1. Startseite
  2. /
  3. Typen
  4. /
  5. Quarz-Küvette
  6. /
  7. Quarz-Fluoreszenz-Küvette
  8. /
  9. Reflection-Minimized Triangular Quartz Fluorescence...

Reflection-Minimized Triangular Quartz Fluorescence Cuvettes for Lab Fluorometry -TOQUARTZ®

TOQUARTZ® high-purity (≥99.98%, up to 99.995% SiO₂) triangular quartz cuvette designed for precision spectroscopy applications. Featuring excellent transmission across 200-2500nm wavelength range with no absorption peaks in UV spectrum. Ideal for research laboratories requiring superior optical performance and durability.
Kein MOQ
Kundenspezifisches Design
Fabrik direkt
Technische Unterstützung

Features of Triangular Quartz Fluorescence Cuvettes

TOQUARTZ® triangular quartz cuvettes are manufactured using high-grade optical quartz material, delivering exceptional performance for demanding spectroscopy applications. Each cuvette is precision-crafted to meet rigorous laboratory standards.

Optische Eigenschaften

Made from high-purity quartz (≥99.98%, up to 99.995% SiO₂) with excellent transmission across 200-2500nm wavelength range, ideal for UV-Vis and fluorescence spectroscopy applications.

Chemische Beständigkeit

Optimized triangular geometry provides consistent optical path and minimizes reflections. Precision-ground and polished surfaces ensure accurate and reproducible spectroscopic measurements.

Chemische Beständigkeit

Exceptional resistance to acids, bases, and salt solutions. Remains stable when exposed to fluorine gas and various corrosive chemicals commonly used in laboratory environments.

Signal-Enhanced Triangular Quartz Fluorescence Cuvettes for Molecular Research
TOQUARTZ® Triangular Quartz Fluorescence Cuvettes

Technical Specifications & Dimensions of Triangular Quartz
Fluoreszenz-Küvetten

TOQUARTZ® triangular quartz fluorescence cuvettes are manufactured to precise specifications, ensuring consistent performance for spectroscopic applications. Each cuvette undergoes rigorous quality control testing before shipment.

Technische Daten

EigentumSpezifikation
1. Physikalische Eigenschaften
MaterialHigh-purity quartz (≥99.98%, up to 99.995% SiO₂)
OberflächePrecision polished, bubble-free, scratch-free
Mechanische FestigkeitBreaking modulus >350MPa
Wärmeausdehnungskoeffizient5.5×10-7/℃
2. Chemische Eigenschaften
Chemische ZusammensetzungSiO₂ ≥99.98% (up to 99.995%)
SäurebeständigkeitExcellent resistance to all acids except HF
AlkalibeständigkeitStable in most alkali solutions at room temperature
Lösungsmittel-KompatibilitätCompatible with organic solvents and aqueous solutions
3. Optische Eigenschaften
Übertragungsbereich190nm – 4500nm
UV-Grenzwert~170nm
Brechungsindex1.55 at 500nm, 1.46 at 1000nm

Größentabelle

1750μl Triangular Quartz Fluorescence Cuvette
ModellBeschreibungPfad
Länge
BandUmriss Dimension
AT-BSM-60291750μl Triangular Quartz Fluorescence Cuvette/1750μl13x13x18.4x45mm
Triangular Quartz Fluorescence Cuvette Side Length 40mm
ModellBeschreibungPfad
Länge
BandUmriss Dimension
AT-BSM-6030Triangular Quartz Fluorescence Cuvette Side Length 40mm//40x40x40x45mm
Hinweis: Wir bieten kundenspezifische Spezifikationen an, um Ihre spezifischen Anforderungen zu erfüllen. Kontaktieren Sie unser Ingenieurteam für eine Beratung.

TOQUARTZ® Solutions for Precision Spectroscopy Challenges with Triangular Quartz Fluorescence Cuvettes

Triangular Quartz Fluorescence Cuvette in Protein Conformation Studies

Protein folding and conformation studies require extreme sensitivity to detect subtle structural changes through intrinsic tryptophan fluorescence or labeled proteins. Traditional rectangular cuvettes often suffer from excessive light scattering and reflection artifacts that mask critical spectral shifts indicating protein unfolding or binding events. Researchers studying protein-ligand interactions, enzyme kinetics, and protein stability need precise fluorescence measurements at extremely low concentrations (nanomolar range) where signal quality becomes paramount.

Die wichtigsten Vorteile

TOQUARTZ®-Lösung

A biotech lab analyzing monoclonal antibody folding reported inconsistent emission shifts using rectangular cuvettes, with 18% signal overlap due to internal reflections. After switching to TOQUARTZ triangular cuvettes, they achieved consistent detection of 1.5 nm spectral shifts at 2 nM protein concentration. This improved their folding transition mapping accuracy by 41%, enabling earlier-stage screening of unstable candidates.

Triangular Quartz Fluorescence Cuvette in Quantum Dot Characterization

Quantum dot researchers and manufacturers require precise optical characterization to determine quantum yield, fluorescence lifetime, and emission profiles of these nanomaterials. The highly reflective nature of quantum dot solutions creates significant measurement challenges, particularly when determining absolute quantum yields where scattered excitation light must be completely eliminated from emission detection. The characterization accuracy directly impacts product quality control and development of next-generation display technologies and biomedical imaging agents.

Die wichtigsten Vorteile

TOQUARTZ®-Lösung

A nanotech firm producing QDs for medical imaging faced 12–15% variability in quantum yield readings due to excitation light bleed-through. Using TOQUARTZ triangular cuvettes, they reduced this to ±1.8%, enabling consistent batch certification. This allowed them to meet ISO 13485 QC standards and reduce rejected lots by 63% over two quarters.

Triangular Quartz Fluorescence Cuvette in Forensic Toxicology

Forensic laboratories analyzing biological samples for trace amounts of drugs, poisons, and metabolites rely on highly sensitive fluorescence techniques to detect compounds at sub-ppb levels. These analyses face unique challenges including limited sample volumes, complex biological matrices causing high background fluorescence, and legal requirements for exceptional measurement reliability. The right-angle measurement capability is essential for separating genuine drug fluorescence from sample matrix interference, particularly in hair, blood, and tissue samples where definitive detection can determine case outcomes.

Die wichtigsten Vorteile

TOQUARTZ®-Lösung

A national forensic lab struggled with 9% false positives in hair drug screening due to matrix interference using standard cuvettes. After adopting TOQUARTZ triangular cuvettes, background fluorescence dropped by 42%, and false positives fell to 1.1%. This improved evidentiary reliability and enabled the lab to pass a federal audit with zero analytical discrepancies.

TOQUARTZ® Customization Options for Triangular Quartz
Fluoreszenz-Küvetten

TOQUARTZ® offers extensive customization options for triangular quartz fluorescence cuvettes to match your specific experimental requirements. Our engineering team works closely with customers to develop custom solutions for specialized applications.

Dimensional Adaptation for Instrument Compatibility

Tailored dimensions ensure seamless integration with proprietary spectroscopy systems.

Structural Geometry Modification

Triangular geometry can be adjusted to meet unique optical path designs.

Anpassungsprozess

We understand the challenges of specifying custom Triangular Quartz Fluorescence Cuvette designs.

Gebrauchs- und Pflegehinweise

Proper handling, cleaning, and storage of triangular quartz fluorescence cuvettes ensures optimal performance and extends product lifespan. Follow these guidelines to maintain your cuvettes in optimal condition.

Handhabung und Messung

Verfahren zur Reinigung

Empfehlungen zur Lagerung

Tipps zur Wartung

Need Engineering Support for
Your Triangular Quartz Fluorescence Cuvette Requirements?

Our technical experts are available to assist with specification selection, custom design, and application support. Contact us today for a consultation.

Warum eine Partnerschaft mit TOQUARTZ

Vorteil der direkten Fabrik

Als direkter Hersteller können wir die zahlreichen Zwischenstufen ausschalten.

Technische Kompetenz

Das technische Team begleitet die Kunden von der Materialauswahl bis zur Designoptimierung und setzt die Spezifikationen in Ergebnisse um.

Flexible Fertigung

Bearbeitung von Standard- und kundenspezifischen Aufträgen mit Hilfe von Kleinserien und Prototyping, um dringende Fristen einzuhalten.

Qualität
Versicherung

3-Stufen-Validierung vor dem Versand:
1. Maßhaltigkeit,
2. Materialreinheit ,
3. Leistungsschwellen

Globale Lieferkette

Zuverlässige globale Logistik zu den industriellen Zentren (Priorität DE/US/JP/KR) mit nachvollziehbaren Meilensteinen.

FAQ

Q: How does the triangular shape benefit fluorescence detection compared to rectangular cuvettes?

A: The triangular geometry minimizes stray light and reduces excitation beam reflection into the detector. This improves signal-to-noise ratio, especially in low-concentration fluorescence assays. It also enables precise 90° excitation-emission configurations. This is critical for accurate quantum yield and anisotropy measurements.

A: Its geometry reduces internal scattering and enhances emission collection efficiency. This makes it ideal for detecting low-abundance analytes such as proteins or metabolites. The four-sided transparency allows flexible detector positioning. Combined with high-purity quartz, it ensures minimal background fluorescence.

A: The unique shape may require custom holders or adapters in some automated readers. However, we offer dimension-matched designs for most commercial systems. The screw cap and flow ports are compatible with robotic pipetting and fluid handling. Contact us for integration support.

A: Yes, the screw cap and optional sealing features allow inert gas purging. This is essential for assays involving oxygen-sensitive fluorophores or enzymatic reactions. The sealed design maintains an anaerobic environment during measurement. It ensures reproducibility in redox-sensitive fluorescence studies.

A: Yes, the cuvette can be customized with inlet and outlet ports for continuous flow applications. This is ideal for kinetic fluorescence assays or real-time monitoring of reactions. The triangular geometry ensures minimal dead volume and consistent flow path. It supports integration with peristaltic or syringe pumps.

Wenden Sie sich für technische Beratung und Preisgestaltung an unser Ingenieurteam. Wir helfen Ihnen bei der Auswahl der optimalen Spezifikationen für Ihre Anwendungsanforderungen.

de_DEDeutsch
Nach oben blättern

Jetzt ein schnelles Angebot anfordern

Sagen Sie uns, was Sie brauchen - Sie erhalten maßgeschneiderte Preise und Vorlaufzeiten innerhalb von 6 Stunden.

* Prüfen Sie die E-Mail nach dem Absenden. Nicht erhalten? Überprüfen Sie die Adresse.