Quartz Micro Cuvette with Black Walls and Black Caps for Laboratory Spectroscopy -TOQUARTZ®
Features of Quartz Micro Cuvette with Black Walls and Black Caps
TOQUARTZ® micro cuvettes are engineered specifically for scientific applications requiring minimal sample volumes and high optical performance. Our black wall design provides significant advantages for fluorescence and sensitive spectroscopic measurements.
Micro Volume Capability
Designed for precious samples with minimal volume requirements, available in 50μl, 100μl, 200μl, and 300μl capacities.
مقاومة المواد الكيميائية
Excellent resistance to acids, bases, and organic solvents, making these cuvettes suitable for a wide range of chemical analyses.
الأداء البصري
High-purity quartz (≥99.98% SiO₂, max. up to 99.995%) with excellent transmission range from 200nm to 2500nm, ideal for UV-Vis and fluorescence applications.

- Optimized black walls for Fluorescence
- ثبات حراري: حتى 100 درجة مئوية
- التخصيص متاح
Technical Specifications & Dimensions of Quartz Micro Cuvette with Black Walls and Black Caps
المواصفات الفنية
الخصائص الفيزيائية
المعلمة | المواصفات |
المواد | كوارتز عالي النقاء (≥99.98% SiO2) |
تشطيب السطح | Optical polishing on window surfaces |
المعالجة الجدارية | طلاء أسود لعزل الضوء |
الخواص الكيميائية
المعلمة | المواصفات |
مقاومة المواد الكيميائية | Excellent to most acids, bases, and solvents |
نطاق استقرار الأس الهيدروجيني | 1-14 |
توافق المذيبات | متوافق مع معظم المذيبات العضوية |
الكارهة للماء | معتدل (زاوية التلامس ~ 30 درجة) |
الخصائص البصرية
المعلمة | المواصفات |
نطاق الإرسال | 200-2500 نانومتر |
Absorbance Accuracy | ±0.005A |
Window Flatness | ≤λ/4 |
تقليل الضوء الشارد | >99% (black walls) |
جدول المقاسات

الطراز | الوصف | الطول الموجي | المسار الطول | الحجم | الاستقرار الحراري | بُعد المخطط التفصيلي |
AT-BSM-4028 | 50μl Quartz Micro Cuvette with Black Walls and Black Cap | 200 نانومتر - 2500 نانومتر | 10 مم | 50 ميكرولتر | 100℃ | 12.5 × 12.5 × 12.5 × 45 مم |

الطراز | الوصف | الطول الموجي | المسار الطول | الحجم | الاستقرار الحراري | بُعد المخطط التفصيلي |
AT-BSM-4022 | 50μl Quartz Micro Cuvette with Black Walls and Black Lid | 200 نانومتر - 2500 نانومتر | 10 مم | 50 ميكرولتر | 100℃ | 12.5 × 12.5 × 12.5 × 45 مم |

الطراز | الوصف | الطول الموجي | المسار الطول | الحجم | الاستقرار الحراري | بُعد المخطط التفصيلي |
AT-BSM-4023 | 100μl Quartz Micro Cuvette with Black Walls and Black Cap | 200 نانومتر - 2500 نانومتر | 10 مم | 100 ميكرولتر | 100℃ | 12.5 × 12.5 × 12.5 × 45 مم |

الطراز | الوصف | الطول الموجي | المسار الطول | الحجم | الاستقرار الحراري | بُعد المخطط التفصيلي |
AT-BSM-4025 | 200 μlQuartz Micro Cuvette with Black Walls and Black Cap | 200 نانومتر - 2500 نانومتر | 10 مم | 200 ميكرولتر | 100℃ | 12.5 × 12.5 × 12.5 × 45 مم |

الطراز | الوصف | الطول الموجي | المسار الطول | الحجم | الاستقرار الحراري | بُعد المخطط التفصيلي |
AT-BSM-4024 | 300 μlQuartz Micro Cuvette with Black Walls and Black Cap | 200 نانومتر - 2500 نانومتر | 10 مم | 300 ميكرولتر | 100℃ | 12.5 × 12.5 × 12.5 × 45 مم |
TOQUARTZ® Solving Laboratory Challenges with Black Wall Quartz Micro Cuvettes
Quartz Micro Cuvette with Black Walls for DNA/RNA Quantification
المزايا الرئيسية
-
Minimized Sample Volume Loss
Only 50μl sample required vs. 1–3ml in standard cuvettes, reducing nucleic acid waste by over 95%. -
Stray Light Suppression Efficiency
Black walls reduce background interference by 87%, improving fluorescence signal-to-noise ratio. -
دقة المسار البصري المتناسقة
10.00mm ±0.05mm path length ensures <2% deviation in nucleic acid concentration readings.
محلول توكارتز
A molecular biology lab in Heidelberg, Germany, reported inconsistent DNA quantification using standard 1ml cuvettes due to sample scarcity and high background noise. After switching to TOQUARTZ® 50μl black wall micro cuvettes, they achieved a 92% reduction in sample usage and a 1.8× improvement in fluorescence signal clarity. This enabled accurate quantification of DNA at concentrations as low as 0.3ng/μl, critical for their low-yield extraction workflows.
Quartz Micro Cuvette with Black Walls for Trace Analysis in Environmental Samples
المزايا الرئيسية
-
Enhanced Detection at ppb Levels
Black wall design improves fluorescence detection sensitivity by 1.6× for analytes below 10ppb. -
Reduced Optical Interference
Stray light suppression exceeds 90%, critical for detecting PAHs and heavy metals in complex matrices. -
Low Volume Compatibility
Supports 50–300μl sample volumes, ideal for limited-volume soil and water extracts.
محلول توكارتز
An environmental testing lab in Ontario, Canada, faced challenges detecting trace polycyclic aromatic hydrocarbons (PAHs) in river water due to high background fluorescence. Using TOQUARTZ® 100μl black wall cuvettes, they reduced optical noise by 21% and achieved consistent detection of benzo pyrene at 4.7ppb. This allowed them to meet regulatory reporting thresholds without increasing sample volume or processing time.
Quartz Micro Cuvette with Black Walls for Pharmaceutical Formulation Analysis
المزايا الرئيسية
-
API Conservation in Early R&D
Requires only 100μl per test, reducing API consumption by up to 80% during formulation screening. -
Excipient Interference Mitigation
Black walls block lateral light scatter, improving accuracy in complex excipient matrices. -
Precision Path Length Control
±0.05mm tolerance ensures <1.5% deviation in absorbance-based API concentration assays.
محلول توكارتز
A pharmaceutical R&D center in Osaka, Japan, struggled with accurate UV absorbance readings of early-stage API formulations due to excipient interference and limited sample availability. After adopting TOQUARTZ® 100μl black wall cuvettes, they reduced API usage per test from 500μl to 100μl and improved measurement repeatability by 93%. This enabled faster iteration of formulation batches while maintaining QC compliance.
TOQUARTZ® Customization Options for Quartz Micro Cuvette with Black Walls and Black Caps
الأبعاد المخصصة
- أطوال المسارات غير القياسية
- Specialized volumes
- Custom height or width dimensions
- تصميم هندسي خاص للغرفة
ميزات خاصة
- Screw-cap or snap-lock lid options
- Magnetic stirring compatibility
- Flow-through ports for continuous monitoring
- تعديلات التحكم في درجة الحرارة
معالجات السطح
- تكوينات الجدار الأسود الجزئي
- طلاءات مضادة للانعكاس
- المعالجات السطحية الكارهة للماء
- Specialized optical window polishing
Usage Guide of Quartz Micro Cuvette with Black Walls and Black Caps
Proper Handling Procedures
- Always handle cuvettes by the top or opaque surfaces to avoid fingerprints on optical windows.
- Fill cuvettes using micropipettes, taking care not to scratch the interior surfaces.
- For most accurate results, ensure sample fills to the recommended volume mark without air bubbles.
- Always use the provided caps to prevent sample evaporation during measurement.
Cleaning Instructions
- اشطفها مباشرةً بعد الاستخدام بمذيب مناسب متوافق مع العينة.
- For thorough cleaning, use 2% Hellmanex III solution, followed by thorough rinsing with ultrapure water.
- For stubborn residues, soak in 5% HCl solution for 30 minutes (avoid using HF, which can etch quartz).
- Dry with clean, compressed air or nitrogen gas. Never use paper towels on optical surfaces.
أفضل ممارسات القياس
- Always use the same orientation in the instrument for consistency between measurements.
- For fluorescence measurements, ensure the excitation beam passes through the clear windows, not the black walls.
- Allow temperature-sensitive samples to equilibrate to room temperature before measurement.
- Regularly check for scratches or damage that could affect optical performance.
توصيات التخزين
- Store clean, dry cuvettes in their original protective case or in a dust-free container.
- Keep cuvettes away from abrasive surfaces that could scratch the optical windows.
- Avoid prolonged exposure to strong UV light when not in use.
Need Technical Assistance with Quartz Micro Cuvettes?
لماذا الشراكة مع TOQUARTZ
ميزة المصنع المباشر
وبصفتنا شركة تصنيع مباشرة، يمكننا الاستغناء عن الروابط الوسيطة العديدة.
الخبرة الهندسية
يقوم الفريق التقني بتوجيه العملاء بدءاً من اختيار المواد إلى تحسين التصميم، وترجمة المواصفات إلى مخرجات.
التصنيع المرن
التعامل مع الطلبيات القياسية والمخصصة من خلال الخبرة في مجال الدُفعات الصغيرة والصرامة في وضع النماذج الأولية للوفاء بالمواعيد النهائية العاجلة.
الجودة
التأمين
التحقق من الصحة قبل الشحن في 3 خطوات:
1. دقة الأبعاد,
2. نقاء المادة,
3 - عتبات الأداء
سلسلة التوريد العالمية
خدمات لوجستية عالمية موثوقة إلى المراكز الصناعية (أولوية DE/US/JP/KR) مع مراحل إنجاز يمكن تتبعها.
المنتجات المستعادة
تقدم TOQUARTZ، بصفتها شركة تصنيع متخصصة تتمتع بقدرات المصنع المباشرة، حلول الكوارتز القياسية والمخصصة مع الدعم الهندسي طوال عملية تحديد المواصفات والتنفيذ.
الأسئلة الشائعة
Q: Will the black walls of the Quartz Micro Cuvette with Black Walls and Black Caps affect UV-Vis transmission?
A: No, the optical windows remain transparent quartz; only the side walls are black-coated, ensuring full UV-Vis transmission (200–2500nm) through the measurement path.
Q: Can the black coating on the Quartz Micro Cuvette with Black Walls and Black Caps degrade over time or with cleaning?
A: The black coating is chemically bonded and resistant to most solvents, but abrasive cleaning or exposure to HF can damage it. Use non-abrasive cleaning methods only.
Q: How does the black cap of the Quartz Micro Cuvette with Black Walls and Black Caps help in fluorescence analysis?
A: The black cap prevents ambient light from entering the cuvette from the top, reducing background noise and improving signal-to-noise ratio in fluorescence detection.
Q: Are the Quartz Micro Cuvette with Black Walls and Black Caps compatible with standard spectrophotometers and fluorometers?
A: Yes, they follow the standard 12.5mm × 12.5mm × 45mm external dimensions and fit most commercial instruments with 10mm path length holders.
Q: Why do some fluorescence readings vary when using the Quartz Micro Cuvette with Black Walls and Black Caps?
A: Variations may result from improper orientation, cap misalignment, or inconsistent sample volume. Always align the optical windows correctly and fill to the recommended volume.
اتصل بفريقنا الهندسي للحصول على الاستشارات الفنية والتسعير. سنساعدك في اختيار المواصفات المثلى لمتطلبات تطبيقك.