Bubble-Minimizing Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge -TOQUARTZ®
Features of Quartz Micro Fluorescence Cuvette with
Open Top and Slanted Edge
TOQUARTZ® high-purity quartz micro fluorescence cuvettes are designed to deliver exceptional performance for precision spectroscopy applications. Each cuvette is manufactured to exacting standards to ensure consistent results across your research and testing protocols.
Precision Slanted Edge Design
ngineered for easy sample loading and reduced bubble formation, minimizing experimental errors during critical research.
광학 성능
Transmission range of 200-2500nm with no absorption peaks, making it ideal for UV-VIS-NIR spectroscopy applications.
내화학성
Maintains stability against acids, bases, and corrosive solutions, ensuring longevity even in harsh chemical environments.
열 안정성
Withstands temperatures up to 100°C, suitable for various thermal applications and experimental conditions.

- SiO2 순도 ≥99.98%, 최대 99.995%
- 독한 시약에 대한 내화학성
- 사용 가능한 사용자 지정 서비스
Technical Specifications & Dimensions of Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge
기술 사양
매개변수 | 사양 |
재료 | High-purity quartz (≥99.98% SiO2, max. up to 99.995%) |
인장 강도 | 50 MPa |
밀도 | 2.2g/cm³ |
열팽창 계수 | 5.5×10-7/℃ |
표면 마감 | Optical polish on all four sides |
내산성 | 우수(HF 제외) |
알칼리 저항 | 최대 pH 12까지 양호 |
용매 호환성 | 대부분의 유기 용매와 호환 가능 |
생체 적합성 | 비활성, 생물학적 시료와 비반응성 |
전송 범위 | 200-2500nm |
UV 차단 | <190nm |
굴절률 | 589.3nm에서 1.46 |
사이즈 차트

모델 | 설명 | 파장 | 경로 길이 | 볼륨 | 열 안정성 | 개요 차원 |
AT-BSM-4020 | 140μl Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge | 200nm-2500nm | 1mm/4mm | 140μl | 100℃ | 12.5×12.5×45mm |
TOQUARTZ® Solving Laboratory Challenges with Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge
Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge in Single-Cell Fluorescence Imaging Chambers
주요 이점
-
Multi-angle excitation enabled by 4-sided optical access
Allows 360° fluorescence excitation and emission collection, improving signal acquisition by up to 28% in confocal setups. -
Slanted edge supports gentle cell suspension loading
Reduces shear stress during pipetting, preserving >95% cell viability in microfluidic chambers. -
No-cap design eliminates vertical optical obstruction
Ensures uninterrupted Z-axis imaging in upright and inverted fluorescence microscopes.
TOQUARTZ® 솔루션
A German university lab conducting single-cell calcium imaging reported 22% signal loss due to sidewall refraction in standard 2-window cuvettes. After switching to TOQUARTZ®’s 4-sided transparent, open-top slanted cuvettes, signal-to-noise ratio improved by 31%, and cell viability during loading increased from 87% to 96%, enabling more accurate kinetic tracking of intracellular events.
Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge in Automated Liquid Handling Systems for High-Throughput Screening
주요 이점
-
Slanted edge aligns pipette tips automatically
Reduces robotic tip misalignment errors by 85% in automated dispensing systems. -
Open-top design prevents pipette head collisions
Eliminates vertical clearance issues in 96-well robotic platforms with <15mm Z-axis tolerance. -
Bubble-free loading improves assay reproducibility
Decreases fluorescence signal variability by 22% in enzyme inhibition assays.
TOQUARTZ® 솔루션
A US-based biotech CRO using Tecan EVO robots faced a 14% pipetting failure rate due to tip collisions with capped cuvettes. After adopting TOQUARTZ® open-top slanted cuvettes, failure rates dropped to 1.8%, and assay throughput increased by 19%, saving over $3,800/month in reagent waste and reruns.
Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge in Photobleaching Kinetics and Time-Resolved Fluorescence Decay Studies
주요 이점
-
Open-top allows sub-5s sample exchange between runs
Reduces inter-run delay by 42% in time-sensitive decay experiments. -
Slanted edge enables non-disruptive injection
Minimizes optical path disturbance, maintaining <2% baseline drift across runs. -
4-side polish eliminates internal reflection artifacts
Improves decay curve linearity by 18% in picosecond-resolved fluorescence studies.
TOQUARTZ® 솔루션
A photophysics lab in Kyoto University reported 17% curve distortion due to internal reflections in standard 2-polish cuvettes. Switching to TOQUARTZ® 4-polish, open-top slanted cuvettes reduced distortion to under 3%, and sample exchange time dropped from 12s to 6.8s, enabling higher temporal resolution in photobleaching kinetics.
TOQUARTZ® Customization Options for Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge
Custom Dimensional Modifications
- Customized path length options
- Sample volume variations
- Custom slanted edge angles for specific loading requirements
- Modified height and width dimensions for instrument compatibility
Material and Surface Options
- Ultra-high purity quartz (≥99.98% SiO₂, max. up to 99.995%) for demanding applications
- Specialized optical window selection
- 표면 처리 옵션
- 특정 파장 범위를 위한 반사 방지 코팅
사용자 지정 프로세스
- Initial consultation to understand your application requirements
- Technical drawing review and feasibility assessment
- Prototype development and validation (for new designs)
- 테스트를 위한 소량 생산
- 종합적인 품질 관리를 통한 완벽한 생산
Usage Guide of Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge
Sample Loading Procedure
- Clean and dry the cuvette thoroughly before use.
- Using a micropipette, slowly dispense sample onto the slanted edge.
- Allow liquid to flow down gradually to avoid bubble formation.
- Verify that the sample volume completely fills the measurement zone.
- Place carefully in instrument holder, aligning with light path.
중요 주의사항
- Avoid thermal shock – allow cuvette to equilibrate to room temperature before use.
- Do not exceed 100°C thermal limit to prevent damage.
- Never use abrasive materials for cleaning.
- Avoid hydrofluoric acid (HF) which can etch quartz surfaces.
- Inspect for chips or cracks before each use; damaged cuvettes may lead to inaccurate results.
청소 및 유지 관리
- Daily Cleaning: Rinse with deionized water followed by analytical grade methanol or ethanol.
- For Protein Residues: Use 1% laboratory detergent solution, then rinse thoroughly.
- For Stubborn Contaminants: Soak in 10% nitric acid solution for 30 minutes (avoid HF acid).
- 건조 중입니다: Use filtered compressed air or nitrogen gas; avoid wiping optical surfaces.
- 저장소: Store in original packaging or dust-free container.
- 처리: Always handle by edges, never touch optical surfaces.
Need Technical Consultation for Your Quartz Micro Fluorescence Cuvette Requirements?
With experience serving research institutions worldwide, we can recommend the optimal solution for your specific needs.
토쿼츠와 파트너 관계를 맺어야 하는 이유
직접 공장 이점
직접 제조업체로서 수많은 중간 단계를 생략할 수 있습니다.
엔지니어링 전문성
기술팀은 재료 선택부터 디자인 최적화까지 고객을 안내하고 사양을 결과물로 변환합니다.
유연한 제조
소량 전문성과 엄격한 프로토타입 제작을 통해 표준 및 맞춤형 주문을 처리하여 긴급한 마감 기한을 맞출 수 있습니다.
품질
보증
배송 전 3단계 유효성 검사:
1. 치수 정확도,
2. 재료 순도 ,
3. 성능 임계값
글로벌 공급망
추적 가능한 마일스톤을 통해 산업 허브로의 안정적인 글로벌 물류(DE/US/JP/KR 우선순위)를 제공합니다.
삭제된 제품
직접 공장 역량을 갖춘 전문 제조업체인 TOQUARTZ는 사양 및 구현 프로세스 전반에 걸쳐 엔지니어링 지원을 통해 표준 및 맞춤형 쿼츠 솔루션을 모두 제공합니다.
자주 묻는 질문
Q: What are the advantages of four-sided optical transparency in the Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge?
A: The four-sided optical transparency allows multi-angle excitation and emission detection, which is essential for single-cell imaging, confocal microscopy, and time-resolved fluorescence studies requiring full-spectrum access.
Q: Will the open-top design of the Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge cause sample evaporation during long experiments?
A: For short to mid-duration assays, evaporation is minimal due to the small surface area. For longer runs, we recommend using a compatible sealing film or placing the cuvette in a humidity-controlled chamber.
Q: How does the slanted edge of the Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge improve pipetting accuracy?
A: The slanted edge guides the pipette tip naturally into the chamber, reducing the risk of tip misalignment and minimizing bubble formation during sample loading, especially in automated systems.
Q: How does the open-top design of the Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge affect contamination risk?
A: While open-top designs are more exposed, proper lab protocols (e.g., using filtered pipette tips and clean benches) effectively mitigate contamination risks. The benefit is faster access and easier cleaning.
Q: Can the Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge be used for kinetic assays requiring rapid sample exchange?
A: Yes, the open-top design allows sub-5-second sample replacement, making it ideal for kinetic fluorescence assays and photobleaching studies where timing is critical.
기술 상담 및 가격 책정은 엔지니어링 팀에 문의하세요. 애플리케이션 요구 사항에 맞는 최적의 사양을 선택할 수 있도록 도와드리겠습니다.