1. Startseite
  2. /
  3. Typen
  4. /
  5. Quarz-Küvette
  6. /
  7. Quarz-Durchflussküvette
  8. /
  9. Enhanced Sensitivity Black Wall...

Enhanced Sensitivity Black Wall Fluorescence Flow Cuvette with Glass Tubes for Chromatography -TOQUARTZ®

TOQUARTZ® Black Wall Fluorescence Flow Cuvette with Glass Tubes delivers precision fluorescence measurements for analytical laboratories. Manufactured from high-purity quartz with excellent transmission range (190-2500nm) and light-absorbing black walls for enhanced measurement sensitivity. Ideal for research institutions, equipment manufacturers, and analytical laboratories requiring reliable flow cells for fluorescence detection.
Kein MOQ
Kundenspezifisches Design
Fabrik direkt
Technische Unterstützung

Features of Black Wall Fluorescence Flow Cuvette with Glass Tube

TOQUARTZ® Black Wall Fluorescence Flow Cuvette with Glass Tubes combines advanced optical properties with precise engineering to deliver superior performance for fluorescence analysis applications. Each unit is manufactured with attention to detail to ensure consistent quality and reliable results.

Lichtübertragung

Provides excellent transmission across 190-2500nm wavelength range, ensuring accurate and reliable measurement results. The high-purity quartz material enables transparency in both UV and visible light regions.

Schwarzes Wanddesign

Black walls effectively absorb scattered light, minimizing stray light interference and enhancing measurement sensitivity. This design is particularly beneficial for low-concentration fluorescence analysis.

Hochreiner Quarz

Manufactured from high-purity quartz material (up to 99.995% purity) ensuring consistent quality and stability. The material properties provide excellent resistance to chemical corrosion and thermal shock.

Glass Tube Connections

Integrated glass tube connections facilitate easy integration with existing laboratory setups. These connections ensure secure, leak-free operation for continuous flow applications.

Precision Quartz Black Wall Fluorescence Flow Cuvette with Glass Tubes for Reliable Fluorescence Detection
TOQUARTZ® Black Wall Fluorescence Flow Cuvette with Glass Tube

Technical Specifications & Dimensions of Black Wall Fluorescence Flow Cuvette with Glass Tube

TOQUARTZ® Black Wall Fluorescence Flow Cuvette with Glass Tubes is engineered to precise specifications to ensure optimal performance in fluorescence measurement applications. The following tables detail the physical, chemical, and optical properties of this product.

Technische Daten

EigentumWertPrüfverfahren
1. Physikalische Eigenschaften
Maximale Betriebstemperatur1100°CKurzzeitige Exposition
Wärmeausdehnungskoeffizient5.5 × 10-7/℃20-320°C range
2. Chemische Eigenschaften
Materielle ReinheitBis zu 99,995%Hochreiner Quarz
Chemische BeständigkeitAusgezeichnetResistant to most acids and organic solvents
Hydrolytische ResistenzKlasse 1ISO 719 standard
Wasserabsorption< 0,01%At 20℃
OH Inhalt< 30 ppmFor standard grade
3. Optische Eigenschaften
Übertragungsbereich190-2500 nmCovers UV through NIR
UV Cutoff Wavelength185 nm10 mm path length
Brechungsindex1.458 at 546.1 nmBei 20°C
Stray Light Absorption> 99%By black walls
Optische Homogenität< 5 × 10-6High grade optical quality
Optisches Finish< 0.2 nm RMSOptical windows

Größentabelle

250μl Black Wall Quartz Fluorescence Flow Cuvette with Glass Tubes
ModellBeschreibungPfadlängeBandUmriss Dimension
AT-BSM-8030250μl Black Wall Quartz Fluorescence Flow Cuvette with Glass Tubes10mm250μl12,5×12,5x45mm
Hinweis: Wir bieten kundenspezifische Spezifikationen an, um Ihre spezifischen Anforderungen zu erfüllen. Kontaktieren Sie unser Ingenieurteam für eine Beratung.

Solving Analytical Challenges with TOQUARTZ® Black Wall Fluorescence Flow Cuvette with Glass Tube

Post-Column Fluorescence in HPLC/UPLC (trace organics & drug impurities)

Eluent exits the column at a constant flow and passes through the black-walled quartz fluorescence flow cuvette with glass tubes inside an external FL detector to quantify PAHs, biogenic amines, AFD derivatives, genotoxic impurities, and metabolites where narrow peaks demand minimal dispersion. Any dead volume or stray light broadens peaks and raises noise; solvent background and internal reflections cause baseline drift and poorer LOD/LOQ; frequent mobile-phase changes create carryover and “memory” effects.

Die wichtigsten Vorteile

TOQUARTZ®-Lösung

A pharma QC lab quantified a genotoxic impurity (target 0.1 ppm) post-column with FL detection at 365/455 nm. Switching to the TOQUARTZ black-walled flow cuvette reduced baseline noise from 0.26 to 0.15 mV RMS and peak width increased only 3% versus 11% with their prior cell. LOQ improved 2.6× (0.078→0.030 ppm) and carryover fell to 0.03% after a 2-minute rinse. Batch release time dropped by 18% due to fewer repeat injections.

Flow Injection Analysis (FIA) & Online Water-Quality Fluorometry

Environmental/process streams mix online with fluorescent reagents (e.g., fluorescein, rhodamine WT, metal chelates) and are pumped continuously through the black-walled quartz flow cuvette for real-time quantification in plants or field stations. Complex matrices and turbidity amplify scatter; bubbles and biofouling cause spikes and signal jumps; outdoor/long-duty systems need chemically inert, corrosion-proof optics that clean and swap quickly.

Die wichtigsten Vorteile

TOQUARTZ®-Lösung

A municipal plant running rhodamine-WT tracer FIA experienced false spikes during high-NTU events. After adopting the TOQUARTZ black-walled flow cuvette, spike incidents fell by 83% and 90-day uptime rose from 97.1% to 99.5%. MDL improved from 0.08 to 0.03 µg/L at 0.8 mL/min. Weekly 5-minute CIP kept drift within ±0.5% with no unscheduled maintenance.

Bioprocess PAT Bypass for Real-Time NADH/Tryptophan Fluorescence

A sterile bypass loop draws fermenter or cell-culture broth through the black-walled quartz fluorescence flow cuvette with glass tubes to track NADH/FAD or protein-related fluorescence for viability, metabolism trending, feed control, and endpoint decisions. In-situ probes foul and are hard to sanitize; turbid broths generate intense scatter and unstable backgrounds; parts must survive repeated SIP/CIP with reliable seals and low adsorption.

Die wichtigsten Vorteile

TOQUARTZ®-Lösung

A biotech fermenter (E. coli fed-batch) monitored NADH online via a sterile bypass. With the TOQUARTZ black-walled cuvette, baseline wander during high cell density fell 48% and correlation to offline OD600 improved (R² 0.76→0.93). The faster <1 s lag enabled feed-pump PID tuning that cut glucose overshoot by 22%. Across 12 weeks and 18 SIP cycles, no fouling-related recalibration was required.

TOQUARTZ® Customization Services for Black Wall Fluorescence Flow Cuvette with Glass Tube

TOQUARTZ® offers comprehensive customization services for our Black Wall Fluorescence Flow Cuvette with Glass Tubes to meet your specific application requirements. Our engineering team works closely with you to design and manufacture the optimal solution for your analytical challenges.

Dimensionale Anpassung

Tailored geometries for Black Wall Fluorescence Flow Cuvette with Glass Tubes.

Anschluss Anpassungen

Interface choices suit chromatographs, FIA manifolds, and bioprocess bypasses on Black Wall Fluorescence Flow Cuvette with Glass Tubes.

Material-Spezifikationen

Material options target optical stability, chemical resistance, and sanitation for Black Wall Fluorescence Flow Cuvette with Glass Tubes.

Gebrauchs- und Pflegehinweise

Proper handling, installation, and maintenance of your Black Wall Fluorescence Flow Cuvette with Glass Tubes will ensure optimal performance and extended service life. Follow these guidelines to maximize the value of your investment.

Handhabung und Installation

Reinigung und Wartung

Fehlersuche bei allgemeinen Problemen

AusgabeMögliche UrsacheLösung
Undichte VerbindungenImproper fitting or overtightened connectionReplace fittings, ensure proper size, apply even pressure
Decreased sensitivityWindow contamination or scratchesClean windows with optical solvent, replace if scratched
Air bubbles in flow pathImproper degassing or connection issueIncrease flow rate temporarily, check for loose fittings
Basislinien-DriftTemperature fluctuation or residual contaminationStabilize temperature, perform thorough cleaning

Need Custom Black Wall Fluorescence Flow Cuvettes?

Our engineering team can design and manufacture Black Wall Quartz Fluorescence Flow Cuvette with Glass Tube to your exact specifications.
Contact us today for a free consultation.

Warum eine Partnerschaft mit TOQUARTZ

Vorteil der direkten Fabrik

Als direkter Hersteller können wir die zahlreichen Zwischenstufen ausschalten.

Technische Kompetenz

Das technische Team begleitet die Kunden von der Materialauswahl bis zur Designoptimierung und setzt die Spezifikationen in Ergebnisse um.

Flexible Fertigung

Bearbeitung von Standard- und kundenspezifischen Aufträgen mit Hilfe von Kleinserien und Prototyping, um dringende Fristen einzuhalten.

Qualität
Versicherung

3-Stufen-Validierung vor dem Versand:
1. Maßhaltigkeit,
2. Materialreinheit ,
3. Leistungsschwellen

Globale Lieferkette

Zuverlässige globale Logistik zu den industriellen Zentren (Priorität DE/US/JP/KR) mit nachvollziehbaren Meilensteinen.

FAQ

Q: How does the Black Wall Fluorescence Flow Cuvette with Glass Tubes improve fluorescence sensitivity?

A: The black wall design of the Black Wall Fluorescence Flow Cuvette with Glass Tubes minimizes stray light and internal reflections, significantly enhancing fluorescence signal-to-noise ratios. This improves sensitivity, particularly in low-level fluorescence measurements. The black walls ensure that the measurement is not compromised by unwanted background light.

A: Yes, the Black Wall Fluorescence Flow Cuvette with Glass Tubes is ideal for HPLC/UPLC applications, especially in high-throughput environments. Its flow-through design ensures minimal sample dispersion, preserving chromatographic peak integrity. This results in more accurate and reproducible fluorescence measurements for trace impurities or metabolites.

A: The black wall minimizes scattered light from turbid samples, ensuring that the fluorescence signal remains clear. This is especially important when working with samples containing suspended particles, as it prevents false readings caused by scatter. It maintains accurate measurements even in complex matrices.

A: Yes, the Black Wall Fluorescence Flow Cuvette with Glass Tubes excels in low-concentration fluorescence detection. Its superior light absorption and minimized stray light enhance the detection of trace amounts of fluorescence signals, providing high sensitivity even for dilute samples.

A: The black wall design effectively absorbs stray light, preventing it from interfering with the fluorescence signal. This is critical in reducing background noise, especially in applications where precision is essential. It ensures that the detected signal is primarily from the sample, improving data quality.

Wenden Sie sich für technische Beratung und Preisgestaltung an unser Ingenieurteam. Wir helfen Ihnen bei der Auswahl der optimalen Spezifikationen für Ihre Anwendungsanforderungen.

de_DEDeutsch
Nach oben blättern

Jetzt ein schnelles Angebot anfordern

Sagen Sie uns, was Sie brauchen - Sie erhalten maßgeschneiderte Preise und Vorlaufzeiten innerhalb von 6 Stunden.

* Prüfen Sie die E-Mail nach dem Absenden. Nicht erhalten? Überprüfen Sie die Adresse.