- Home
- /
- Types
- /
- Quartz Cuvette
- /
- Quartz UV Cuvette
- /
- Precision-Fit Custom-Slot Quartz UV...
Precision-Fit Custom-Slot Quartz UV Cuvette for Spectrophotometry Instruments -TOQUARTZ®
Features of Custom-Slot Quartz UV Cuvette
TOQUARTZ® Custom-Slot Quartz UV Cuvette combines premium optical performance with precision engineering to meet the demanding requirements of modern analytical instruments. Manufactured from high-purity fused quartz, these cuvettes deliver exceptional optical, thermal, and chemical properties for accurate UV-Vis spectroscopy and fluorescence analysis.
High-Purity Material
Manufactured from 99.98% SiO₂ fused quartz for minimal interference with sample analysis
Optical Properties
Exceptional transmittance (>80% at 200nm) across the 200-2500nm range with no absorption peaks in the critical UV spectrum
Custom Slot Design
Engineered to exact specifications for specialized analytical applications and instrument compatibility
Chemical Resistance
Stable against most acids, bases, and organic solvents for broad application flexibility

- Transmittance (>80% at 200nm)
- Low thermal expansion coefficient (5.5×10⁻⁷ /°C)
- Tight dimensional tolerances (±0.1mm)
Technical Specifications & Dimensions of Custom-Slot Quartz UV Cuvette
Technical Specifications
Property | Value |
1. Physical Properties | |
Material | High-purity fused quartz |
Density | 2.20 g/cm3 |
Thermal Expansion | 5.5×10-7/K |
Max Operating Temp | 1100℃ |
Hardness | 5.5-6.5 Mohs |
2. Chemical Properties | |
SiO₂ Content | ≥99.98% |
Chemical Resistance | Excellent to acids, bases, salts |
Water Absorption | <0.01% |
Solubility in Water | Negligible |
3. Optical Properties | |
Refractive Index | 1.458 (at 546nm) |
UV Cutoff | <180nm |
Transmittance (200nm) | >80% |
Transmittance (250-2500nm) | >90% |
Surface Quality | Fine optical polish |
Size Chart

Model | Description | Wavelength | Path Length | Volume | Transmittance | Outline Dimension |
AT-BSM-030 | Custom-Slot Quartz UV Cuvette | 200nm-2500nm | 2mm/0.5mm | / | >80% (Paired Testing) | 35x5x42mm |
TOQUARTZ® Solving Challenges with Custom-Slot Quartz UV Cuvette
Custom-Slot Quartz UV Cuvettes for Automated Spectrophotometer Systems
Key Advantages
-
Slot width tolerance within ±0.05mm
Ensures seamless insertion into auto-sampler trays with zero jamming or misalignment. -
Optical centerline deviation <0.1mm
Maintains consistent path length across batches, reducing calibration drift in automated systems. -
Dimensional repeatability >98.5% across 500-unit batches
Supports high-throughput workflows with minimal rejection rate and no manual adjustment.
TOQUARTZ® solution
A German spectrophotometer OEM reported a 17.8% rejection rate using generic cuvettes due to slot misalignment in auto-samplers. After switching to TOQUARTZ® Custom-Slot Quartz UV Cuvettes with ±0.05mm slot tolerance and <0.1mm optical deviation, rejection dropped below 1.2%. This improved assembly efficiency and reduced instrument recalibration frequency by 40%.
Custom-Slot Quartz UV Cuvettes for Micro-Volume Sample Analysis
Key Advantages
-
Minimum sample volume down to 45μL
Enables accurate analysis of scarce biological samples without dilution or waste. -
Slot geometry optimized for capillary action
Ensures uniform sample distribution and eliminates air bubble interference in low-volume assays. -
Signal-to-noise ratio improved by 2.7× vs. standard 1mL cuvettes
Enhances detection sensitivity in dilute DNA/protein solutions.
TOQUARTZ® solution
A Canadian biotech startup conducting RNA quantification faced 30% sample loss using standard 1mL cuvettes. TOQUARTZ® delivered custom-slot cuvettes with 0.5mm path length and 45μL capacity. This reduced sample usage by 85% and improved fluorescence signal stability by 2.4×, enabling reliable results from limited-volume clinical samples.
Custom-Slot Quartz UV Cuvettes for Multi-Channel Fluorescence Detection
Key Advantages
-
Dual-beam slot design with 90° emission window alignment
Maximizes excitation-emission efficiency in orthogonal fluorescence setups. -
Optical window flatness <λ/10 at 633nm
Minimizes signal distortion and ensures high-fidelity fluorescence readouts. -
Customizable 4- or 6-window configurations
Supports simultaneous multi-channel detection in high-throughput screening platforms.
TOQUARTZ® solution
A US-based fluorescence plate reader manufacturer required a 4-window cuvette for simultaneous excitation/emission at multiple angles. TOQUARTZ® delivered a custom-slot design with λ/10 flatness and 0.1mm tolerance. Compared to their previous supplier, signal intensity improved by 38%, and integration time per assay was reduced by 22%, accelerating their product launch by 5 weeks.
Customization Services for TOQUARTZ® Custom-Slot Quartz UV Cuvette
Custom Slot Dimensions
Tailor slot width, depth, and geometry to match your specific optical path requirements
Specialized Path Lengths
Custom optical path lengths from 0.1mm to 100mm with tight tolerances (±0.1mm)
Integration Features
Custom mounting features for seamless integration with your instrument design
Usage Guide of Custom-Slot Quartz UV Cuvette
Handling Procedures
- Always handle cuvettes using gloves to prevent fingerprints and contamination
- Hold cuvettes by the frosted or non-optical surfaces to avoid scratching optical windows
- Avoid placing optical surfaces directly on laboratory benches or hard surfaces
Cleaning Instructions
- Clean immediately after use to prevent sample residue from drying
- Use mild detergent solutions followed by ultrapure water rinses
- For organic residues, use appropriate solvents (acetone, ethanol) followed by thorough rinsing
- Optional ultrasonic cleaning for persistent contaminants (2-3 minutes maximum)
- Air dry in a dust-free environment or use filtered compressed air
Storage Recommendations
- Store in original protective packaging or dedicated cuvette holders
- Keep in a clean, dust-free environment
- Avoid contact between optical surfaces during storage
- Maintain at room temperature in low-humidity conditions
Performance Verification
- Periodically verify dimensional stability with precision measurement tools
- Check optical transmission using reference standards
- Inspect for scratches, chips, or contaminants before critical measurements
Accelerate your instrument development with rapid custom cuvette prototyping
discover how TOQUARTZ can enhance your analytical precision.
Why Partner with TOQUARTZ
Direct Factory Advantage
As a direct manufacturer, we can cut out the numerous intermediate links.
Engineering Expertise
Technical team guides clients from material selection to design optimization, translating specs into deliverables.
Flexible Manufacturing
Handling standard & custom orders via small-batch expertise and prototyping rigor to meet urgent deadlines.
Quality
Assurance
Pre-shipment 3-step validation:
1. dimensional accuracy,
2. material purity ,
3. performance thresholds
Global Supply Chain
Reliable global logistics to industrial hubs (DE/US/JP/KR priority) with trackable milestones.
Releted Products
As a specialized manufacturer with direct factory capabilities, TOQUARTZ provides both standard and custom quartz solutions with engineering support throughout the specification and implementation process.
FAQ
Q: What is the difference between standard UV cuvettes and custom-slot UV cuvettes?
A: Standard UV cuvettes typically have fixed dimensions and optical path configurations, while custom-slot UV cuvettes feature specially designed sample chambers optimized for specific analytical applications, automated systems, or unique optical path requirements.
Q: What wavelength range do your Custom-Slot Quartz UV Cuvettes support?
A: TOQUARTZ® Custom-Slot Quartz UV Cuvettes provide excellent transmission from 200nm to 2500nm, making them suitable for both UV and visible spectrum applications.
Q: What dimensional tolerances can you achieve for custom-slot cuvettes?
A: We typically maintain ±0.1mm tolerances for most dimensions. For certain critical dimensions, we can achieve ±0.05mm tolerances for select designs.
Q: Are your Custom-Slot Quartz UV Cuvettes compatible with dual-beam spectrophotometers?
A: Absolutely. We can design dual-path configurations with matched optical windows and centerline alignment <0.1mm for dual-beam systems.
Q: Can your custom-slot cuvettes be used in automated sample handling systems?
A: Yes, our custom-slot cuvettes are specifically designed for reliable operation in automated systems. We can design to your exact specifications to ensure proper fit and function.
Contact our engineering team for technical consultation and pricing. We’ll help you select the optimal specifications for your application requirements.