- Home
- /
- Types
- /
- Quartz Cuvette
- /
- Quartz Flow-Through Cuvette
- /
- Quartz Black Wall Fluorescence...
Quartz Black Wall Fluorescence Flow Cell with M6 Threaded Connectors for Analytical Systems -TOQUARTZ®
Features of Quartz Black Wall Fluorescence Flow Cell with
M6 Threaded Connectors
The TOQUARTZ® Quartz Black Wall Fluorescence Flow Cell combines precision engineering with high-quality materials to deliver superior optical performance for analytical applications. Each component is designed to meet the demands of sensitive fluorescence detection while ensuring durability and ease of integration.
High-Purity Quartz Material
Manufactured from JGS-1 imported quartz with ≥ 99.98% (up to 99.995%) SiO₂ purity, ensuring minimal contamination and superior optical properties for precise analytical measurements.
Black Inner Wall Design
Specialized black inner walls minimize stray light and light scattering, significantly enhancing signal-to-noise ratio for fluorescence measurements and improving detection sensitivity.
Dual Optical Windows
Precision-polished dual optical windows with ≤ 0.3% transmittance deviation provide clear optical paths for accurate spectroscopic analysis across UV-Visible-Fluorescence applications.
M6 Threaded Connector
Integrated M6 threaded connectors allow secure, leak-free integration with pump systems, manifolds, and analytical instruments, simplifying installation and ensuring system integrity.
M6 Threaded Connectors
- SiO2 Purity ≥99.98%, up to 99.995%
- Chemical Resistance to Harsh Reagents
- Customization Services Available
Technical Specifications & Dimensions of Quartz Black Wall Fluorescence Flow Cell with M6 Threaded Connectors
Technical Specifications
| Parameter | Specification |
| 1. Physical Properties | |
| Material: | High-purity quartz, stainless steel |
| Quartz Purity: | ≥99.98%, up to 99.995% SiO2 |
| Operating Temperature: | Up to 1100°C |
| Thermal Expansion: | 5.5 × 10-7/°C (20-320°C) |
| Surface Finish: | Optical grade polished |
| 2. Chemical Properties | |
| Chemical Resistance: | Excellent |
| Acid Resistance: | High (except HF) |
| Alkali Resistance: | Good at room temperature |
| Solvent Compatibility: | Compatible with most organics |
| Water Absorption: | Nil |
| 3. Optical Properties | |
| UV Transmission Range: | 190-2500 nm |
| Refractive Index: | 1.458 (at 546.1nm) |
| UV Cutoff: | 170 nm |
| Transparency: | ≥90% (200-2000 nm) |
| Surface Quality: | 60-40 scratch-dig |
Size Chart
| Model | Description | Path Length | Volume | Outline Dimension |
| AT-BSM-8011-1 | 70μl Quartz Black Wall Fluorescence Flow Cell with M6 Threaded Connector | 10mm | 70μl | 12.5×12.5x35mm |
| Model | Description | Path Length | Volume | Outline Dimension |
| AT-BSM-8011 | 450μl Quartz Black Wall Fluorescence Flow Cell with M6 Threaded Connector | 10mm | 450μl | 12.5×12.5x35mm |
Solving Analytical Challenges with TOQUARTZ® Quartz Black Wall Fluorescence Flow Cell with M6 Threaded Connectors
Fluorescence Assays in Microfluidic Bioanalysis
Key Advantages
-
Signal-to-Noise Ratio:
Black wall design improves SNR by up to 28% compared with clear cells in DNA fluorescence assays. -
Leak-Free Integration:
Precision M6 threads tested for 0% leakage in 500+ connection cycles with peristaltic pumps. -
Low Sample Volume:
70 μL channel validated to reduce sample consumption by 45% in protein kinetic studies.
TOQUARTZ® solution
A European microfluidics lab using fluorescently labeled DNA reported unstable signals with standard clear flow cells due to stray light and frequent connector leaks. After switching to TOQUARTZ Quartz Black Wall Fluorescence Flow Cell with M6 Threaded Connector, the lab achieved a 27% improvement in detection sensitivity and eliminated leakage over 6 months of continuous operation, enabling reliable quantification of low-abundance nucleic acids.
Pharmaceutical Dissolution and Drug Stability Testing
Key Advantages
-
Pressure Resistance:
M6 connectors withstand 1.5 MPa pressure with zero leakage in 48-hour dissolution tests. -
Volume Precision:
Internal volume deviation reduced to <2% across 10 production batches, ensuring curve reproducibility. -
Background Reduction:
Black wall reduces solvent-induced fluorescence baseline drift by 22% in buffer-switching assays.
TOQUARTZ® solution
A U.S. pharmaceutical QC facility experienced 14% failure rates in dissolution curve reproducibility using conventional flow cells due to leakage and background interference. With TOQUARTZ Quartz Black Wall Fluorescence Flow Cell with M6 Threaded Connector, they achieved stable performance across 120 consecutive stability runs, cutting repeat tests to under 2% and reducing QC delays by an estimated 9 working days per quarter.
Chemical Process Monitoring in Industrial R&D
Key Advantages
-
Real-Time Accuracy:
Black wall reduces stray light error by 31% during fluorescence monitoring of catalytic intermediates. -
Sealing Integrity:
M6 threaded joints maintained seal integrity at 1.4 MPa in pilot reactor tests for >100 hours. -
Chemical Durability:
Flow channel stability confirmed after 72-hour exposure to strong acid/base with no performance loss.
TOQUARTZ® solution
An industrial R&D team monitoring polymerization intermediates faced inconsistent fluorescence readings and seal failures with clear-wall cells. After adopting TOQUARTZ Quartz Black Wall Fluorescence Flow Cell with M6 Threaded Connector, they recorded stable reaction kinetics with a 30% improvement in measurement precision and zero seal failures during 100+ hours of continuous high-pressure flow, accelerating process validation by two weeks.
TOQUARTZ® Customization Services for Quartz Black Wall Fluorescence Flow Cell with M6 Threaded Connector
Dimensional Adjustments
Customized geometry ensures compatibility with specialized analytical configurations.
-
Path Length:
Flexible channel length supports unique optical requirements. -
Internal Volume:
Adjusted cavity ensures precise sample handling accuracy. -
Outer Size:
Modified cell body fits restricted instrument chambers.
Connector Adaptations
Tailored fittings deliver secure integration with diverse flow systems.
-
Thread Options:
Alternative connectors provide stable leak-free performance. -
Spacing Control:
Adjusted distance ensures alignment with manifold ports. -
Interface Match:
Compatible fittings guarantee smooth OEM instrument integration.
Material Enhancements
Specialized material options address unique optical and chemical challenges.
-
Surface Coating:
Applied layer improves light transmission consistency. -
Wall Material:
Enhanced composition reduces unwanted background interference. -
Optical Finish:
High-grade polishing delivers superior fluorescence accuracy.
Usage and Care Guidelines
Installation & Connection
- Hand-tighten M6 connectors only - avoid using tools that may damage threads or quartz material
- Use PTFE tape on threaded connections for enhanced sealing if necessary
- Ensure flow direction follows manufacturer's arrow indicators on the cell body
- Mount cell securely in instrument holder to prevent stress on connection tubing
Cleaning & Maintenance
- Flush with suitable solvent immediately after use to prevent residue buildup
- For persistent residues, flow 5% laboratory detergent solution followed by thorough water rinse
- Avoid using ultrasonic cleaning methods which may damage optical surfaces
- Never use hydrofluoric acid (HF) which will damage quartz material
Storage & Handling
- Store flow cell filled with pure water or appropriate storage solution
- Cap all openings to prevent dust contamination during storage
- Handle cell by body only, avoid touching optical windows
- Do not exceed 1.5 MPa pressure in flow system
- Avoid rapid temperature changes which may cause thermal stress
- Do not use abrasive materials to clean optical surfaces
Need Expert Guidance on Quartz Black Wall Fluorescence Flow Cell Selection?
Why Partner with TOQUARTZ
Direct Factory Advantage
As a direct manufacturer, we can cut out the numerous intermediate links.
Engineering Expertise
Technical team guides clients from material selection to design optimization, translating specs into deliverables.
Flexible Manufacturing
Handling standard & custom orders via small-batch expertise and prototyping rigor to meet urgent deadlines.
Quality
Assurance
Pre-shipment 3-step validation:
1. dimensional accuracy,
2. material purity ,
3. performance thresholds
Global Supply Chain
Reliable global logistics to industrial hubs (DE/US/JP/KR priority) with trackable milestones.
Releted Products
As a specialized manufacturer with direct factory capabilities, TOQUARTZ provides both standard and custom quartz solutions with engineering support throughout the specification and implementation process.
FAQ
Q: Why is the black wall design important in the Quartz Black Wall Fluorescence Flow Cell with M6 Threaded Connector?
A: The black wall absorbs stray excitation light that typically reduces signal clarity in fluorescence assays. By suppressing background noise, the cell improves signal-to-noise ratio and enhances detection sensitivity. This makes the Quartz Black Wall Fluorescence Flow Cell with M6 Threaded Connector particularly effective for low-concentration fluorescence measurements.
Q: How do the M6 threaded connectors benefit fluorescence analysis applications?
A: The M6 threaded connectors ensure leak-free integration with pump systems and analytical manifolds. This stability is critical in fluorescence analysis, where inconsistent flow paths can cause data variability. With the Quartz Black Wall Fluorescence Flow Cell with M6 Threaded Connector, users achieve reliable performance during continuous flow assays.
Q: Can the Quartz Black Wall Fluorescence Flow Cell with M6 Threaded Connector handle high-pressure flow conditions?
A: Yes, the M6 threaded fittings are engineered to withstand up to 1.5 MPa without leakage. This makes it suitable for fluorescence assays in HPLC-linked or continuous flow systems. The Quartz Black Wall Fluorescence Flow Cell with M6 Threaded Connector maintains optical stability even under demanding flow conditions.
Q: How does this flow cell improve reproducibility in fluorescence assays?
A: Clear-wall cells often introduce optical interference that lowers reproducibility in quantitative assays. The black wall eliminates much of this variability, giving more stable fluorescence signals. As a result, the Quartz Black Wall Fluorescence Flow Cell with M6 Threaded Connector improves consistency across repeated measurements.
Q: How does this flow cell support trace-level fluorescence detection?
A: By eliminating stray light and maintaining a stable optical path, it lowers the detection limit for trace analytes. This is especially useful in biomarker or contaminant monitoring at very low concentrations. The Quartz Black Wall Fluorescence Flow Cell with M6 Threaded Connector is engineered for high-sensitivity assays.
Contact our engineering team for technical consultation and pricing. We’ll help you select the optimal specifications for your application requirements.