UV Standard Fused Quartz Cuvette Cell Level Bottom with Lid -TOQUARTZ®

High-purity (99.98%+ SiO₂) Standard Fused Quartz UV Cuvette with level bottom and lid for precise spectrophotometer measurements.

Features 10mm path length, 3.5ml volume, and excellent transmission in 200-2500nm wavelength range. Ideal for laboratory analysis, pharmaceutical R&D, and environmental testing.
Kein MOQ
Kundenspezifisches Design
Fabrik direkt
Technische Unterstützung

Features of UV Standard Quartz Cuvette Cell Level Bottom

TOQUARTZ® UV Standard Fused Quartz Cuvette Cells with Level Bottom and Lid are engineered from high-purity fused silica for precise spectroscopic analysis applications. These optical components deliver exceptional performance across the UV-Vis-NIR spectrum while maintaining chemical resistance and thermal stability.

Optische Eigenschaften

Design-Merkmale

Standard UV quartz cuvette with transparent walls
TOQUARTZ® UV Standard Fused Quartz Cuvette Cell Level Bottom

Technische Daten und Abmessungen von
Standard Fused Quartz Glass Cuvette Level Bottom

TOQUARTZ® Standard Quartz UV Cuvette with Level Bottom and Lid is manufactured to precise specifications for compatibility with standard spectrophotometer instruments. All dimensions are quality controlled to ensure consistent performance in laboratory settings.

Technical Specifications of Standard Fused Quartz Cuvette UV Cell Level Bottom

Physikalische Eigenschaften

ParameterWert / BereichUnit / Notes
MaterialFused Quartz (≥99.995% SiO₂)High-purity synthetic silica
Dichte2.2g/cm³
Härte (Mohs-Skala)5.5-6-
Elastizitätsmodul72GPa
Querkontraktionszahl0.17-
Druckfestigkeit≥1100MPa
Biegefestigkeit≥50MPa
Fracture Toughness0.8–0.9MPa·m½
Wärmeleitfähigkeit1.3W/m·K (at 20°C)
Wärmeausdehnungskoeffizient5.5 × 10-⁷/K (20–300°C)
Maximale Betriebstemperatur1100°C (continuous use)
Erweichungspunkt1665°C
Glühpunkt1215°C
Dehnungspunkt1120°C
Pfadlänge10.00 ± 0.10mm
Äußere Abmessungen12.5 × 12.5 × 45mm (W × D × H)
Internes Volumen3.5ml
Wanddickentoleranz±0.10mm
Parallelität≤0.10mm
DeckeltypFlat lid or PTFE screw capOptional

Chemische Eigenschaften

ParameterValue / CompatibilityAnmerkungen
SäurebeständigkeitAusgezeichnetExcept HF and hot H₃PO₄
AlkalibeständigkeitGutAvoid prolonged exposure to strong bases
Beständigkeit gegen organische LösungsmittelAusgezeichnetCompatible with alcohols, ketones, DMSO, etc.
Wasserabsorption0%
Surface ReactivitySehr niedrigInert to most chemical reagents
AutoclavableJaWith lid removed if plastic
Cleaning CompatibilityCompatible with dilute acids, detergents, ethanolAvoid abrasive materials

Optische Eigenschaften

ParameterWert / BereichUnit / Notes
Wellenlänge Übertragungsbereich200 – 2500nm
UV-Grenzwert175 – 180nm
Transmittance @ 200nm≥80%Paired testing
Transmittance @ 220–250nm≥85%Typical
Transmittance @ 350–800nm≥90%Typical
Refractive Index @ 546nm1.458-
DoppelbrechungKeineIsotropes Material
Absorbance Range (Recommended)0 – 3.0A (Absorbance Units)
Qualität der OberflächeScratch-free, bubble-freeOptical polish on 2 sides
Optische Fenster2 sides polished, 2 sides frostedStandard for UV-Vis cuvettes
Fluoreszenz HintergrundVernachlässigbarSuitable for fluorescence spectroscopy

Size of of Standard Fused Quartz UV Cuvette Level Bottom with Lid

3.5ml UV Standard Quartz Cuvette Sample Cell Level Bottom with Lid
ModellBeschreibungWellenlängePfadlängeBandDurchlässigkeitUmriss Dimension
AT-BSM-0563.5ml UV Standard Quarzküvette Küvettenboden mit Deckel200nm-2500nm10mm3,5ml>80% (gepaarte Tests)12,5×12,5x45mm
Hinweis: Wir bieten kundenspezifische Spezifikationen an, um Ihre spezifischen Anforderungen zu erfüllen. Kontaktieren Sie unser Ingenieurteam für eine Beratung.

TOQUARTZ® Lösen analytischer Herausforderungen mit
Standard Fused Quartz Round Bottom UV Cuvette

Standard Fused Quartz UV Cuvette Level Bottom in Pharmaceutical Research

In pharmaceutical research laboratories, UV-Vis spectroscopy is essential for drug development, quality control, and stability testing. Scientists require cuvettes with consistent optical properties and high chemical resistance to analyze various formulations and active ingredients across the UV spectrum. Reliable absorbance measurements are critical for determining concentration, purity, and reaction kinetics.

Die wichtigsten Vorteile

TOQUARTZ®-Lösung

A US-based pharma lab reported 3.2% absorbance deviation using generic cuvettes in API quantification at 220nm.

TOQUARTZ® supplied cuvettes with certified ±0.1mm path length and ≥85% UV transmittance, reducing deviation to 0.6% and passing FDA validation.

Standard Fused Quartz UV Cuvette Level Bottom for Precision Instrument Manufacturing

Spectrophotometer manufacturers require high-precision cuvettes for instrument calibration, quality control, and as standard accessories for their analytical equipment. These companies need reliable components with consistent dimensions and optical properties to ensure their instruments deliver accurate results to end users. Dimensional consistency is critical for proper fit in instrument holders and sample changers.

Die wichtigsten Vorteile

TOQUARTZ®-Lösung

A German OEM faced 11% rejection rate due to cuvette misfit in auto-sampler trays. TOQUARTZ® delivered cuvettes with certified ±0.1mm tolerance and parallelism ≤0.1mm, reducing rejection to <1% and improving assembly efficiency.

Standard Quartz Cuvette UV Cell Level Bottom in Environmental Testing

Environmental testing laboratories analyze water, soil, and air samples for contaminants, requiring reliable and chemically resistant cuvettes for UV-Vis spectroscopy. These facilities need components that can withstand varied sample matrices and aggressive cleaning protocols while delivering consistent analytical results. High throughput operations demand durable cuvettes that maintain performance over numerous analysis cycles.

Die wichtigsten Vorteile

TOQUARTZ®-Lösung

A Canadian water lab replaced cuvettes every 3 months due to acid etching from daily HNO₃ cleaning.

TOQUARTZ® cuvettes retained >95% clarity after 6 months, cutting replacement frequency by 66% and saving $2,400/year.

Anpassungsdienste für TOQUARTZ®
Standard Quartz Glass UV Cuvette Level Bottom

TOQUARTZ® bietet spezielle Anpassungsdienste für Standard-Quarz-UV-Küvetten an, um spezielle Anwendungsanforderungen zu erfüllen, die über die Standardkonfigurationen hinausgehen.

Dimensionale Anpassung

Feature Modifications

Specialty Applications

TOQUARTZ®-Anpassung Designprozess

Anforderungsanalyse

TOQUARTZ® engineers begin by understanding your specific application needs for UV Standard Fused Quartz Cuvette Cell Level Bottom with Lid. This includes wavelength range, sample type, instrument compatibility, and volume constraints.

Technical Drawing Development

We create detailed CAD drawings of the customized cuvette, including lid type, path length, and external dimensions. All drawings are tailored to your UV-Vis spectroscopy setup and reviewed for feasibility.

Prototype Fabrication

A prototype of the custom UV Standard Fused Quartz Cuvette Cell Level Bottom with Lid is produced within 7–14 days. This allows you to validate fit, optical performance, and compatibility before mass production.

Optical and Dimensional Testing

Each prototype undergoes strict testing for path length accuracy (±0.1mm), UV transmittance (>80% @200nm), and dimensional tolerance. We ensure the cuvette meets your analytical precision requirements.

Batch Production and Delivery

Once approved, we proceed with batch manufacturing under ISO-level quality control. Your custom UV Standard Fused Quartz Cuvette Cell Level Bottom with Lid is delivered with full documentation and traceability.

Usage Guide of UV Standard Fused Quartz Cuvette Cell Level Bottom

Proper handling, usage, and maintenance of UV Standard Fused Quartz Cuvettes ensure optimal performance and extended service life for your spectroscopic applications.

Reinigung und Wartung

Proper Handling and Usage

Leitfaden zur Lösungsmittelkompatibilität

UV Standard Fused Quartz Cuvettes are compatible with most common laboratory solvents and reagents, with the following considerations:
Solvent TypeKompatibilitätAnmerkungen
Water (DI, tap, saline)AusgezeichnetNo limitations
Alcohols (methanol, ethanol, isopropanol)AusgezeichnetNo limitations
Acetone, acetonitrileAusgezeichnetNo limitations
Most acids (HCl, H₂SO₄, HNO₃)GutAvoid prolonged exposure to concentrated acids
Bases (NaOH, KOH)GutAvoid prolonged exposure to concentrated bases
DMSO, DMFAusgezeichnetNo limitations
Hydrofluoric acid (HF)Nicht KompatibelWill etch and dissolve quartz
Hot phosphoric acidNicht KompatibelWill attack quartz at elevated temperatures

Need Expert Guidance for Your UV Spectroscopy Applications?

Our engineers provide technical consultation on Standard Quartz UV Cuvette selection,
customization options, and integration with your analytical instruments.

Whether you need standard products or custom solutions, we're ready to support your laboratory needs.

Warum eine Partnerschaft mit TOQUARTZ

Vorteil der direkten Fabrik

Als direkter Hersteller können wir die zahlreichen Zwischenstufen ausschalten.

Technische Kompetenz

Das technische Team begleitet die Kunden von der Materialauswahl bis zur Designoptimierung und setzt die Spezifikationen in Ergebnisse um.

Flexible Fertigung

Bearbeitung von Standard- und kundenspezifischen Aufträgen mit Hilfe von Kleinserien und Prototyping, um dringende Fristen einzuhalten.

Qualität
Versicherung

3-Stufen-Validierung vor dem Versand:
1. Maßhaltigkeit,
2. Materialreinheit ,
3. Leistungsschwellen

Globale Lieferkette

Zuverlässige globale Logistik zu den industriellen Zentren (Priorität DE/US/JP/KR) mit nachvollziehbaren Meilensteinen.

FAQ

Q: Why are UV Standard Fused Quartz Cuvette Cell Level Bottom with Lid used in UV spectroscopy?

A: Fused quartz cuvettes Cuvettes Level Bottom with Lid are essential for UV spectroscopy because they provide exceptional transparency in the ultraviolet region (down to 200nm), unlike regular glass which absorbs UV light. The high-purity quartz material (max. up to 99.995% SiO₂) ensures minimal interference with measurements, while the standardized dimensions (particularly the precise 10mm path length) enable accurate and reproducible quantitative analysis across different instruments. The level bottom and lid further improve measurement stability and sample integrity.

A: TOQUARTZ® Standard Quartz UV Cuvettes Cuvettes Level Bottom with Lid provide excellent transmission from 200nm to 2500nm, covering the ultraviolet, visible, and near-infrared regions of the spectrum. This broad range makes them suitable for diverse spectroscopic applications, from UV absorbance of proteins and nucleic acids to visible colorimetric assays and even some NIR applications. The transmittance at 200nm exceeds 80%, which is critical for sensitive UV measurements.

A: Standard Quartz UV Cuvettes Cuvettes Level Bottom with Lid are widely used in numerous applications, including: protein and nucleic acid quantification in molecular biology; pharmaceutical drug development and quality control; environmental water quality monitoring; chemical concentration determination; kinetics studies of chemical reactions; food and beverage quality analysis; forensic sample testing; clinical diagnostics of biological samples; materials science research; and educational laboratory demonstrations. Their versatility stems from excellent UV transmission properties, chemical resistance, and dimensional precision, making them essential tools across scientific disciplines where spectroscopic analysis is required.

A: Proper orientation of Standard Quartz UV Cuvettes Cuvettes Level Bottom with Lid is crucial for accurate measurements. The cuvette should be placed so that the transparent optical windows face the light path, while the frosted or ribbed sides are perpendicular to the beam. Most spectrophotometers have a fixed light path direction, and our cuvettes feature orientation marks to ensure correct placement. For our standard two-window cuvettes, the polished optical windows should face the incident light beam and detector. Incorrect orientation could result in light passing through the non-optical sides, causing scattering and measurement errors. Always refer to your instrument’s manual for specific cuvette orientation requirements.

A: The practical absorbance range for our Standard Quartz UV Cuvettes Cuvettes Level Bottom with Lid is typically 0 to 3.0 absorbance units (A). For most accurate results, measurements are recommended in the 0.1-1.0 A range, where the relationship between concentration and absorbance is most linear according to the Beer-Lambert Law. Beyond 2.0 A, precision may decrease due to reduced light reaching the detector. For samples with higher absorbance, we recommend either dilution or using cuvettes with shorter path lengths (available in our custom offerings). Our cuvettes are tested to ensure minimal intrinsic absorbance, providing a clean baseline for accurate sample measurements.

Wenden Sie sich für technische Beratung und Preisgestaltung an unser Ingenieurteam. Wir helfen Ihnen bei der Auswahl der optimalen Spezifikationen für Ihre Anwendungsanforderungen.

de_DEDeutsch
Nach oben blättern

Jetzt ein schnelles Angebot anfordern

Sagen Sie uns, was Sie brauchen - Sie erhalten maßgeschneiderte Preise und Vorlaufzeiten innerhalb von 6 Stunden.

* Prüfen Sie die E-Mail nach dem Absenden. Nicht erhalten? Überprüfen Sie die Adresse.