UV-Transparent Wide-Spectrum Quartz UV Cuvette for Automated Biochemical Analyzer -TOQUARTZ®
Features of Quartz UV Cuvette for Automated Biochemical Analyzer
TOQUARTZ® quartz cuvettes for automated biochemical analyzers are manufactured from high-purity fused quartz material, offering exceptional optical and chemical properties required for precise spectrophotometric analysis in clinical and research settings.
Optical Properties
- Wide spectral range (200-2500nm)
- No absorption peaks in UV-VIS range
- High transmission rate (≥85% at 190-250nm)
- Paired testing for optical path consistency (>80%)
Material Properties
- High purity (≥99.98% SiO₂, max. up to 99.995%)
- Excellent chemical resistance to acids, bases, and solvents
- Low thermal expansion coefficient (5.5×10⁻⁷ /°C)
- High temperature resistance (up to 1100°C)
- SiO₂ content max. up to 99.995%
- Customizable design for specific requirements
- Tight dimensional tolerances (±0.1mm)
Technical Specifications & Dimensions of Quartz UV Cuvette for Automated Biochemical Analyzer
Technical Specifications
| Property | Specification | Test Method |
| 1. Chemical Properties | ||
| Material Composition | ≥99.995% SiO₂ | ICP-MS |
| Chemical Resistance | Resistant to most acids, bases, and solvents | Chemical Immersion Test |
| Water Absorption | Negligible | ASTM D570 |
| 2. Optical Properties | ||
| Wavelength Range | 200-2500nm | Spectrophotometer |
| UV Transmittance (190-250nm) | ≥85% | UV-VIS Spectroscopy |
| Optical Path Consistency | >80% (Paired Testing) | Comparative Analysis |
| Refractive Index (589.3nm) | 1.458 | Refractometer |
Size Chart
| Model | Description | Wavelength | Volume | Path Length | Thermostability | OD.xHeight |
| AT-BSM-074 | Quartz Cuvette for Automated Biochemical Analyzer | 200nm-2500nm | 0.54ml | 6mm | >80% (Paired Testing) | 7x8x27mm |
TOQUARTZ® Solving Critical Challenges in Biochemical Analysis with
Quartz UV Cuvette
Quartz Cuvette for Automated Biochemical Analyzer in Clinical Chemistry Laboratories
Key Advantages
-
Optical Path Deviation ≤ ±0.05mm
Ensures consistent absorbance readings across 10,000+ daily clinical samples. -
Batch-to-Batch Optical Consistency ≥ 92%
Reduces inter-batch calibration needs in high-throughput diagnostic workflows. -
Defect Rate < 0.3% in 50,000 Units
Minimizes false positives/negatives caused by cuvette imperfections.
TOQUARTZ® solution
A Polish hospital lab processing 6,000 samples/day faced 9% retest rates due to cuvette inconsistencies. After switching to TOQUARTZ cuvettes with ≤±0.05mm path deviation and ≥92% batch optical match, retests dropped to 1.1%. This improved diagnostic reliability and saved over €14,000/month in reagent and labor costs.
Quartz Cuvette for Automated Biochemical Analyzer in In-Vitro Diagnostic (IVD) Device Manufacturing
Key Advantages
-
Dimensional Tolerance Controlled Within ±0.1mm
Ensures seamless integration into OEM analyzer cuvette holders. -
24-Hour Dispatch for 12 Standard SKUs
Supports just-in-time assembly lines for IVD device manufacturers. -
Custom Production Lead Time ≤ 14 Days
Reduces analyzer launch delays by up to 40% compared to industry average.
TOQUARTZ® solution
A South Korean IVD manufacturer faced a 5-week delay from a previous supplier, risking a $1.2M analyzer delivery contract. TOQUARTZ delivered 3,500 custom cuvettes in 13 days with ±0.1mm tolerance, enabling on-time shipment. The client reported 0% integration issues and added TOQUARTZ to its preferred vendor list.
Quartz Cuvette for Automated Biochemical Analyzer in Pharmaceutical Quality Control Labs
Key Advantages
-
UV Transmission ≥ 88% @ 200nm (Certified)
Enables accurate quantification of trace-level analytes in drug formulations. -
Surface Roughness ≤ Ra 0.01μm (Polished Faces)
Minimizes light scattering and improves signal-to-noise ratio in UV-VIS assays. -
Bubble-Free Rate ≥ 99.8% (Dual QC Verified)
Reduces baseline drift in low-concentration impurity detection.
TOQUARTZ® solution
A Japanese pharmaceutical QC lab struggled with inconsistent UV readings during trace impurity testing. After adopting TOQUARTZ cuvettes with ≥88% UV transmission and Ra ≤0.01μm, signal-to-noise ratio improved by 34%, and detection limits dropped from 0.06 mg/L to 0.035 mg/L, meeting stringent ICH Q2(R1) validation standards.
Customization Services for TOQUARTZ® Quartz UV Cuvette for Automated Biochemical Analyzer
Dimensional Customization
- Custom internal volumes
- Modified optical path lengths
- Special form factors for proprietary analyzers
Surface Modifications
- Anti-reflective coatings for improved signal
- Hydrophobic treatments for easier cleaning
- Black mask coatings to reduce stray light
Engineering Support
- Reverse engineering of OEM parts
- CAD assistance and technical drawing
- Prototype development and testing
Usage Guide of Quartz UV Cuvette for Automated Biochemical Analyzer
Handling & Storage
- Always handle cuvettes with powder-free gloves to prevent fingerprints and contamination.
- Store in original packaging or dust-free containers when not in use.
- Avoid contact with hard surfaces that may scratch optical faces.
- Store in a dry environment (humidity <60%) to prevent contamination.
Installation
- Inspect for any defects or damage before installation.
- Verify correct orientation according to analyzer specifications.
- Ensure optical faces are perpendicular to the light path.
- Follow analyzer manufacturer's installation protocol for optimal results.
Cleaning & Maintenance
- Clean with mild laboratory detergent (pH 7-8) followed by thorough rinsing with deionized water.
- For stubborn residues, soak in 5% HCl or 5% HNO₃ for 30 minutes, then rinse thoroughly.
- Dry with clean, oil-free compressed air or nitrogen.
- Avoid abrasive materials or tissues that may scratch optical surfaces.
Performance Verification
- Perform regular baseline checks with standard solutions.
- Check for optical clarity by visual inspection against bright light.
- Replace if optical transmission decreases by >5% from original specifications.
- Implement a regular replacement schedule based on test volume (typically 10,000-50,000 tests).
Need Technical Assistance with UV Quartz Cuvette Specifications?
Why Partner with TOQUARTZ
Direct Factory Advantage
As a direct manufacturer, we can cut out the numerous intermediate links.
Engineering Expertise
Technical team guides clients from material selection to design optimization, translating specs into deliverables.
Flexible Manufacturing
Handling standard & custom orders via small-batch expertise and prototyping rigor to meet urgent deadlines.
Quality
Assurance
Pre-shipment 3-step validation:
1. dimensional accuracy,
2. material purity ,
3. performance thresholds
Global Supply Chain
Reliable global logistics to industrial hubs (DE/US/JP/KR priority) with trackable milestones.
Releted Products
As a specialized manufacturer with direct factory capabilities, TOQUARTZ provides both standard and custom quartz solutions with engineering support throughout the specification and implementation process.
FAQ
Q: What is a quartz cuvette used for in biochemical analysis?
A: Quartz cuvettes are used in biochemical analyzers to hold liquid samples for spectrophotometric analysis. They allow UV and visible light to pass through the sample with minimal absorption or interference, enabling accurate measurement of analyte concentrations in blood, serum, urine, and other biological fluids. Unlike glass cuvettes, quartz cuvettes can transmit UV light down to 190nm, which is essential for measuring proteins, nucleic acids, and many clinical biochemical markers.
Q: Can quartz cuvettes be used in automated analyzers?
A: Yes, TOQUARTZ® quartz cuvettes are specifically designed for automated biochemical analyzers. They feature precise dimensions (±0.1mm tolerance) that ensure proper fit and alignment in automated sample handling systems. The optical clarity and consistent wall thickness provide reliable measurement results in high-throughput settings. Our cuvettes are compatible with major analyzer brands and can be customized to meet specific instrument requirements.
Q: How do I clean a quartz cuvette used in a biochemical analyzer?
A: For routine cleaning, rinse the cuvette with deionized water immediately after use, followed by a mild laboratory detergent wash (pH 7-8), and thorough rinsing with deionized water again. For stubborn residues or protein buildup, soak in 5% HCl or 5% HNO₃ for 30 minutes, then rinse thoroughly. Dry with clean, oil-free compressed air or nitrogen. Avoid abrasive materials or tissues that may scratch optical surfaces. For automated systems, follow the analyzer manufacturer’s recommended cleaning protocol.
Q: What wavelength range does a quartz cuvette for automated biochemical analyzers support?
A: TOQUARTZ® high-purity quartz cuvettes support a wide spectral range from 200nm to 2500nm. They provide excellent transmission in both the ultraviolet (200-380nm) and visible (380-750nm) regions, with transmittance ≥85% at 190-250nm. Unlike glass cuvettes that absorb UV light below 320nm, quartz cuvettes allow for accurate UV analysis crucial for many biochemical applications. This broad wavelength compatibility makes them ideal for comprehensive spectrophotometric analysis in clinical chemistry.
Q: What should I look for when selecting a quartz cuvette for my analyzer?
A: Key factors include:
1) Dimensional accuracy – ensure precise fit for your specific analyzer model;
2) Material purity – higher purity (≥99.995% SiO₂) provides better UV transmission and fewer interference issues;
3) Surface quality – look for polished, bubble-free surfaces for optimal optical clarity;
4) Manufacturing precision – consistent wall thickness (±0.1mm) ensures reliable results;
5) Compatibility verification – confirm the cuvette is compatible with your analyzer’s sample handling system and optical path requirements.
Contact our engineering team for technical consultation and pricing. We’ll help you select the optimal specifications for your application requirements.