1. Home
  2. /
  3. Types
  4. /
  5. Quartz Cuvette
  6. /
  7. Quartz Fluorescence Cuvette
  8. /
  9. Spectral-Stable Quartz Fluorescence Reaction...

Spectral-Stable Quartz Fluorescence Reaction Cuvettes for Lab Applications -TOQUARTZ®

TOQUARTZ® high-purity (≥99.98%, max. up to 99.995% SiO₂) quartz fluorescence cuvette with a screw cap designed for demanding spectroscopic applications. Features excellent light transmission from 190nm to 2500nm with a standard 10mm path length. The precision-engineered screw cap ensures a tight seal for volatile or sensitive samples. Designed for fluorescence spectroscopy, photometric analysis, and chemical reaction monitoring. Available in standard and custom dimensions with PTFE or quartz cap options.
No MOQ
Custom Design
Factory Direct
Tech Support

Features of Quartz Fluorescence Reaction Cuvettes

TOQUARTZ® quartz fluorescence reaction cuvettes combine precision manufacturing with high-purity materials to deliver superior optical performance. Each cuvette is crafted to meet the exacting requirements of spectroscopic analysis and chemical reaction monitoring.

Material Purity

Manufactured from high-purity optical quartz with SiO₂ content up to 99.995%, ensuring minimal interference in sensitive analytical applications and excellent optical clarity.

Versatile Closure Options

Available with PTFE caps for chemical resistance or quartz lids for high-temperature applications, providing flexible sealing solutions for various experimental conditions.

Optical Transmission

Wide spectral transmission range from 190nm to 2500nm covers UV, visible, and near-infrared regions without absorption peaks, ideal for comprehensive spectroscopic analysis.

Chemical Resistance

Highly resistant to acids, bases, salts, and organic solvents, making these cuvettes suitable for aggressive chemical environments and extending their service life in laboratory settings.

Volatile-Sample Quartz Fluorescence Reaction Cuvettes for Controlled Analysis
TOQUARTZ® Quartz Fluorescence Reaction Cuvettes

Technical Specifications & Dimensions of Quartz Fluorescence
Reaction Cuvettes

TOQUARTZ® quartz fluorescence reaction cuvettes are manufactured to precise specifications, ensuring consistent performance across a wide range of analytical applications.

Technical Specifications

ParameterSpecification
1. Physical Properties
MaterialHigh-purity optical quartz (≥99.98%, max. up to 99.995% SiO2)
Surface FinishOptical grade polishing
Cap OptionsPTFE caps, quartz lids
Density2.2 g/cm³
Thermal Expansion Coefficient5.5×10⁻⁷ /°C
2. Chemical Properties
Acid ResistanceExcellent (except HF)
Alkali ResistanceVery good
Solvent CompatibilityCompatible with all common organic solvents
3. Optical Properties
Transmission Range200-2500nm
Refractive Index1.46 at 589.3nm
Transmission Rate≥80% (200-800nm)

Size Chart

20mm Quartz Fluorescence Reaction Cuvette Cell
ModelDescriptionPath
Length
VolumeOutline Dimension
AT-BSM-6006-420mm Quartz Fluorescence Reaction Cuvette Cell20mm800μl24x24x22mm
20mm Quartz Fluorescence Reaction Cuvette
ModelDescriptionPath
Length
VolumeOutline Dimension
AT-BSM-600620mm Quartz Fluorescence Reaction Cuvette20mm8000μl24x24x22mm
20mm Fused Quartz Fluorescence Reaction Cuvette Cell
ModelDescriptionPath
Length
VolumeOutline Dimension
AT-BSM-601120mm Fused Quartz Fluorescence Reaction Cuvette Cell20mm16000μl24x24x42mm
20mm Quartz Fluorescence Reaction Cuvette
ModelDescriptionPath
Length
VolumeOutline Dimension
AT-BSM-6006-130mm Quartz Fluorescence Reaction Cuvette30mm27000μl34x34x32mm
20mm Quartz Fluorescence Reaction Cuvette
ModelDescriptionPath
Length
VolumeOutline Dimension
AT-BSM-6006-240mm Quartz Fluorescence Reaction Cuvette40mm64000μl44x44x42mm
20mm Quartz Fluorescence Reaction Cuvette
ModelDescriptionPath
Length
VolumeOutline Dimension
AT-BSM-6006-350mm Quartz Fluorescence Reaction Cuvette50mm125000μl54x54x52mm
50mm Quartz Fluorescence Reaction Cuvette Cell
ModelDescriptionPath
Length
VolumeOutline Dimension
AT-BSM-6006-550mm Quartz Fluorescence Reaction Cuvette Cell50mm125000μl54x54x54mm
Note: We offer custom specifications to meet your specific requirements. Contact our engineering team for consultation.

TOQUARTZ® Advanced Solutions for Precision Spectroscopy Applications with Quartz Fluorescence Reaction Cuvettes

Quartz Fluorescence Reaction Cuvette in Photodynamic Therapy (PDT) Drug Screening

In the development of photodynamic therapy (PDT) drugs, fluorescence spectroscopy is used to evaluate the photophysical properties of photosensitizers under controlled light exposure. These compounds are highly sensitive to oxygen, light, and pH, requiring sealed cuvettes with high UV-Vis transmission and chemical inertness. Traditional cuvettes often allow oxygen ingress or degrade under repeated light exposure, leading to inaccurate quantum yield measurements and photobleaching artifacts.

Key Advantages

TOQUARTZ® solution

A Canadian PDT research lab observed 18–22% fluorescence signal loss due to oxygen quenching and photobleaching in open-top cuvettes. After switching to TOQUARTZ® sealed quartz cuvettes, quantum yield measurements stabilized within ±2%, and photobleaching was reduced by 35% over 40-minute light exposure. This enabled accurate evaluation of 7 new photosensitizer candidates under ISO 10993-5 protocols.

Quartz Fluorescence Reaction Cuvette in Food Safety Fluorescence Detection

Food safety labs use fluorescence spectroscopy to detect aflatoxins and mycotoxins in grains, nuts, and dairy products. These compounds fluoresce under UV excitation, but sample matrices are often acidic, oily, or contain ethanol-based extraction solvents. Standard cuvettes suffer from chemical etching, poor sealing, or autofluorescence, which compromises detection accuracy and increases false positives.

Key Advantages

TOQUARTZ® solution

A Polish food safety lab testing aflatoxins in corn extracts reported 12% false positive rate due to cuvette autofluorescence and ethanol-induced degradation. After adopting TOQUARTZ® cuvettes, background signal dropped by 87%, and retest frequency decreased by 40%. This improved compliance with EU Regulation No. 1881/2006 for aflatoxin B1 limits (2 μg/kg).

Quartz Fluorescence Reaction Cuvette in Forensic Trace Evidence Fluorescence Analysis

In pharmaceutical formulation, fluorescence spectroscopy is used to monitor the release kinetics of encapsulated drugs (e.g., liposomes, nanoparticles) in simulated body fluids. These tests often require long-term incubation at 37°C with periodic fluorescence readings. Without a sealed cuvette, evaporation skews concentration, and contamination risks increase with repeated handling.

Key Advantages

TOQUARTZ® solution

A forensic lab in Germany analyzing dyed synthetic fibers encountered 30% signal variability due to cuvette wall scattering and sample evaporation. TOQUARTZ® cuvettes with four-sided optical polishing and screw caps improved signal-to-noise ratio by 35% and preserved sample integrity for extended analysis. This enabled successful matching of fiber evidence in a high-profile criminal investigation.

TOQUARTZ® Customization Options for Quartz Fluorescence
Reaction Cuvettes

Beyond our standard product line, TOQUARTZ® offers comprehensive customization services tailored to your specific experimental requirements and instrument specifications.

Dimensional Customization

Functional Enhancements

Custom Design Process

Usage and Care Guidelines

Proper handling and maintenance of quartz fluorescence reaction cuvettes ensures optimal performance and extends product lifespan, providing consistent results for your analytical applications.

Proper Handling & Cleaning

Storage & Maintenance

Best Practices for Optimal Performance

Need Engineering Support for Your Quartz Fluorescence Reaction Cuvette Project?

Our technical experts are available to provide guidance on material selection, design optimization, and application-specific solutions.

Why Partner with TOQUARTZ

Direct Factory Advantage

As a direct manufacturer, we can cut out the numerous intermediate links.

Engineering Expertise

Technical team guides clients from material selection to design optimization, translating specs into deliverables.

Flexible Manufacturing

Handling standard & custom orders via small-batch expertise and prototyping rigor to meet urgent deadlines.

Quality
Assurance

Pre-shipment 3-step validation:
1. dimensional accuracy,
2. material purity ,
3. performance thresholds

Global Supply Chain

Reliable global logistics to industrial hubs (DE/US/JP/KR priority) with trackable milestones.

FAQ

Q: Can the Quartz Fluorescence Reaction Cuvette be used with highly acidic or basic samples?

A: Yes, our cuvettes are chemically stable in pH 1–14 environments. The high-purity quartz resists corrosion from strong acids and bases, except hydrofluoric acid (HF), which should be strictly avoided.

A: The autofluorescence is <0.002 AU at 365nm excitation. This ensures minimal background interference in low-concentration fluorescence assays.

A: The precision screw cap prevents evaporation and contamination, especially for volatile solvents like ethanol or DMSO. It ensures consistent concentration during long assays.

A: Yes, our cuvettes are compatible with portable fluorometers. The sealed design and chemical durability make them suitable for on-site environmental or food safety testing.

A: Rinse with deionized water and spectroscopic-grade solvents. Avoid HF and ultrasonic cleaning. Store in a dust-free case to prevent scratches and contamination.

Contact our engineering team for technical consultation and pricing. We’ll help you select the optimal specifications for your application requirements.

滚动至顶部

Get a Fast Quote Now

Tell us what you need — Receive tailored pricing and lead time with 6hours.

* Check email after submit. Not received? Verify address.