Features of Air Free Quartz Cuvette
TOQUARTZ® air free quartz cuvettes are engineered for applications requiring sealed environments during spectroscopic analysis. These specialized cuvettes provide the optimal combination of optical performance, chemical resistance, and reliable sealing capabilities.
Reliable Sealing Mechanism
Vacuum quartz cuvette designs featuring precision-engineered PTFE stoppers or ground glass joints that provide gas-tight sealing. Each unit undergoes rigorous testing to ensure reliable containment of inert atmospheres.
Оптическая передача
Exceptional quartz cuvette wavelength range from 200nm to 2500nm with no absorption peaks, ideal for UV, visible, and IR spectroscopy applications. Consistent light path length ensures accurate and reproducible measurements.
Химическая стойкость
Excellent quartz cuvette solvent compatibility with stability against acids, bases, and most chemical reagents. Resistant to high temperatures up to 1100°C, making them suitable for various reaction conditions.

- Gas-Tight Sealing
- UV-IR Compatible
- High Purity Quartz
Technical Specifications & Dimensions of Vacuum Quartz Glass Cuvette
Technical Specifications of Vacuum Quartz Cuvette
Параметр | Технические характеристики |
Материал | Высокочистый кварц (>99,98% SiO₂) |
Диапазон оптической передачи | 200nm – 2500nm, no absorption peaks |
Стандартная длина пути | 1 мм, 2 мм, 5 мм, 10 мм, 20 мм, 50 мм, 100 мм |
Допуск на размеры | ±0.1mm (standard), ±0.2mm (specialized designs) |
Sealing Mechanism | PTFE stoppers, ground glass joints, or custom fittings |
Sealing Performance | Passes water seal test and pressure testing |
Температурная стойкость | Up to 1100°C (quartz body) |
Коэффициент теплового расширения | 5.5 × 10-⁷/K |
Химическая стойкость | Resistant to acids, bases, organic solvents (except HF) |
Обработка поверхности | Polished, bubble-free, scratch-free optical windows |
Quartz Cuvette Absorbance Range | 0.01 – 3.0 AU (depending on path length) |
Size of of Vacuum Quartz Cuvette

Артикул отсутствует. | Описание | Вместимость | Длина пути | LxWxH | Диапазон длин волн |
AT-BSM-5001 | 3.5ml Quartz cuvette(10mm) | 3,5 мл | 10 мм | 12,5×12,5x45 мм | 200 нм-2500 нм |

Артикул отсутствует. | Описание | Вместимость | Длина пути | LxWxH | Диапазон длин волн |
AT-BSM-5002 | Quartz cuvette cell with screw cap for lab | 3,5 мл | 10 мм | 12.5×12.5x60mm | 200 нм-2500 нм |

Артикул отсутствует. | Описание | Вместимость | Длина пути | LxWxH | Диапазон длин волн |
AT-BSM-5003 | Quartz cuvette cell with screw cap | 3,5 мл | 10 мм | 12,5×12,5x45 мм | 200 нм-2500 нм |

Артикул отсутствует. | Описание | Вместимость | Длина пути | LxWxH | Диапазон длин волн |
AT-BSM-5004 | Standard quartz cuvette cell with stopper without glue | 3,5 мл | 10 мм (4 polished sides) | 12,5×12,5x45 мм | 200 нм-2500 нм |

Артикул отсутствует. | Описание | Вместимость | Длина пути | LxWxH | Диапазон длин волн |
AT-BSM-5005 | Quartz closed cuvette airtight paired UV quartz band plug | 3,5 мл | 10 мм (4 polished sides) | 12,5×12,5x45 мм | 200 нм-2500 нм |
TOQUARTZ® Solving Challenges with Vacuum Fused Quartz Cuvettes
Air Free Quartz Glass Cuvettes for Oxygen-Sensitive Spectroscopy
Ключевые преимущества
- TOQUARTZ® Vacuum-sealed quartz cuvettes prevent oxygen ingress for over 72 hours under 1 atm pressure.
- Maintains spectral stability for oxygen-sensitive dyes in UV-Vis range (200–400nm).
- PTFE Stopper Leakage Rate < 1×10⁻⁶ mbar·L/s
- Internal O₂ concentration remains < 0.5 ppm after 48h sealed storage.
раствор TOQUARTZ®
A German analytical instrument manufacturer reported 12% sample degradation during oxygen-sensitive UV-Vis analysis.
TOQUARTZ air free cuvettes reduced degradation to less than 0.5%, enabling accurate analysis of photosensitive compounds over extended periods.
Vacuum Fused Quartz Cuvettes for Inert Gas Reactions
Ключевые преимущества
- Enables real-time reaction monitoring under N₂ or Ar with inlet/outlet flow control.
- Reaction Chamber Volume Precision ±0.05mL
- Allows temperature probe insertion without compromising gas-tight integrity.
- Pressure Stability up to 1.5 bar
- Gas Purge Efficiency > 99.9% in 3 min
раствор TOQUARTZ®
A pharmaceutical R&D team required real-time UV-Vis monitoring of a nitrogen-sensitive intermediate.
TOQUARTZ® vacuum quartz cuvettes with dual gas ports enabled continuous N₂ flow and stable absorbance readings over 6 hours.
Compared to open cuvettes, signal drift was reduced by 87%, and reaction reproducibility improved by 42%.
This allowed the team to validate a new synthesis route without redesigning their spectrometer setup.
Air Free Fused Quartz Cuvettes for Microvolume Analysis
Ключевые преимущества
- Evaporation Rate < 0.3% over 1 hour
- Optical Path Length Tolerance ±0.02mm
- Sample Recovery Rate > 98%
- Prevents fogging during temperature shifts, preserving optical clarity in low-volume assays.
- 5mm diameter neck allows direct sample injection without contamination risk.
раствор TOQUARTZ®
A biomedical lab analyzing 100μL enzyme samples faced 10–15% volume loss due to evaporation in open cuvettes.
Using TOQUARTZ® vacuum quartz cuvettes with precision-sealed caps, evaporation dropped below 0.3% over 60 minutes.
This improved assay repeatability by 35% and reduced reagent waste by 40%, enabling more cost-effective screening.
The lab integrated the cuvettes into their standard protocol for all microvolume UV-Vis assays.
Customization Services for TOQUARTZ® Fused Quartz Air Free Cuvettes
Варианты индивидуального дизайна
Пользовательская длина пути
Non-standard quartz cuvette path length options to optimize for specific sample concentrations and measurement requirements.
Specialized Sealing Mechanisms
Custom stoppers, valves, sample ports, or connection interfaces designed for compatibility with your existing equipment.
Модификации, связанные с потоком
Integration of inlet/outlet ports for continuous flow applications while maintaining airtight conditions.
Temperature Control Features
Modifications for integration with temperature control systems for reaction monitoring under controlled conditions.
Multi-Cell Configurations
Custom designs with multiple sealed compartments for simultaneous sample analysis or reference measurements.
Процесс разработки TOQUARTZ® на заказ
Техническая консультация
TOQUARTZ® engineers work with you to understand application requirements, specifications, and integration needs.
Предложение по дизайну
We provide technical drawings based on your requirements, with recommendations for optimization if needed.
Разработка прототипа
Rapid prototyping with sample delivery within 7-14 days for testing and validation.
Refinement & Production
Based on feedback, we refine the design and proceed with production of your custom order.
Контроль качества и тестирование
Rigorous testing for optical performance, sealing efficiency, and dimensional accuracy before shipping.
Vacuum Fused Quartz Cuvette Cleaning Procedure
Standard Cleaning Protocol
- 1. Initial Rinse: Rinse with distilled water immediately after use to remove water-soluble substances.
- 2. Solvent Selection: For organic contaminants, use ethanol-water mixture (1:1). For inorganic residues, use dilute HCl (1:2).
- 3. Cleaning Method: Gently fill and empty the cuvette with cleaning solution 3-5 times. Never use abrasive materials or brushes.
- 4. Final Rinse: Thoroughly rinse with distilled water three times to remove all cleaning agents.
- 5. Drying: Place upside down on clean, lint-free absorbent paper. Allow to air dry completely before storage.
Особые указания для безвоздушных кювет
Sealing Components
Clean PTFE stoppers and ground glass joints separately with appropriate solvents. Ensure complete drying before reassembly.
Ультразвуковая очистка
For stubborn contaminants, ultrasonic cleaning is recommended. Place the cuvette with matte surfaces facing downward in the ultrasonic bath.
Special Contaminants
For oil/grease, use petroleum ether. For dye residues like chromazurol, use dilute nitric acid (1:2).
Хранение
Store cleaned and dried cuvettes in their original protective cases. Keep in a dust-free environment.
Handling
Always handle with gloves to prevent fingerprints and skin oils from contaminating optical surfaces.
· Dilute hydrochloric acid (1:2) for inorganic residues
· Specialized cuvette cleaning solution (limited exposure time: 10 minutes max)
Need Technical Consultation for Your Air Free Quartz Cuvette Requirements?
Почему стоит сотрудничать с TOQUARTZ
Прямое преимущество фабрики
Являясь прямым производителем, мы можем отказаться от многочисленных промежуточных звеньев.
Инженерная экспертиза
Техническая команда сопровождает клиентов от выбора материала до оптимизации конструкции, воплощая спецификации в готовые изделия.
Гибкое производство
Выполнение стандартных и индивидуальных заказов с помощью опыта работы с мелкими партиями и тщательного создания прототипов для соблюдения сроков.
Качество
Обеспечение
Трехступенчатая проверка перед отгрузкой:
1. точность размеров,
2. чистота материала ,
3. пороговые значения производительности
Глобальная цепочка поставок
Надежная глобальная логистика в промышленные центры (приоритет DE/US/JP/KR) с отслеживаемыми сроками.
Восстановленные продукты
Как специализированный производитель с прямыми заводскими возможностями, TOQUARTZ предлагает как стандартные, так и индивидуальные кварцевые решения с инженерной поддержкой на протяжении всего процесса спецификации и реализации.
ЧАСТО ЗАДАВАЕМЫЕ ВОПРОСЫ
Q: What is the wavelength range for your air free quartz cuvettes?
A: TOQUARTZ® air free quartz cuvettes provide excellent transmission across the 120nm to 4500nm wavelength range, making them suitable for UV, visible, and IR spectroscopy applications. The quartz material has no absorption peaks throughout this range, ensuring accurate spectral data.
Q: What is the proper quartz cuvette cleaning procedure to maintain optical performance?
A: For standard cleaning, rinse with distilled water immediately after use, then clean with an ethanol-water (1:1) mixture for organic contaminants or dilute HCl (1:2) for inorganic residues. Rinse thoroughly with distilled water three times, and air dry upside down on lint-free paper. Never use alkaline solutions, abrasives, or hydrofluoric acid, as these can damage the quartz surface.
Q: What types of sealing mechanisms are available for your air free quartz cuvettes?
A: TOQUARTZ® standard air free quartz cuvettes come with PTFE stoppers or ground glass joints that provide reliable gas-tight sealing. We also offer custom sealing options including specialized valves, septum ports for sample injection, compression fittings, and connectors compatible with standard laboratory equipment.
Q:What is the vacuum quartz cuvette solvent compatibility range?
A: TOQUARTZ® quartz cuvettes are compatible with most laboratory solvents including water, alcohols, acetone, chloroform, DMSO, acids (except HF), and bases. The high-purity quartz (99.995% SiO₂) provides excellent chemical resistance, though prolonged exposure to hydrofluoric acid or high-concentration fluoride solutions should be avoided.
Q: What is the typical quartz cuvette absorbance range for your products?
A: TOQUARTZ® vacuum quartz cuvettes support an absorbance range from 0.01 to 3.0 AU (Absorbance Units), depending on the path length selected. The high optical clarity and precision of our quartz material ensures accurate absorbance measurements across this range with minimal stray light interference.
Свяжитесь с нашей командой инженеров для получения технической консультации и определения цены. Мы поможем вам выбрать оптимальные характеристики для ваших требований.