1. Home
  2. /
  3. Types
  4. /
  5. Quartz Cuvette
  6. /
  7. Quartz Flow-Through Cuvette
  8. /
  9. Flow-Optimized Quartz Flow Cell...

Flow-Optimized Quartz Flow Cell Counting Cuvettes for Analytical Chemistry-TOQUARTZ®

TOQUARTZ® Quartz Flow Cell Counting Cuvette is engineered from fused quartz (≥ 99.98%, up to 99.995% SiO₂), delivering stable optical transmission from 190–2500 nm with no absorption peaks. Designed for high-throughput laboratories, it supports spectrophotometry, fluorescence assays, and continuous particle counting applications.
No MOQ
Custom Design
Factory Direct
Tech Support

Features of Quartz Flow Cell Counting Cuvettes

TOQUARTZ® Quartz Flow Cell Counting Cuvette delivers high optical accuracy, strong chemical resistance, and reliable performance for laboratories and industrial users who demand consistency in spectrophotometry, fluorescence, and particle counting.

Chemical and Thermal Stability

High Optical Precision

Practical Design Benefits

Inline-Compatible Quartz Flow Cell Counting Cuvettes for Analytical Chemistry
TOQUARTZ® Quartz Flow Cell Counting Cuvettes

Technical Specifications & Dimensions of Quartz Flow Cell Counting Cuvettes

TOQUARTZ® Transparent Quartz Fluorescence Flow Cuvette Cell with PTFE M10 Screw Cap is engineered with defined physical, chemical, optical, and mechanical properties to meet laboratory and diagnostic system requirements.

Technical Specifications

Property (Dimension)Specification (Data)
Physical PropertiesDensity: 2.2 g/cm3;
Softening Point: 1680°C;
Thermal Expansion: ≤0.55×10-6/K;
Thermal Conductivity: 120–160W/m·K;
Service Temperature: up to 1100°C
Chemical PropertiesSiO2 Purity: ≥99.98%;
Acid Resistance: stable in HCl/H2SO4;
Alkali Resistance: stable up to 1N NaOH;
Gas Stability: resistant to fluorinated gases;
Solvent Compatibility: stable against most organics
Optical PropertiesTransmission Range: 190–2500nm;
Transmittance Deviation: ≤0.3%;
Absorption Peaks: none;
Refractive Index (589 nm): 1.46;
Birefringence: ≤5 nm/cm
Mechanical PropertiesFracture Modulus: ≥350MPa;
Compressive Strength: ≥1100MPa;
Bending Strength: ≥70MPa;
Young’s Modulus: 72GPa;
Hardness (Mohs): 6.5
Electrical PropertiesDielectric Strength: 250–400 kV/cm;
Dielectric Constant (1 MHz): 3.8;
Loss Tangent (1 MHz): <0.0002

Size Chart

16μl Quartz Flow Cell Counting Cuvette
ModelDescriptionPath
Length
VolumeOutline Dimension
AT-BSM-802516μl Quartz Flow Cell Counting Cuvette0.2mm16μl30x15x4mm
Quartz Flow Cell Counting Cuvette 0.2mm Path Length
ModelDescriptionPath
Length
WindowsOutline Dimension
AT-BSM-8025-1Quartz Flow Cell Counting Cuvette 0.2mm Path Length0.2mm230x15x3.7mm
Quartz Flow Cell Counting Cuvette 2mm Path Length
ModelDescriptionPath
Length
VolumeOutline Dimension
AT-BSM-8029-1Quartz Flow Cell Counting Cuvette 2mm Path Length2mm/60x35x3mm
Quartz Flow Cell Counting Cuvette 2 optical windows
ModelDescriptionPath
Length
WindowsOutline Dimension
AT-BSM-8025-2Quartz Flow Cell Counting Cuvette 2 optical windows5mm232x17x8.5mm
Quartz Flow Cell Counting Cuvette 5mm Path Length
ModelDescriptionPath
Length
VolumeOutline Dimension
AT-BSM-8029Quartz Flow Cell Counting Cuvette 5mm Path Length5mm/60x35x7mm
Note: We offer custom specifications to meet your specific requirements. Contact our engineering team for consultation.

TOQUARTZ® Solving Challenges in Spectroscopic Analysis with Quartz Flow Cell Counting Cuvettes

Quartz Flow Cell Counting Cuvette in Hematology and Biochemistry Analyzers

Automated hematology and biochemistry analyzers run thousands of assays each day and rely on precise light transmission through small-volume samples. If cuvettes lose clarity or fail under chemical exposure, results can drift outside acceptable limits and require costly retesting. Reagent residues often corrode plastic chambers, shortening their usable life and disrupting workflow. Laboratories face both higher operating costs and longer downtime when measurement stability cannot be maintained.

Key Advantages

TOQUARTZ® solution

A European clinical lab reported that plastic cuvettes corroded after 6 months, raising retest rates by nearly 12% and adding €15,000 in reagent costs annually. After switching to TOQUARTZ® Quartz Flow Cell Counting Cuvette, the lab maintained stable operation for over a year without performance loss. Retest rates dropped below 2%, and throughput increased by 18%, directly lowering analyzer downtime and cost per assay.

Quartz Flow Cell Counting Cuvette in Inline Chromatography Detection

Chromatography instruments demand consistent optical pathways to monitor analyte peaks in real time. Even minor leaks or optical misalignment in the flow cell can distort peak shapes, reducing data accuracy and reliability. High-pressure operation puts stress on standard flow chambers, leading to seal failures or clouded windows that affect spectral clarity. Analytical labs require durable cuvettes that integrate seamlessly with tubing systems to maintain throughput and reduce instrument downtime.

Key Advantages

TOQUARTZ® solution

A US pharmaceutical QC lab experienced inconsistent chromatogram peaks due to seal failures in polymer cells, causing 1 in 20 runs to be invalidated. With TOQUARTZ® Quartz Flow Cell Counting Cuvette, the lab achieved 100% run completion over 3 months of continuous HPLC testing. Downtime decreased by 22 hours per month, and validation data consistency improved, supporting FDA audit compliance without additional corrective testing.

Quartz Flow Cell Counting Cuvette in Fuel and Lubricant Quality Testing

Petrochemical testing facilities measure clarity and particulate levels in fuels and lubricants under continuous flow conditions. Polymer-based cuvettes frequently degrade when exposed to hydrocarbons, causing spectral interference and forcing repeat measurements. High-viscosity samples also place stress on cell chambers, leading to premature cracking or seal failures. Inconsistent results raise the risk of non-compliance with ASTM or ISO testing standards, which directly impacts production timelines and customer trust.

Key Advantages

TOQUARTZ® solution

A Middle Eastern refinery lab using polymer cuvettes faced frequent spectral interference after 200 hours of diesel analysis, leading to 15% repeat testing rates and significant compliance risks. After adopting TOQUARTZ® Quartz Flow Cell Counting Cuvette, repeat tests dropped to under 3%, and each cuvette lasted for more than 1,000 test hours without structural degradation. This improved regulatory compliance and cut downtime by nearly 40%, directly reducing per-sample testing costs.

Customization Solutions for Your Specific Applications

TOQUARTZ® provides tailored customization options for the Quartz Flow Cell Counting Cuvette, allowing laboratories and manufacturers to meet specific analytical, structural, and operational requirements with precision-engineered designs.

Material and Surface Adjustments

Material and surface modifications enhance durability and optical stability of the Quartz Flow Cell Counting Cuvette in demanding environments.

Optical Path Customization

Adjusting the optical path of the Quartz Flow Cell Counting Cuvette ensures accurate light interaction for specialized analysis.

Chamber Geometry Variations

Chamber customization allows the Quartz Flow Cell Counting Cuvette to handle different sample types and volumes effectively.

Connector and Interface Options

Connector customization enables the Quartz Flow Cell Counting Cuvette to integrate seamlessly into diverse analytical systems.

Product Usage Guideline

The Quartz Flow Cell Counting Cuvette requires proper handling to ensure long service life and reliable results. This guide covers daily operation, cleaning steps, storage methods, and troubleshooting practices for laboratories and industrial users.

Operating Instructions

Cleaning and Maintenance

Storage Recommendations

Troubleshooting Guide

Advance Accuracy with Quartz Flow Cell Counting Cuvette

Our engineering support helps you overcome measurement challenges and maintain reliable laboratory performance.
Reach out for customized technical guidance.

Why Partner with TOQUARTZ

Direct Factory Advantage

As a direct manufacturer, we can cut out the numerous intermediate links.

Engineering Expertise

Technical team guides clients from material selection to design optimization, translating specs into deliverables.

Flexible Manufacturing

Handling standard & custom orders via small-batch expertise and prototyping rigor to meet urgent deadlines.

Quality
Assurance

Pre-shipment 3-step validation:
1. dimensional accuracy,
2. material purity ,
3. performance thresholds

Global Supply Chain

Reliable global logistics to industrial hubs (DE/US/JP/KR priority) with trackable milestones.

FAQ

Q: How does the transparent wall of the Quartz Flow Cell Counting Cuvette improve analytical accuracy?

A: The transparent wall provides clear optical pathways for UV–VIS–NIR measurements, reducing background interference in assays. This ensures stable signal detection across multiple wavelengths. For applications like DNA quantification, the transparent wall of the Quartz Flow Cell Counting Cuvette guarantees reproducible results with minimal deviation.

A: The flow-through design enables continuous sample measurement, avoiding interruptions during high-throughput analysis. It reduces dead volume and allows faster fluid exchange, minimizing carry-over between samples. For automated analyzers, the Quartz Flow Cell Counting Cuvette streamlines workflows and reduces operational downtime.

A: Yes, the fused quartz body is stable against strong acids, bases, and organic solvents commonly used in diagnostic labs. This ensures durability even after hundreds of test cycles. Users benefit from consistent performance when the Quartz Flow Cell Counting Cuvette is exposed to aggressive reagents.

A: Its flow chamber is designed to manage microliter volumes without significant evaporation or loss. This precision is critical for expensive reagents and small biological samples. In life science research, the Quartz Flow Cell Counting Cuvette ensures reliable measurements from limited sample material.

A: The transparent quartz provides high transmission from 190–2500 nm, which covers excitation and emission ranges. This allows accurate fluorescence detection without optical distortion. The Quartz Flow Cell Counting Cuvette therefore enhances sensitivity in fluorescence-based assays.

Contact our engineering team for technical consultation and pricing. We’ll help you select the optimal specifications for your application requirements.

en_USEnglish
滚动至顶部

Get a Fast Quote Now

Tell us what you need — Receive tailored pricing and lead time with 6hours.

* Check email after submit. Not received? Verify address.