TOQUARTZ® high-purity (≥99.98%, max. up to 99.995% SiO₂) quartz fluorescence cuvette with a screw cap designed for demanding spectroscopic applications. Features excellent light transmission from 190nm to 2500nm with a standard 10mm path length. The precision-engineered screw cap ensures a tight seal for volatile or sensitive samples.
No MOQ
Custom Design
Factory Direct
Tech Support

Features of Quartz Fluorescence Cuvette with Screw Caps

TOQUARTZ® quartz fluorescence cuvettes with screw caps combine precision manufacturing with high-purity materials to deliver exceptional performance for spectroscopic applications. Each cuvette is manufactured to strict specifications to ensure consistent results in your analytical processes.

Material Properties

Precision Engineered Design

Optical Properties

Wide-Spectrum Quartz Fluorescence Cuvette with Screw Caps for Spectroscopy
TOQUARTZ® Quartz Fluorescence Cuvette with Screw Caps

Technical Specifications & Dimensions of Quartz Fluorescence Cuvette with Screw Caps

TOQUARTZ® quartz fluorescence cuvettes are manufactured to precise specifications to ensure consistent performance in your analytical applications. Below are the detailed technical parameters of our standard offerings.

Technical Specifications

ParameterSpecificationNotes
MaterialHigh-purity fused quartz≥99.98%, up to 99.995% SiO
Transmission Range190-2500nm≥80% transmittance across range
Thermal Expansion Coefficient5.5×10-7/℃Low expansion for thermal stability
Chemical ResistanceExcellentResistant to most acids, bases, and solvents
Surface FinishOptical polishFour-sided clear windows
Screw Cap MaterialPTFEChemical resistant and leak-proof

Size Chart

600μl Quartz Fluorescence Cuvette with Screw Cap Path Length 3mm
ModelDescriptionPath
Length
VolumeOutline Dimension
AT-BSM-6022600μl Quartz Fluorescence Cuvette with Screw Cap Path Length 3mm3mm600μl12.5×12.5x45mm
600μl Quartz Fluorescence Cuvette with Screw Cap Path Length 10mm
ModelDescriptionPath
Length
VolumeOutline Dimension
AT-BSM-6022-1600μl Quartz Fluorescence Cuvette with Screw Cap Path Length 10mm10mm600μl12.5×12.5x45mm
700μl Quartz Fluorescence Cuvette with Screw Cap Path Length 2mm
ModelDescriptionPath
Length
VolumeOutline Dimension
AT-BSM-6018700μl Quartz Fluorescence Cuvette with Screw Cap Path Length 2mm2mm700μl12.5×12.5x45mm
700μl Quartz Fluorescence Cuvette with Screw Cap Path Length 10mm
ModelDescriptionPath
Length
VolumeOutline Dimension
AT-BSM-6018-1700μl Quartz Fluorescence Cuvette with Screw Cap Path Length 10mm10mm700μl12.5×12.5x45mm
1750μl Quartz Fluorescence Cuvette with Screw Cap
ModelDescriptionPath
Length
VolumeOutline Dimension
AT-BSM-60171750μl Quartz Fluorescence Cuvette with Screw Cap10mm1750μl12.5×12.5x52mm
Note: We offer custom specifications to meet your specific requirements. Contact our engineering team for consultation.

TOQUARTZ® Solving Challenges in Spectroscopic Analysis with Quartz Fluorescence Cuvette with Screw Caps

Quartz Fluorescence Cuvette with Screw Cap in On-Site Forensic Toxicology Screening

In forensic toxicology, field teams often collect biological fluids (e.g., blood, urine) for fluorescence-based drug screening. These samples are highly sensitive to contamination, evaporation, and photodegradation. Traditional open-top cuvettes are impractical for field use due to leakage risks and exposure to ambient light. A sealed, portable, and chemically inert container is essential for preserving sample integrity from collection to lab analysis.

Key Advantages

TOQUARTZ® solution

A forensic field team in Poland reported 15% sample rejection due to leakage and photodegradation during roadside drug screening operations. After switching to TOQUARTZ® Quartz Fluorescence Cuvette with Screw Cap, they achieved 100% sample retention and reduced false-negative rates by 21% across 300+ field tests, enabling admissible evidence collection under ISO 17025 protocols.

Quartz Fluorescence Cuvette with Screw Cap in Anaerobic Microbial Metabolism Studies

Anaerobic bacteria and archaea are studied using fluorescence markers to track metabolic activity. These organisms are extremely sensitive to oxygen, and even brief exposure can alter metabolic pathways or kill the culture. Standard cuvettes with loose stoppers cannot maintain an oxygen-free environment. Researchers require a sealed, gas-tight cuvette that can be purged with inert gas and remain sealed during fluorescence measurement.

Key Advantages

TOQUARTZ® solution

A Japanese microbiology lab studying methanogenic archaea observed inconsistent fluorescence signals due to oxygen leakage in standard cuvettes. After adopting TOQUARTZ® Quartz Fluorescence Cuvette with Screw Cap, they maintained anaerobic conditions (<0.5% O₂) for 48 hours, improving metabolic signal stability by 35% and enabling uninterrupted kinetic tracking in 96% of trials.

Quartz Fluorescence Cuvette with Screw Cap in Controlled-Release Drug Encapsulation Testing

In pharmaceutical formulation, fluorescence spectroscopy is used to monitor the release kinetics of encapsulated drugs (e.g., liposomes, nanoparticles) in simulated body fluids. These tests often require long-term incubation at 37°C with periodic fluorescence readings. Without a sealed cuvette, evaporation skews concentration, and contamination risks increase with repeated handling.

Key Advantages

TOQUARTZ® solution

A US-based biotech firm testing liposomal doxorubicin formulations reported 12% volume loss and 3% contamination rate over 48h in open-top cuvettes. Switching to TOQUARTZ® Quartz Fluorescence Cuvette with Screw Cap eliminated evaporation and contamination, resulting in consistent release curves and a 26% improvement in batch-to-batch reproducibility across 5 formulation types.

TOQUARTZ® Customization Options for Quartz Fluorescence Cuvette with Screw Caps

Beyond our standard offerings, TOQUARTZ provides comprehensive customization services for quartz fluorescence cuvettes to meet your specific research or production requirements.

Screw Cap Customization

Dimensional Customization

Our Customization Process

Usage and Care Guidelines

Proper handling, usage, and maintenance of quartz fluorescence cuvettes ensure optimal performance and extended service life. Follow these guidelines to maximize the value of your investment.

Handling & Storage

Sample Loading

Cleaning Procedure

Extending Service Life

Need Technical Assistance?

Our engineering team is ready to support your project with expert guidance on
Quartz Fluorescence Cuvette with Screw Cap selection, customization, and integration.

Why Partner with TOQUARTZ

Direct Factory Advantage

As a direct manufacturer, we can cut out the numerous intermediate links.

Engineering Expertise

Technical team guides clients from material selection to design optimization, translating specs into deliverables.

Flexible Manufacturing

Handling standard & custom orders via small-batch expertise and prototyping rigor to meet urgent deadlines.

Quality
Assurance

Pre-shipment 3-step validation:
1. dimensional accuracy,
2. material purity ,
3. performance thresholds

Global Supply Chain

Reliable global logistics to industrial hubs (DE/US/JP/KR priority) with trackable milestones.

FAQ

Q: How does the screw cap design improve sample stability in fluorescence analysis?

A: The Quartz Fluorescence Cuvette with Screw Cap prevents evaporation and contamination during long fluorescence scans. It ensures consistent sample concentration, especially in temperature-controlled or time-sensitive assays.

A: The Quartz Fluorescence Cuvette with Screw Cap supports gas-tight sealing after nitrogen purging. It maintains anaerobic conditions for over 48 hours, enabling accurate microbial fluorescence tracking.

A: No, the cap is positioned outside the optical path. The Quartz Fluorescence Cuvette with Screw Cap features four clear optical windows for uninterrupted excitation and emission detection.

A: Yes, the Quartz Fluorescence Cuvette with Screw Cap withstands incubation at 37–60°C. The cap remains sealed during thermal cycling, ensuring accurate kinetic fluorescence readings.

A: Unlike stoppers, the screw cap ensures consistent torque-based sealing. It prevents micro-leaks and sample evaporation, especially during extended fluorescence scans or transport.