 10mm is standard for most applications.
Q: What is the wavelength range of Standard Quartz UV Cuvettes with Lid?
A: TOQUARTZ® Standard Quartz UV Cuvettes have a transmission range of 200-2500nm, covering ultraviolet, visible, and near-infrared regions. This makes them suitable for a wide range of spectroscopic applications from UV protein analysis (280nm) to visible colorimetric assays and near-IR applications.
Q: What is the correct Standard Quartz UV Cuvette with Lid direction in a spectrophotometer?
A: Insert the cuvette so that the light beam passes through the transparent (polished) sides. The polished sides should be perpendicular to the light path. Many cuvettes have arrow markings or orientation guides to indicate correct placement. The opaque sides should be parallel to the light path to prevent light scattering.
Q: What is the Standard Quartz UV Cuvette with Lid absorbance range?
A: For accurate measurements, the recommended absorbance range is 0.1-1.0 AU (absorbance units). Values below 0.1 may have high relative error due to instrument noise, while readings above 1.0 may show deviation from linearity. For concentrated samples exceeding this range, dilution or shorter path length cuvettes are recommended.
Q: How to clean Standard Quartz UV Cuvettes with Lid properly?
A: For routine cleaning, rinse with the solvent used in your analysis, followed by deionized water and a final rinse with spectroscopic-grade acetone or ethanol. For stubborn residues, soak in dilute HCl (0.1M) or specialized cuvette cleaning solution. Never use abrasive materials on optical surfaces. Air dry or use oil-free compressed air. Store in original packaging to prevent scratches.
Contact our engineering team for technical consultation and pricing. We’ll help you select the optimal specifications for your application requirements.