Standard Quartz Glass UV Cuvette with Round Bottom Design and Lid Configuration -TOQUARTZ®

The TOQUARTZ® Standard Quartz Glass Cuvette UV Sample Cell features a round bottom design with secure lid for precise UV-VIS spectroscopy applications.

Designed for laboratory equipment manufacturers, research institutions, and analytical testing facilities requiring reliable spectrophotometric measurements.
No MOQ
Custom Design
Factory Direct
Tech Support

Features of Standard Quartz Glass Round Bottom UV Cuvette

TOQUARTZ® Standard Quartz Glass Cuvette UV Sample Cell Round Bottom with Lid offers exceptional optical and physical properties ideal for analytical laboratories and spectroscopy applications requiring precise measurements in the UV range.

Optical Properties

Physical Properties

Round bottom design of Standard Quartz UV Cuvette with precision craftsmanship
TOQUARTZ® Standard Quartz UV Cuvette Round Bottom with Lid

Technical Specifications & Dimensions of
Standard Quartz Glass Round Bottom UV Cuvette

TOQUARTZ® Standard Quartz Round Bottom UV Cuvette with Lid specifications are carefully controlled to ensure compatibility with laboratory spectrophotometers and consistent analytical performance across different applications.

Technical Specifications of Standard Quartz Glass Round Bottom UV Cuvette

CategoryParameterSpecification / ValueNotes / Tolerance
GeneralModel NumberAT-BSM-010 / AT-BSM-019Standard models with identical dimensions
MaterialQuartz GradeSynthetic Fused Silica (≥99.99% SiO₂)High-purity UV-grade quartz
OpticalWavelength Transmission Range200 – 2500 nmVerified by spectrophotometric testing
UV Transmittance≥ 80% @ 200–350 nmPaired testing, matched cuvettes
Absorption PeaksNone in 200–2500 nm rangeNo intrinsic absorption
Refractive Index (nD @ 589 nm)1.4585ASTM standard for fused silica
Surface FinishOptical polish on windowsRa < 10 nm
Light Path Accuracy±0.1 mmEnsures consistent absorbance readings
ChemicalAcid ResistanceExcellent (except HF)Stable in HCl, HNO₃, H₂SO₄, etc.
Alkali ResistanceGood (except hot concentrated NaOH/KOH)Avoid prolonged exposure
Organic Solvent CompatibilityExcellentCompatible with alcohols, ketones, DMSO
Hydrofluoric Acid ResistanceNot resistantHF etches quartz
Solvent AbsorptionNoneNon-porous surface
PhysicalDensity2.2 g/cm³ISO 7875-1
Thermal Expansion Coefficient5.5 × 10⁻⁷ /K (20–300°C)Very low, ideal for thermal stability
Softening Point~1680°CHigh thermal resistance
Working Temperature (Max)1100°C (continuous), 1200°C (short-term)Not applicable for cuvette use
Thermal Shock ResistanceExcellentCan withstand rapid temperature changes
Electrical Resistivity10¹⁶ Ω·cm (at 20°C)High dielectric strength
Surface HardnessMohs 5.5–6Scratch-resistant
Quality ControlTransmittance MatchingPaired within ±1%For dual-beam spectrophotometers
Cleanroom PackagingOptionalFor sensitive applications
CertificationInternal QC report availableISO 9001 production environment

Size of of Standard Quartz Glass Round Bottom UV Cuvette with Lid

Standard Quartz Glass Cuvette UV Corrosion Resistant Cell with Lid without Glue
ModelDescriptionWavelengthPath LengthVolumeTransmittanceOutline Dimension
AT-BSM-010Standard Quartz Glass Cuvette UV Corrosion Resistant Cell with Lid without Glue200nm-2500nm10mm3.5ml>80% (Paired Testing)12.5×12.5x45mm
Standard Quartz Cuvette UV Sample Cell Round Bottom with Lid
ModelDescriptionWavelengthPath LengthVolumeTransmittanceOutline Dimension
AT-BSM-019Standard Quartz Cuvette UV Sample Cell Round Bottom with Lid200nm-2500nm10mm3.5ml>80% (Paired Testing)12.5×12.5x45mm
Note: We offer custom specifications to meet your specific requirements. Contact our engineering team for consultation.

TOQUARTZ® Solving Critical Challenges with
Standard Quartz Glass Round Bottom UV Cuvette

Standard Quartz Glass Round Bottom UV Cuvette for Precision Laboratory Instrumentation

Laboratory instrument manufacturers require precise optical components that maintain consistent performance across batches. Spectrophotometers rely on Standard Quartz UV Cuvettes with exact dimensions and optical properties to deliver accurate measurements. A German analytical instrument manufacturer reported inconsistent readings when using variable-quality cuvettes, affecting their equipment performance certification.

Key Advantages

TOQUARTZ® solution

A German spectrophotometer manufacturer reported ±0.2mm dimensional drift in cuvettes from previous suppliers, causing 7% calibration failure rate.

TOQUARTZ® delivered 1,000 units with verified ±0.1mm tolerance and ≤1.2% UV transmittance variation, reducing recalibration incidents to below 1% and enabling CE certification pass on first submission.

Standard Quartz Round Bottom UV Cuvette for Biological Research Applications

Research laboratories performing DNA/RNA quantification and protein analysis require exceptional UV transmission consistency in the 260-280nm range. Inferior cuvettes with absorption peaks or inconsistent transmittance can significantly distort nucleic acid concentration measurements. A U.S. research institution documented experimental errors in DNA quantification due to variable optical quality in their cuvettes.

Key Advantages

TOQUARTZ® solution

A U.S. genomics lab observed 0.03–0.05 AU baseline noise using generic cuvettes, affecting DNA quantification accuracy.
After switching to TOQUARTZ® cuvettes with certified ≥82% @260nm transmittance, baseline noise dropped to <0.01 AU, improving quantification CV from 12% to 3.5% across 96-well runs.

Standard Fused Quartz Cuvette Round Bottom UV Cell for Medical Diagnostic Equipment

Medical diagnostic equipment manufacturers require cuvettes with exceptional dimensional consistency for automated systems and high optical clarity for accurate patient sample analysis. Dimensional variations can cause mechanical failures in sample handling systems, while optical inconsistencies can lead to misdiagnosis. A Japanese diagnostic equipment manufacturer reported a 12% rejection rate due to cuvette dimensional inconsistencies.

Key Advantages

TOQUARTZ® solution

A leading Japanese medical diagnostics manufacturer experienced mounting rejection rates of 12% with their previous supplier's cuvettes, resulting in costly production delays.

TOQUARTZ implemented enhanced quality control protocols specifically for their requirements, reducing dimensional variations to within ±0.1mm and cutting rejection rates to below 1%, saving approximately $45,000 annually in wasted materials and production time.

Customization Services for TOQUARTZ®
Standard Quartz Glass UV Cuvette Round Bottom

TOQUARTZ® offers specialized customization services for Standard Quartz UV Cuvettes to meet unique application requirements beyond standard configurations.

Dimensional Customization

Functional Modifications

Application-Specific Features

TOQUARTZ® Customization Process

Technical Requirement Collection

TOQUARTZ® engineers begin by reviewing your specific application needs for the Standard Quartz Glass Cuvette UV Sample Cell round bottom with lid. This includes path length, lid type, volume, and compatibility with your spectrophotometer.

Custom Drawing & Design Proposal

We provide a detailed technical drawing of the customized cuvette within 3–5 business days. The design includes dimensional tolerances, optical window specifications, and lid sealing structure tailored to your requirements.

Prototype Sample Fabrication

For new designs or critical tolerances, we offer prototype production of the customized Standard Quartz Glass Cuvette UV Sample Cell round bottom with lid. This allows you to validate fit, optical performance, and instrument compatibility before mass production.

Optical & Dimensional Quality Verification

Each prototype or batch undergoes full QC testing, including UV transmittance at 260nm and dimensional accuracy within ±0.1mm. We provide paired testing reports to ensure consistency for dual-beam spectrophotometers.

Batch Production & Delivery

Once approved, we proceed to batch manufacturing with traceable lot numbers. Standard lead time for customized Standard Quartz Glass Cuvette UV Sample Cell round bottom with lid is 2–3 weeks, depending on complexity and quantity.

Usage Guide of Standard Quartz Glass Round Bottom UV Cuvette

Proper handling, cleaning, and storage of Standard Quartz Glass Cuvettes is essential for maintaining optical performance and extending their service life in laboratory applications.

Cleaning and Maintenance

Handling and Measurement Procedures

Solvent Compatibility of Standard Quartz Glass UV Cuvettes

Standard Quartz UV Cuvettes are compatible with most laboratory solvents and solutions, including:

Need Expert Guidance on Standard Quartz Round Bottom UV Cuvettes?

Our engineering team is available to provide free technical consultation for your specific application requirements.

Why Partner with TOQUARTZ

Direct Factory Advantage

As a direct manufacturer, we can cut out the numerous intermediate links.

Engineering Expertise

Technical team guides clients from material selection to design optimization, translating specs into deliverables.

Flexible Manufacturing

Handling standard & custom orders via small-batch expertise and prototyping rigor to meet urgent deadlines.

Quality
Assurance

Pre-shipment 3-step validation:
1. dimensional accuracy,
2. material purity ,
3. performance thresholds

Global Supply Chain

Reliable global logistics to industrial hubs (DE/US/JP/KR priority) with trackable milestones.

FAQ

Q: What is the wavelength range of Standard Quartz UV Cuvettes Round Bottom with Lid?

A: TOQUARTZ® Standard Quartz UV Cuvettes Round Bottom with Lid have an effective transmission range from 200nm to 2500nm, covering the entire UV and visible spectrum plus portions of the near-infrared range. This broad spectral coverage makes them versatile for multiple analytical applications. The transmittance is >80% across this range, with special attention to performance in the critical UV range (200-350nm) where many biomolecules have characteristic absorption peaks.

A: The standard path length for our model AT-BSM-010 Quartz UV Cuvette is 10mm (1cm), which is the most commonly used dimension in laboratory spectrophotometers. This path length is the distance light travels through the sample, and is critical for concentration calculations using Beer-Lambert law. We also offer custom path lengths ranging from 1mm (for highly concentrated samples) to 100mm (for very dilute solutions) upon request.

A: For optimal performance, clean Standard Quartz UV Cuvettes immediately after use by rinsing with deionized water. For stubborn residues, use dilute laboratory detergent or appropriate solvents (ethanol, methanol, or acetone for organic residues), followed by thorough rinsing with deionized water. Never use abrasive cleaners or brushes that could scratch the optical surfaces. Air dry in a dust-free environment or use pure compressed air/nitrogen. Store clean, dry cuvettes in their original containers to protect optical windows from scratches and contamination.

A: Standard Quartz UV Cuvettes are compatible with most laboratory solvents including water, aqueous buffers, alcohols (methanol, ethanol), acetone, acetonitrile, DMSO, dilute acids and bases, hexane and other hydrocarbons, chloroform, and most organic solvents. The high chemical resistance of quartz makes these cuvettes suitable for diverse analytical applications. However, hydrofluoric acid (HF) and concentrated hot alkaline solutions should be avoided as they can etch quartz surfaces.

A: When placing a Standard Quartz UV Cuvette Round Bottom with Lid in a spectrophotometer, the transparent optical windows should face the light path (typically the clear sides). The opaque sides (usually frosted or ribbed) should be perpendicular to the light path. Most cuvettes have a small arrow or mark indicating the correct orientation. Always handle the cuvette by the top or opaque sides to avoid fingerprints on the optical windows, which can interfere with measurements.

A: Standard Quartz UV Cuvettes Round Bottom with Lid from TOQUARTZ® have minimal intrinsic absorbance in the UV-VIS range, typically less than 0.01 AU (absorbance units) across the 200-2500nm range. This low background absorbance allows for accurate measurement of sample absorbance without significant blank correction. The practical measurement range depends on your spectrophotometer sensitivity, but typically spans from 0.001 AU (for highly sensitive instruments) to 3.0 AU for most standard laboratory spectrophotometers.

Contact our engineering team for technical consultation and pricing. We’ll help you select the optimal specifications for your application requirements.