1. Ev
  2. /
  3. Türleri
  4. /
  5. Kuvars Küvet
  6. /
  7. Kuvars Mikro Küvet
  8. /
  9. Bubble-Minimizing Quartz Micro Fluorescence...

Bubble-Minimizing Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge -TOQUARTZ®

TOQUARTZ® High-purity quartz micro fluorescence cuvette featuring an open-top design with precision slanted edge for easy sample loading. Manufactured from optical-grade quartz (≥99.98% SiO₂). Ideal for DNA/RNA quantification, protein analysis, and ultra-low volume fluorescence spectroscopy applications.
Adedi Yok
Özel Tasarım
Doğrudan Fabrika
Teknik Destek

Features of Quartz Micro Fluorescence Cuvette with
Open Top and Slanted Edge

TOQUARTZ® high-purity quartz micro fluorescence cuvettes are designed to deliver exceptional performance for precision spectroscopy applications. Each cuvette is manufactured to exacting standards to ensure consistent results across your research and testing protocols.

Precision Slanted Edge Design

ngineered for easy sample loading and reduced bubble formation, minimizing experimental errors during critical research.

Optik Performans

Transmission range of 200-2500nm with no absorption peaks, making it ideal for UV-VIS-NIR spectroscopy applications.

Kimyasal Direnç

Maintains stability against acids, bases, and corrosive solutions, ensuring longevity even in harsh chemical environments.

Termal Kararlılık

Withstands temperatures up to 100°C, suitable for various thermal applications and experimental conditions.

Low Volume Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge
TOQUARTZ® Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge

Technical Specifications & Dimensions of Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge

TOQUARTZ® quartz micro fluorescence cuvette is manufactured to precise specifications to ensure compatibility with standard laboratory equipment and consistent experimental results.

Teknik Özellikler

ParametreŞartname
MalzemeHigh-purity quartz (≥99.98% SiO2, max. up to 99.995%)
Çekme Dayanımı50 MPa
Yoğunluk2,2 g/cm³
Termal Genleşme Katsayısı5.5×10-7/℃
Yüzey İşlemiOptical polish on all four sides
Asit DirenciMükemmel (HF hariç)
Alkali DirencipH 12'ye kadar iyi
Solvent UyumluluğuÇoğu organik çözücü ile uyumludur
Biyouyumlulukİnerttir, biyolojik örneklerle reaktif değildir
İletim Aralığı200-2500nm
UV Kesimi<190nm
Kırılma İndisi589.3nm'de 1.46

Beden Tablosu

140μl Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge
ModelAçıklamaDalga boyuYol
Uzunluk
CiltTermal KararlılıkAnahat Boyutları
AT-BSM-4020140μl Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge200nm-2500nm1mm/4mm140μl100℃12,5×12,5x45mm
Not: Özel gereksinimlerinizi karşılamak için özel spesifikasyonlar sunuyoruz. Danışma için mühendislik ekibimizle iletişime geçin.

TOQUARTZ® Solving Laboratory Challenges with Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge

Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge in Single-Cell Fluorescence Imaging Chambers

In single-cell fluorescence imaging, researchers often isolate and analyze individual cells in microfluidic or static chambers. These experiments require cuvettes with unobstructed optical access from all four sides to allow multi-angle excitation and emission detection. Traditional cuvettes with caps or limited optical windows obstruct light paths and reduce signal fidelity. Additionally, the need to gently load fragile single-cell suspensions without disturbing the sample makes conventional vertical loading impractical.

Temel Avantajlar

TOQUARTZ® çözümü

A German university lab conducting single-cell calcium imaging reported 22% signal loss due to sidewall refraction in standard 2-window cuvettes. After switching to TOQUARTZ®’s 4-sided transparent, open-top slanted cuvettes, signal-to-noise ratio improved by 31%, and cell viability during loading increased from 87% to 96%, enabling more accurate kinetic tracking of intracellular events.

Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge in Automated Liquid Handling Systems for High-Throughput Screening

In pharmaceutical and biotech labs, automated pipetting robots are used for high-throughput fluorescence assays. These systems require cuvettes that can be accessed from the top without obstruction and allow precise, bubble-free sample dispensing. Standard capped or narrow-neck cuvettes often cause pipette tip collisions or bubble entrapment, leading to failed assays and wasted reagents.

Temel Avantajlar

TOQUARTZ® çözümü

A US-based biotech CRO using Tecan EVO robots faced a 14% pipetting failure rate due to tip collisions with capped cuvettes. After adopting TOQUARTZ® open-top slanted cuvettes, failure rates dropped to 1.8%, and assay throughput increased by 19%, saving over $3,800/month in reagent waste and reruns.

Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge in Photobleaching Kinetics and Time-Resolved Fluorescence Decay Studies

Time-resolved fluorescence and photobleaching studies require precise control of excitation light exposure and rapid sample replacement. Researchers often need to quickly inject or replace samples between runs without disturbing the optical alignment. Cuvettes with caps or narrow openings slow down this process and introduce alignment errors. Additionally, any internal reflection from non-polished surfaces can distort decay curves.

Temel Avantajlar

TOQUARTZ® çözümü

A photophysics lab in Kyoto University reported 17% curve distortion due to internal reflections in standard 2-polish cuvettes. Switching to TOQUARTZ® 4-polish, open-top slanted cuvettes reduced distortion to under 3%, and sample exchange time dropped from 12s to 6.8s, enabling higher temporal resolution in photobleaching kinetics.

TOQUARTZ® Customization Options for Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge

TOQUARTZ® offers specialized customization services to meet your exact experimental requirements and instrument specifications.

Custom Dimensional Modifications

Material and Surface Options

Özelleştirme Süreci

Usage Guide of Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge

Proper handling and maintenance of your quartz micro fluorescence cuvette will ensure optimal performance and extend its service life. Follow these guidelines for best results in your laboratory applications.

Sample Loading Procedure

Önemli Önlemler

Temizlik ve Bakım

Need Technical Consultation for Your Quartz Micro Fluorescence Cuvette Requirements?

Our engineers provide free project consultation to help you select the right specifications for your application.
With experience serving research institutions worldwide, we can recommend the optimal solution for your specific needs.

Neden TOQUARTZ ile Ortak Olmalısınız?

Doğrudan Fabrika Avantajı

Doğrudan bir üretici olarak, çok sayıda ara bağlantıyı ortadan kaldırabiliriz.

Mühendislik Uzmanlığı

Teknik ekip, malzeme seçiminden tasarım optimizasyonuna kadar müşterilere rehberlik eder ve teknik özellikleri çıktılara dönüştürür.

Esnek Üretim

Acil teslim tarihlerini karşılamak için küçük parti uzmanlığı ve prototipleme titizliği ile standart ve özel siparişleri ele alma.

Kalite
Güvence

Sevkiyat öncesi 3 aşamalı doğrulama:
1. boyutsal doğruluk,
2. malzeme saflığı,
3. performans eşi̇kleri̇

Küresel Tedarik Zinciri

Endüstriyel merkezlere (DE/US/JP/KR öncelikli) izlenebilir kilometre taşlarıyla güvenilir küresel lojistik.

SSS

Q: What are the advantages of four-sided optical transparency in the Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge?

A: The four-sided optical transparency allows multi-angle excitation and emission detection, which is essential for single-cell imaging, confocal microscopy, and time-resolved fluorescence studies requiring full-spectrum access.

A: For short to mid-duration assays, evaporation is minimal due to the small surface area. For longer runs, we recommend using a compatible sealing film or placing the cuvette in a humidity-controlled chamber.

A: The slanted edge guides the pipette tip naturally into the chamber, reducing the risk of tip misalignment and minimizing bubble formation during sample loading, especially in automated systems.

A: While open-top designs are more exposed, proper lab protocols (e.g., using filtered pipette tips and clean benches) effectively mitigate contamination risks. The benefit is faster access and easier cleaning.

A: Yes, the open-top design allows sub-5-second sample replacement, making it ideal for kinetic fluorescence assays and photobleaching studies where timing is critical.

Teknik danışmanlık ve fiyatlandırma için mühendislik ekibimizle iletişime geçin. Uygulama gereksinimleriniz için en uygun özellikleri seçmenize yardımcı olacağız.

tr_TRTürkçe
Üste Kaydır

Şimdi Hızlı Teklif Alın

Bize neye ihtiyacınız olduğunu söyleyin - 6 saat içinde size özel fiyatlandırma ve teslim süresi alın.

* Gönderdikten sonra e-postayı kontrol edin. Alınmadı mı? Adresi doğrulayın.