Stable Optical Transmission Cell Frosted Quartz Micro Cuvette with Lids for UV-VIS Laboratory Applications -TOQUARTZ®

TOQUARTZ® frosted quartz micro cuvette with PTFE lid is designed for high-precision UV-VIS spectrophotometry and micro-volume sample analysis. Made from high-purity quartz (≥99.98% SiO₂, max. up to 99.995%), it offers excellent optical transmission from 200nm to 2500nm, with no absorption peaks in the UV range.
Kein MOQ
Kundenspezifisches Design
Fabrik direkt
Technische Unterstützung

Features of Frosted Quartz Micro Cuvette with Lids

TOQUARTZ® frosted quartz micro cuvettes combine precision engineering with high-quality materials to deliver exceptional performance for the most demanding spectroscopic applications.

Enhanced UV-VIS Transmission Range

Covers a broad spectral range from 200nm to 2500nm with no UV absorption peaks. Ensures accurate detection of nucleic acids, proteins, and chemical compounds.

Frosted Sidewalls for Light Control

Minimizes stray light interference and internal reflection during measurement. Improves signal-to-noise ratio in low-concentration sample analysis.

Micro-Volume Sample Compatibility

Supports volumes from 350μl to 1750μl for limited or precious samples. Ideal for DNA, RNA, and protein quantification in research labs.

PTFE Lid for Sample Integrity

Provides a secure, chemical-resistant seal to prevent evaporation or contamination. Maintains sample stability during extended analysis or transport.

precision matched frosted quartz micro cuvette with lids for absorbance tests
TOQUARTZ® Frosted Quartz Micro Cuvette with Lids

Technical Specifications & Dimensions of Frosted Quartz Micro Cuvette with Lids

TOQUARTZ® frosted quartz micro cuvettes are manufactured to precise specifications to ensure consistent performance across all analytical applications.

Technische Daten

Physikalische Eigenschaften

ParameterSpezifikation
MaterialHochreiner Quarz (≥99,98% SiO2)
Lid MaterialPTFE (Polytetrafluorethylen)
Dichte2,2 g/cm³
Wärmeausdehnungskoeffizient5.5×10-7/℃
OberflächeFrosted sidewalls, polished optical faces

Chemische Eigenschaften

ParameterSpezifikation
SäurebeständigkeitAusgezeichnet (außer HF)
AlkalibeständigkeitAusgezeichnet
Lösungsmittel-KompatibilitätKompatibel mit den meisten organischen Lösungsmitteln
BiokompatibilitätInert, nicht reaktiv mit biologischen Proben

Optische Eigenschaften

ParameterSpezifikation
Übertragungsbereich200-2500nm
UV-Grenzwert<190nm
Brechungsindex1.46 bei 589.3nm

Größentabelle

350μl Frosted Quartz Micro Cuvette with Lid
ModellBeschreibungWellenlängePfad
Länge
BandThermische StabilitätUmriss Dimension
AT-BSM-4027350μl Frosted Quartz Micro Cuvette with Lid200nm-2500nm10mm350μl600℃12,5×12,5x45mm
700μl Frosted Quartz Micro Cuvette with Lid
ModellBeschreibungWellenlängePfad
Länge
BandThermische StabilitätUmriss Dimension
AT-BSM-4034700μl Frosted Quartz Micro Cuvette with Lid200nm-2500nm10mm700μl600℃12,5×12,5x45mm
1050μl Frosted Quartz Micro Cuvette with Lid
ModellBeschreibungWellenlängePfad
Länge
BandThermische StabilitätUmriss Dimension
AT-BSM-40311050μl Frosted Quartz Micro Cuvette with Lid200nm-2500nm10mm1050μl600℃12,5×12,5x45mm
1400μl Frosted Quartz Micro Cuvette with Lid
ModellBeschreibungWellenlängePfad
Länge
BandThermische StabilitätUmriss Dimension
AT-BSM-40301400μl Frosted Quartz Micro Cuvette with Lid200nm-2500nm10mm1400μl600℃12,5×12,5x45mm
1750μl Frosted Quartz Micro Cuvette with Lid
ModellBeschreibungWellenlängePfad
Länge
BandThermische StabilitätUmriss Dimension
AT-BSM-4031-11750μl Frosted Quartz Micro Cuvette with Lid200nm-2500nm10mm1750μl600℃12,5×12,5x45mm
Hinweis: Wir bieten kundenspezifische Spezifikationen an, um Ihre spezifischen Anforderungen zu erfüllen. Kontaktieren Sie unser Ingenieurteam für eine Beratung.

TOQUARTZ® Solving Critical Challenges in Spectroscopy Applications with Frosted Quartz Micro Cuvette with Lid

Trace-Level Fluorescence Detection in Environmental Pollutant Monitoring Using Frosted Quartz Micro Cuvette with Lid

In environmental labs analyzing trace pollutants like PAHs or heavy metals via fluorescence spectroscopy, even minor stray light can distort low-intensity signals. Standard clear cuvettes often introduce background noise, especially in micro-volume setups, leading to false positives or poor detection limits.

Die wichtigsten Vorteile

TOQUARTZ®-Lösung

An environmental testing lab in Poland struggled with inconsistent fluorescence readings when detecting benzo[a]pyrene at 0.3 ppb. Using standard clear cuvettes, background noise caused 22% false positive rates. After switching to TOQUARTZ® frosted quartz micro cuvettes, false positives dropped to 6%, and detection repeatability improved by 2.7× across 5 replicates.

Protein Aggregation Studies in Biopharmaceutical Formulation Using Frosted Quartz Micro Cuvette with Lid

Biopharma R&D teams often analyze protein aggregation via UV absorbance at 280nm. In micro-volume formats, light scatter from cuvette walls can mimic aggregation signals, leading to false interpretation of protein stability. Sample evaporation during thermal ramping further complicates results.

Die wichtigsten Vorteile

TOQUARTZ®-Lösung

A biopharma R&D team in South Korea observed inconsistent A280 readings during thermal stress testing of monoclonal antibodies. Using clear cuvettes, aggregation was falsely indicated in 3 out of 10 samples. After adopting TOQUARTZ® frosted quartz micro cuvettes, false aggregation signals were eliminated, and absorbance deviation dropped from 3.8% to 0.9%, enabling reliable formulation screening.

DNA Quantification in Forensic Micro-Sample Analysis Using Frosted Quartz Micro Cuvette with Lid

Forensic labs often work with degraded or trace DNA samples. UV absorbance at 260nm requires high signal clarity, but standard cuvettes introduce optical noise in low-volume samples. Additionally, sample loss due to evaporation can compromise irreplaceable evidence.

Die wichtigsten Vorteile

TOQUARTZ®-Lösung

A forensic lab in Ontario, Canada, faced challenges quantifying degraded DNA from 15-year-old evidence. Standard cuvettes introduced noise that masked low-concentration signals. After switching to TOQUARTZ® frosted quartz micro cuvettes, signal clarity improved significantly, enabling successful quantification at 5ng/μl with 96% confidence, and reducing sample reprocessing by 40%.

TOQUARTZ® Customization Options for Frosted Quartz Micro Cuvette
with Lids

TOQUARTZ® offers specialized customization options for our frosted quartz micro cuvettes to meet your specific application requirements.

Volume Customization

Modifikationen der Abmessungen

Specialized Lid Options

Usage Guide of Frosted Quartz Micro Cuvette with Lids

Follow these guidelines to maximize the performance and lifespan of your TOQUARTZ frosted quartz micro cuvettes, ensuring consistent results and longevity.

Richtige Handhabung

Probe laden

Verfahren zur Reinigung

Empfehlungen zur Lagerung

Benötigen Sie technische Unterstützung?

Our engineers are available to provide free project consultation for your Frosted Quartz Micro Cuvette with Lid Anwendungen.
Get expert advice on material selection, dimensions, and specifications.

Warum eine Partnerschaft mit TOQUARTZ

Vorteil der direkten Fabrik

Als direkter Hersteller können wir die zahlreichen Zwischenstufen ausschalten.

Technische Kompetenz

Das technische Team begleitet die Kunden von der Materialauswahl bis zur Designoptimierung und setzt die Spezifikationen in Ergebnisse um.

Flexible Fertigung

Bearbeitung von Standard- und kundenspezifischen Aufträgen mit Hilfe von Kleinserien und Prototyping, um dringende Fristen einzuhalten.

Qualität
Versicherung

3-Stufen-Validierung vor dem Versand:
1. Maßhaltigkeit,
2. Materialreinheit ,
3. Leistungsschwellen

Globale Lieferkette

Zuverlässige globale Logistik zu den industriellen Zentren (Priorität DE/US/JP/KR) mit nachvollziehbaren Meilensteinen.

FAQ

Q: Why does the Frosted Quartz Micro Cuvette with Lid have frosted sidewalls instead of fully transparent walls?

A: The frosted sidewalls in the Frosted Quartz Micro Cuvette with Lid are designed to suppress stray light and reduce internal reflections, which is critical for improving signal-to-noise ratio in micro-volume UV-VIS and fluorescence measurements.

A: No. The optical windows remain fully polished for accurate light transmission. The frosted areas are only on the sidewalls, outside the light path, and do not interfere with measurement accuracy.

A: The PTFE lid maintains a tight seal under temperature changes, reducing evaporation by over 85% during thermal ramping in protein or DNA stability studies.

A: No. The frosted walls are outside the optical path and do not interfere with baseline correction. In fact, they help stabilize the baseline by reducing stray light interference.

A: Yes. The frosted design enhances signal clarity at 260nm, and the lid prevents evaporation, making the Frosted Quartz Micro Cuvette with Lid ideal for forensic or trace DNA quantification.

Wenden Sie sich für technische Beratung und Preisgestaltung an unser Ingenieurteam. Wir helfen Ihnen bei der Auswahl der optimalen Spezifikationen für Ihre Anwendungsanforderungen.

de_DEDeutsch
Nach oben blättern

Jetzt ein schnelles Angebot anfordern

Sagen Sie uns, was Sie brauchen - Sie erhalten maßgeschneiderte Preise und Vorlaufzeiten innerhalb von 6 Stunden.

* Prüfen Sie die E-Mail nach dem Absenden. Nicht erhalten? Überprüfen Sie die Adresse.