Precision Black Quartz Cuvette UV JGS1 Micro Sample Cell for UV-Vis Spectroscopy -TOQUARTZ®

Premium black UV quartz cuvettes manufactured with 99.98%+ SiO₂ purity for superior optical performance in UV-VIS spectroscopy.

Specially designed with black walls to minimize stray light interference, enhancing measurement accuracy for fluorescence detection, trace analysis, and DNA/RNA quantification applications.
Adedi Yok
Özel Tasarım
Doğrudan Fabrika
Teknik Destek

Features of Black Quartz Cuvette Cell

TOQUARTZ® black UV quartz cuvettes feature specialized construction with black walls and transparent windows to minimize stray light interference in sensitive optical measurements. The high-purity quartz material offers exceptional performance across the UV-visible spectrum.

Optik Performans

Malzeme Özellikleri

Black UV quartz cuvette with precision optical path for fluorescence detection
TOQUARTZ® Fused Black Quartz Cuvette

Technical Specifications & Dimensions of Black Quartz Cuvette

TOQUARTZ® black UV quartz cuvettes are available in various configurations to meet your specific spectroscopy requirements. Standard specifications are listed below, with custom options available upon request.

Technical Specifications of Black Quartz Glass Cuvette

ParametreStandart ŞartnameÖzel Seçenekler
MalzemeHigh-purity quartz (99.98%+ SiO₂)
Yol Uzunluğu10mm1mm, 2mm, 5mm, 20mm, 30mm, 50mm, 100mm
Outer Dimensions12.5 × 12.5 × 45mmCustom per requirement
Yüzey İşlemiPencerelerde optik parlatmaCustom polishing levels
Termal Direnç1100°C'ye kadar
Kimyasal DirençÇoğu asit, baz ve solvente karşı dayanıklıdır
Kapak SeçenekleriPTFE stoppers, screw capsCustom lid designs

Size of of Black Quartz Cuvette UV JGS1 Micro Sample Cell

Customizable Micro Black Quartz Cuvette
ModelAçıklamaDalga boyuYol
Uzunluk
CiltTemperatureAnahat Boyutları
AT-BSM-053Customizable Micro Black Quartz Cuvette200nm-2500nm10mm100μl100℃12,5×12,5x8mm
100μl Black Quartz Cuvette for Protein Determination
ModelAçıklamaDalga boyuYol
Uzunluk
CiltTemperatureAnahat Boyutları
AT-BSM-047100μl Black Quartz Cuvette for Protein Determination200nm-2500nm10mm100μl100℃12,5×12,5x25mm
350μl Black Quartz Cuvette JGS1 Micro Sample Cell with Lid
ModelAçıklamaDalga boyuYol
Uzunluk
CiltTemperatureAnahat Boyutları
AT-BSM-013350μl Black Quartz Cuvette JGS1 Micro Sample Cell with Lid200nm-2500nm10mm350μl100℃12,5×12,5x45mm
1ml Black Quartz Cuvette JGS1 Micro Sample Cell with Lid
ModelAçıklamaDalga boyuYol
Uzunluk
CiltTemperatureAnahat Boyutları
AT-BSM-0051.05ml Black Quartz Cuvette JGS1 Micro Sample Cell with Lid200nm-2500nm10mm1.05ml100℃12,5×12,5x45mm
1.4ml Black Quartz Cuvette JGS1 Micro Sample Cell with Lid
ModelAçıklamaDalga boyuYol
Uzunluk
CiltTemperatureAnahat Boyutları
AT-BSM-0491.4ml Black Quartz Cuvette JGS1 Micro Sample Cell with Lid200nm-2500nm10mm1.4ml100℃12,5×12,5x45mm
1.75ml Black Quartz Cuvette JGS1 Micro Sample Cell with Lid
ModelAçıklamaDalga boyuYol
Uzunluk
CiltTemperatureAnahat Boyutları
AT-BSM-0501.75ml Black Quartz Cuvette JGS1 Micro Sample Cell with Lid200nm-2500nm10mm1.75ml100℃12,5×12,5x45mm
Not: Özel gereksinimlerinizi karşılamak için özel spesifikasyonlar sunuyoruz. Danışma için mühendislik ekibimizle iletişime geçin.

TOQUARTZ® Solving Critical Challenges with Black UV Quartz Cuvettes

Black Quartz Glass Cuvette Cells for Fluorescence Detection

Fluorescence spectroscopy requires exceptionally low background signal and minimal stray light interference for accurate detection of weak emission signals. Standard transparent cuvettes often result in light scattering that reduces measurement sensitivity, particularly when detecting low-concentration samples or molecules with weak quantum yields.

Temel Avantajlar

TOQUARTZ® çözümü

A biotech lab in Germany reported inconsistent fluorescence readings at 10⁻⁹ M due to cuvette wall reflection.

TOQUARTZ® black UV quartz cuvettes, with 98.7% stray light suppression, stabilized their signal baseline within ±0.3%, enabling reliable detection of low-emission fluorophores. This improvement was directly attributed to our optical wall coating precision, not just material purity.

Black Quartz Cuvette for Precision DNA/RNA Quantification

DNA and RNA quantification using UV absorbance at 260nm demands high precision and reproducibility. Conventional cuvettes often introduce variability through internal reflections and stray light, leading to inconsistent readings particularly at low concentrations where accuracy is most critical for applications like qPCR, sequencing, and gene expression studies.

Temel Avantajlar

TOQUARTZ® çözümü

A genomics lab in the US faced inconsistent 260/280 ratios due to cuvette dimensional variance.
TOQUARTZ® black UV quartz cuvettes, with ±0.1mm path length control, reduced their inter-sample ratio deviation from 3.2% to 1.1%. This dimensional precision—not just stray light control—was key to improving nucleic acid purity assessments.

Black UV Quartz Cuvette for Instrument Manufacturing Integration

Analytical instrument manufacturers require precision-machined components with consistent optical properties for integration into their spectrophotometers and automated analyzers. Traditional cuvettes with dimensional variations often cause instrument calibration issues, alignment problems, and inconsistent results, directly impacting instrument performance and reliability.

Temel Avantajlar

TOQUARTZ® çözümü

A Japanese instrument OEM experienced 7% alignment failure in auto-sampler due to cuvette dimensional drift.
TOQUARTZ® black UV quartz cuvettes, with 0.02° window parallelism and ±0.1mm tolerance, enabled full mechanical compatibility, reducing calibration downtime by 80%. The solution stemmed from our precision machining, not just delivery speed.

Customization Services for TOQUARTZ® Black Quartz Cuvette

TOQUARTZ® offers comprehensive customization services for black UV quartz cuvettes to meet your specific analytical requirements. Our engineering team works directly with you to design and manufacture cuvettes tailored to your unique applications.

Boyutsal Özelleştirme

• Custom path lengths (1-100mm)
• Custom inner volumes
• Special outer dimensions



Ideal for instrument manufacturers requiring precise fit with existing equipment.

Design
Özelleştirme

• Flow-through designs
• Custom lid/cap configurations
• Specialized window arrangements
• Multiple optical path options


Perfect for specialized applications requiring unique sample handling capabilities.

Surface
Treatments

• Enhanced optical polishing
• Anti-reflection coatings
• Black wall optimization
• Custom markings/graduations
• Multiple optical path options

Supports applications requiring maximum optical performance and stray light reduction.

TOQUARTZ® Özelleştirme Süreci

Gereksinim Tartışması

TOQUARTZ® engineers consult with you to understand your application requirements, technical specifications, and performance objectives.

Tasarım ve Teklif

We develop a custom design proposal with detailed specifications, timeline, and pricing for your review and approval.

Prototip Geliştirme

For new designs, we produce a small batch of prototype cuvettes for testing and validation in your application.

Üretim ve Kalite Kontrol

After approval, we proceed with full production including comprehensive QC testing before delivery. Our standard lead time for custom black UV quartz cuvettes is 2-3 weeks.

Usage Guide of Black Fused Quartz Cuvette

Proper handling and maintenance of black UV quartz cuvettes is essential to maintain optical performance and extend product lifespan. Follow these guidelines to achieve optimal results in your spectroscopic applications.

Kullanım ve Hazırlık

Temizlik ve Bakım

Correct Alignment of Black UV Quartz Cuvettes in Spectroscopic Instruments

Proper alignment of the cuvette’s optical windows with the instrument’s light path is essential to ensure accurate absorbance or fluorescence measurements and minimize signal distortion.

Need a Engineering Support for Custom Black UV Quartz Cuvette Solution?

Our technical team can provide drawing assistance and material recommendations for your specific application.
We accept custom designs via sketches, CAD files, or even photographs of existing parts.

Neden TOQUARTZ ile Ortak Olmalısınız?

Doğrudan Fabrika Avantajı

Doğrudan bir üretici olarak, çok sayıda ara bağlantıyı ortadan kaldırabiliriz.

Mühendislik Uzmanlığı

Teknik ekip, malzeme seçiminden tasarım optimizasyonuna kadar müşterilere rehberlik eder ve teknik özellikleri çıktılara dönüştürür.

Esnek Üretim

Acil teslim tarihlerini karşılamak için küçük parti uzmanlığı ve prototipleme titizliği ile standart ve özel siparişleri ele alma.

Kalite
Güvence

Sevkiyat öncesi 3 aşamalı doğrulama:
1. boyutsal doğruluk,
2. malzeme saflığı,
3. performans eşi̇kleri̇

Küresel Tedarik Zinciri

Endüstriyel merkezlere (DE/US/JP/KR öncelikli) izlenebilir kilometre taşlarıyla güvenilir küresel lojistik.

SSS

Q: What is a black UV quartz cuvette?

A: A black UV quartz cuvette is a specialized optical cell made from high-purity quartz with black-colored walls and transparent windows. The black walls absorb stray light to minimize interference and background signal, while the transparent windows allow the analytical light beam to pass through the sample for spectroscopic measurements.

A: Black UV quartz cuvettes significantly reduce stray light and internal reflections, providing superior performance for applications requiring high sensitivity and accuracy, such as fluorescence spectroscopy and low-concentration DNA/RNA quantification. They deliver improved signal-to-noise ratio and more consistent results for trace analysis applications.

A: TOQUARTZ® black UV quartz cuvettes transmit light from 120nm in the deep UV through 4500nm in the infrared region. The optical windows have excellent transmission characteristics with no absorption peaks throughout this range, making them suitable for both UV and visible spectroscopy applications.

A: Clean black UV quartz cuvettes by first rinsing with the same solvent used for your samples, followed by spectroscopic-grade acetone or methanol. For thorough cleaning, soak in 5% HCl solution, then rinse extensively with deionized water. Dry with compressed air or nitrogen, never with paper tissues which can scratch the optical surfaces.

A: Standard black UV quartz cuvettes are available in 10mm path length, which is the industry standard. However, we offer custom path lengths ranging from 1mm for high-concentration samples to 100mm for extremely dilute solutions. Common alternatives include 2mm, 5mm, 20mm, and 50mm path lengths.

A: Black UV quartz cuvettes are resistant to most chemicals including acids, bases, organic solvents, and salt solutions. They should not be used with hydrofluoric acid (HF) or hot concentrated phosphoric acid, which can etch quartz surfaces. The high chemical resistance makes them suitable for a wide range of analytical applications.