Features of Quartz fluorescence cuvette with lids
TOQUARTZ® quartz fluorescence cuvettes with lids are manufactured to meet the demanding requirements of spectroscopic analysis with superior optical properties and chemical resistance.
Material Purity
Made from high-purity fused quartz (≥99.98%, max. up to 99.995% SiO₂) for exceptional chemical resistance and optical clarity, suitable for sensitive fluorescence measurements.
Sealed Design
PTFE lid provides secure sealing to prevent sample evaporation and contamination during measurement and storage.
Optical Transmission
Superior UV-visible light transmission range from 190nm to 2500nm with no absorption peaks, perfect for full-spectrum analysis.
- SiO2 Purity ≥99.98%, up to 99.995%
- Chemical Resistance to Harsh Reagents
- Customization Services Available
Technical Specifications & Dimensions of Quartz fluorescence cuvette
with lids
Technical Specifications
| Parameter | Specification |
| 1. Physical Properties | |
| Material | High-purity quartz (≥99.98%, max. up to 99.995% SiO2) |
| Density | 2.2 g/cm³ |
| Thermal Expansion Coefficient | 5.5×10-7/℃ |
| Breakage Modulus | 350MPa+ |
| Cap Material | PTFE (standard), PE (optional) |
| 2. Chemical Properties | |
| Chemical Resistance | Resistant to acids, bases, salts, and fluorinated gases |
| Alkali Resistance | Good at room temperature |
| Solvent Resistance | Excellent for all organic solvents |
| Water Absorption | < 0.001% |
| 3. Optical Properties | |
| Transmission Range | 200-2500nm |
| Refractive Index | 1.46 at 589.3nm |
| Transmission Rate | ≥80% (200-800nm) |
| Absorption Peaks | None within transmission range |
Size Chart
| Model | Description | Path Length | Volume | Outline Dimension |
| AT-BSM-6015 | 1750μl Quartz Fluorescence Cuvette Cell with Lid | 5mm | 1750μl | 7.5×12.5x45mm |
| Model | Description | Path Length | Volume | Outline Dimension |
| AT-BSM-6010 | 1750μl Quartz Fluorescence Cuvette with Lid | 10mm | 1750μl | 12.5×12.5x45mm |
| Model | Description | Path Length | Volume | Outline Dimension |
| AT-BSM-6002 | 3500μl Quartz Fluorescence Cuvette with Lid | 10mm | 3500μl | 12.5×12.5x45mm |
| Model | Description | Path Length | Volume | Outline Dimension |
| AT-BSM-6003 | 3500μl Standard Quartz Fluorescence Cuvette with Lid | 10mm | 3500μl | 12.5×12.5x45mm |
| Model | Description | Path Length | Volume | Outline Dimension |
| AT-BSM-6012 | 3500μl Quartz Fluorescence Cuvette Cell with Lid | 10mm | 3500μl | 12.5×12.5x45mm |
| Model | Description | Path Length | Volume | Outline Dimension |
| AT-BSM-6014 | 7000μl Quartz Fluorescence Cuvette Cell with Lid | 20mm | 7000μl | 12.5×22.5x45mm |
| Model | Description | Path Length | Volume | Outline Dimension |
| AT-BSM-6013 | 10500μl Quartz Fluorescence Cuvette Cell with Lid | 30mm | 10500μl | 12.5×32.5x45mm |
| Model | Description | Path Length | Volume | Outline Dimension |
| AT-BSM-6005 | 14000μl Quartz Fluorescence Cuvette with Lid Path Length 10mm | 10mm | 14000μl | 12.5×42.5x45mm |
| Model | Description | Path Length | Volume | Outline Dimension |
| AT-BSM-6005-1 | 14000μl Quartz Fluorescence Cuvette with Lid Path Length 40mm | 40mm | 14000μl | 12.5×42.5x45mm |
| Model | Description | Path Length | Volume | Outline Dimension |
| AT-BSM-6007 | 17500μl Quartz Fluorescence Cuvette with Lid Path Length 10mm | 10mm | 17500μl | 12.5×52.5x45mm |
| Model | Description | Path Length | Volume | Outline Dimension |
| AT-BSM-6007-1 | 17500μl Quartz Fluorescence Cuvette with Lid Path Length 50mm | 50mm | 17500μl | 12.5×52.5x45mm |
TOQUARTZ® Solving Challenges in Fluorescence Spectroscopy Analysis with Quartz fluorescence cuvette with lids
Quartz Fluorescence Cuvette with Lid for DNA/RNA Analysis
Key Advantages
-
Ultra-tight path length tolerance (±0.05mm)
Ensures consistent excitation volume across replicates, reducing CV to <2% in qPCR assays. -
Low-volume compatibility down to 100μL
Minimizes reagent use while maintaining fluorescence signal integrity in micro-assays. -
Four-side optical window alignment
Enables dual-axis excitation/emission for high-sensitivity nucleic acid quantification.
TOQUARTZ® solution
A genomics lab in Boston reported 8–12% signal deviation using generic cuvettes in DNA quantification. After switching to TOQUARTZ® cuvettes with ±0.05mm tolerance and 100μL compatibility, their inter-replicate CV dropped to 1.6%, improving qPCR reproducibility and reducing reagent waste by 35%. The lab now uses TOQUARTZ cuvettes as standard for all nucleic acid fluorescence workflows.
Quartz Fluorescence Cuvette with Lid for Protein Analysis
Key Advantages
-
PTFE-sealed lid with <0.5% evaporation rate over 24h
Maintains protein concentration stability during long-term kinetic fluorescence assays. -
Black masking option for stray light suppression
Reduces background noise by 18%, enhancing signal-to-noise ratio in low-abundance protein detection. -
Custom 20mm path length for low-concentration proteins
Improves detection sensitivity by 2.3× compared to standard 10mm cuvettes.
TOQUARTZ® solution
A German biotech firm faced 6% protein concentration drift in 12-hour fluorescence kinetics using open-top cuvettes. TOQUARTZ® sealed cuvettes reduced evaporation to <0.5%, maintaining sample integrity throughout the assay. With black-masked sides, background noise dropped by 18%, enabling detection of 0.2μg/mL BSA with 98% accuracy. This allowed the firm to validate protein stability protocols previously deemed unreliable.
Quartz Fluorescence Cuvette with Lid for Environmental Analysis
Key Advantages
-
Sealed lid prevents airborne particulate contamination
Reduces false positives in PAH detection by 22% in urban air quality monitoring. -
Low-autofluorescence quartz (<0.002 AU at 300nm)
Enables detection of trace-level contaminants down to 0.05 ppb with minimal background interference. -
Anti-leaching PTFE cap certified for VOC testing
Ensures no organic interference in volatile compound analysis over 48h storage.
TOQUARTZ® solution
A Tokyo-based environmental lab struggled with inconsistent PAH readings due to sample contamination. Switching to TOQUARTZ® sealed cuvettes reduced airborne particle interference, improving detection repeatability by 27%. Low-autofluorescence quartz enabled reliable quantification of benzo[a]pyrene at 0.04 ppb. The lab now uses TOQUARTZ cuvettes for all trace organic pollutant fluorescence assays.
TOQUARTZ® Customization Options for Quartz fluorescence cuvette
with lids
Dimensional Customization
-
Custom Dimensions:
Non-standard path lengths, heights, and widths to match your specific instrument requirements. -
Specialized Lid Types:
Different cap designs including screw caps, stoppers, and custom sealing mechanisms for specific applications. -
Surface Treatments:
Frosted walls, black masks, and specialized coatings to enhance signal-to-noise ratio in your measurements. -
Small Volume Solutions:
Micro-volume designs for precious samples, with volumes as low as 100μL while maintaining measurement accuracy.
Material and Finish Options
-
Requirement Collection:
We begin by gathering detailed specifications and application needs for your Quartz Fluorescence Cuvette with Lid. -
Technical Evaluation:
Our engineers assess feasibility and tolerances based on your Quartz Fluorescence Cuvette with Lid design or sample. -
Drawing Confirmation:
We provide or validate technical drawings to ensure dimensional accuracy of the Quartz Fluorescence Cuvette with Lid. -
Prototype Sampling:
A sample Quartz Fluorescence Cuvette with Lid is produced for testing before mass production begins.
Usage and Care Guidelines
Handling Instructions
-
Always handle with gloves:
Fingerprints can affect optical performance and measurement accuracy. -
Hold by non-optical surfaces:
Avoid touching the clear optical windows to prevent contamination. -
Secure lid properly:
Ensure the PTFE lid is securely in place to prevent evaporation and contamination. -
Avoid rapid temperature changes:
Gradual temperature transitions prevent thermal stress and potential damage.
Cleaning and Maintenance
-
Clean immediately after use:
Prevents sample residue from drying and becoming difficult to remove. -
Use appropriate solvents:
Start with mild detergents, followed by distilled water. Use acetone or ethanol for stubborn residues. -
Air dry or use lint-free cloth:
Never use abrasive materials or paper towels, which can scratch the optical surfaces. -
Store in protective case:
When not in use, store cuvettes in their original packaging or a dedicated dust-free container.
Tips for Optimal Measurements
- Ensure cuvette is properly oriented in the instrument with optical windows facing the light path.
- Allow samples to reach room temperature before measurement to prevent condensation.
- Use the same cuvette for all measurements in a series to maintain consistency.
- Avoid air bubbles by gently tapping the cuvette before measurement.
- Fill to the appropriate volume - usually 80-90% of capacity is optimal.
- Establish a baseline with the same buffer or solvent used in your samples.
Need a custom quartz fluorescence cuvette solution?
Send us your requirements or existing drawings for a prompt quotation.
Why Partner with TOQUARTZ
Direct Factory Advantage
As a direct manufacturer, we can cut out the numerous intermediate links.
Engineering Expertise
Technical team guides clients from material selection to design optimization, translating specs into deliverables.
Flexible Manufacturing
Handling standard & custom orders via small-batch expertise and prototyping rigor to meet urgent deadlines.
Quality
Assurance
Pre-shipment 3-step validation:
1. dimensional accuracy,
2. material purity ,
3. performance thresholds
Global Supply Chain
Reliable global logistics to industrial hubs (DE/US/JP/KR priority) with trackable milestones.
Releted Products
As a specialized manufacturer with direct factory capabilities, TOQUARTZ provides both standard and custom quartz solutions with engineering support throughout the specification and implementation process.
FAQ
Q: Why is a sealed lid important in a Quartz Fluorescence Cuvette with Lid for fluorescence spectroscopy?
A: The sealed lid prevents sample evaporation and contamination, which is critical for maintaining consistent fluorescence intensity during long-duration or kinetic assays.
Q: Can the Quartz Fluorescence Cuvette with Lid be used for volatile or light-sensitive samples?
A: Yes, the PTFE lid on the Quartz Fluorescence Cuvette with Lid provides a chemically inert and light-blocking seal, ideal for volatile or photosensitive compounds.
Q: How does the lid design affect measurement accuracy in a Quartz Fluorescence Cuvette with Lid?
A: The lid ensures a stable sample volume and prevents air exchange, reducing signal drift and improving reproducibility in fluorescence measurements.
Q: What is the evaporation rate of samples in a Quartz Fluorescence Cuvette with Lid during long assays?
A: With the PTFE lid properly sealed, evaporation is reduced to less than 0.5% over 24 hours, ensuring stable fluorescence signal in kinetic studies.
Q: How does the lid design impact the cleaning and reuse of the Quartz Fluorescence Cuvette with Lid?
A: The lid is removable and chemically resistant, allowing for easy cleaning and reuse without compromising the cuvette’s sealing performance.