Black Wall Quartz Flow-Through Cell with M6 Connectors for Laboratory Flow Analysis -TOQUARTZ®
Key Features of Black Wall Quartz Flow-Through Cell with M6 Connectors
TOQUARTZ® Black Wall Quartz Flow-Through Cells with M6 Connectors combine precision engineering with superior material properties to deliver reliable performance in demanding analytical applications.
الوضوح البصري
Manufactured from high-purity quartz material with excellent UV transmission range from 190 nm to 2500 nm, ensuring precise spectroscopic measurements across a wide wavelength range.
مقاومة المواد الكيميائية
Resistant to a wide range of chemicals including acids, bases, and organic solvents, making these cells suitable for diverse analytical chemistry applications and ensuring long service life.
M6 Connector Integration
Equipped with industry-standard M6 threaded connectors for seamless integration with existing flow systems, ensuring secure connections and minimizing the risk of leaks during continuous operation.

- نقاء SiO2 ≥99.98%، حتى 99.995%
- مقاومة المواد الكيميائية للكواشف القاسية
- خدمات التخصيص المتاحة
Technical Specifications & Dimensions of Black Wall Quartz Flow-Through Cell with M6 Connectors
المواصفات الفنية
المعلمة | المواصفات |
1. الخصائص الفيزيائية | |
المادة: | كوارتز عالي النقاء |
نقاء الكوارتز: | ≥99.981.98%، حتى 99.995% SiO2 |
Connector Type: | M6 threaded |
التمدد الحراري: | 5.5 × 10-7/درجة مئوية (20-320 درجة مئوية) |
تشطيب السطح: | مصقول بصرياً |
2. الخواص الكيميائية | |
مقاومة المواد الكيميائية: | ممتاز |
مقاومة الأحماض: | مرتفع (باستثناء التردد العالي) |
مقاومة القلويات: | جيد في درجة حرارة الغرفة |
توافق المذيبات: | Comprehensive |
امتصاص الماء: | ضئيل |
3. الخصائص البصرية | |
نطاق الإرسال: | 190-2500 نانومتر |
معامل الانكسار: | 1.458 (عند 546.1 نانومتر) |
قطع الأشعة فوق البنفسجية: | ~حوالي 170 نانومتر |
Scatter Reduction: | Black wall design |
جودة السطح: | 60-40 نقطة الصفر-حفر 60-40 |
جدول المقاسات

الطراز | الوصف | طول المسار | الحجم | بُعد المخطط التفصيلي |
AT-BSM-8002 | 32μl Laboratory Black Wall Quartz Flow-Through Cuvette with M6 Screw Connector | 10 مم | 32 ميكرولتر | 12.5 × 12.5 × 12.5 × 35 مم |

الطراز | الوصف | طول المسار | الحجم | بُعد المخطط التفصيلي |
AT-BSM-8037-3 | 32μl Black Wall Quartz Flow-Through Cuvette with M6 Connector | 10 مم | 32 ميكرولتر | 12.5 × 12.5 × 12.5 × 35 مم |

الطراز | الوصف | طول المسار | الحجم | بُعد المخطط التفصيلي |
AT-BSM-8036 | 60μl Black Wall Quartz Flow-Through Cuvette with M6 Threaded Connector | 1 مم | 60 ميكرولتر | 12.5 × 12.5 × 12.5 × 35 مم |

الطراز | الوصف | طول المسار | الحجم | Window Size |
AT-BSM-8036-1 | 100μl Black Wall Quartz Flow-Through Cuvette with M6 Connector, Optical Center Height 15mm | 3 مم | 100 ميكرولتر | 3x12mm |

الطراز | الوصف | طول المسار | الحجم | بُعد المخطط التفصيلي |
AT-BSM-8036-2 | 120μl Black Wall Quartz Flow-Through Cuvette with M6 Connector | 2 مم | 120 ميكرولتر | 12.5 × 12.5 × 12.5 × 35 مم |

الطراز | الوصف | طول المسار | الحجم | بُعد المخطط التفصيلي |
AT-BSM-8006 | 200μl Black Wall Quartz Flow-Through Cuvette with M6 Threaded Connector | 10 مم | 200 ميكرولتر | 12.5 × 12.5 × 12.5 × 35 مم |

الطراز | الوصف | طول المسار | الحجم | بُعد المخطط التفصيلي |
AT-BSM-8037-2 | 200μl Black Wall Quartz Flow-Through Cuvette with M6 Connector | 10 مم | 200 ميكرولتر | 12.5 × 12.5 × 12.5 × 35 مم |

الطراز | الوصف | طول المسار | الحجم | بُعد المخطط التفصيلي |
AT-BSM-8036-3 | 300μl Black Wall Quartz Flow-Through Cuvette with M6 Connector | 5 مم | 300 ميكرولتر | 12.5 × 12.5 × 12.5 × 35 مم |

الطراز | الوصف | طول المسار | الحجم | Window Size |
AT-BSM-8036-4 | 380μl Black Wall Quartz Flow-Through Cuvette with M6 Connector, Optical Center Height 15mm | 10 مم | 380μl | 3.5x11mm |

الطراز | الوصف | طول المسار | الحجم | بُعد المخطط التفصيلي |
AT-BSM-8037 | 400μl Black Wall Quartz Flow-Through Cuvette with M6 Connector | 10 مم | 400 ميكرولتر | 12.5 × 12.5 × 12.5 × 35 مم |

الطراز | الوصف | طول المسار | الحجم | Window Size |
AT-BSM-8036-5 | 440μl Black Wall Quartz Flow-Through Cuvette with M6 Connector, Optical Center Height 15mm | 10 مم | 440μl | 4x11mm |

الطراز | الوصف | طول المسار | الحجم | بُعد المخطط التفصيلي |
AT-BSM-8037-4 | 450μl Black Wall Quartz Flow-Through Cuvette with M6 Connector | 10 مم | 450 ميكرولتر | 12.5 × 12.5 × 12.5 × 35 مم |

الطراز | الوصف | طول المسار | الحجم | بُعد المخطط التفصيلي |
AT-BSM-8036-6 | 600μl Black Wall Quartz Flow-Through Cuvette with M6 Connector | 10 مم | 600 ميكرولتر | 12.5 × 12.5 × 12.5 × 35 مم |

الطراز | الوصف | طول المسار | الحجم | بُعد المخطط التفصيلي |
AT-BSM-8037-1 | 800μl Black Wall Quartz Flow-Through Cuvette with M6 Connector | 10 مم | 800 ميكرولتر | 12.5 × 12.5 × 12.5 × 35 مم |
Solving Analytical Challenges with TOQUARTZ® Black Wall Quartz Flow-Through Cell with M6 Connectors
Black Wall Quartz Flow-Through Cell with M6 Connector in Dissolution Testing Systems for Pharmaceutical QA
المزايا الرئيسية
-
Stray Light Reduction Efficiency
Black wall design reduces UV stray light interference by 87% at 260 nm, improving signal stability in real-time dissolution testing. -
Flow Path Uniformity
Internal channel deviation is controlled within ±0.05 mm, ensuring consistent sample exposure and absorbance reproducibility. -
Leak-Free M6 Integration
M6 threaded connectors withstand 1.5 bar pressure without leakage, verified in 48-hour continuous flow tests.
محلول توكارتز
A German pharmaceutical QA lab reported ±0.12 AU signal drift during 12-hour dissolution runs using standard cuvettes. After switching to TOQUARTZ® Black Wall Quartz Flow-Through Cell with M6 Connector, signal drift was reduced to ±0.02 AU, and connector leakage incidents dropped to zero across 60 test cycles. This improved batch release accuracy and reduced retesting by 35%.
Black Wall Quartz Flow-Through Cell with M6 Connector in Real-Time Bioprocess Monitoring for Fermentation Control
المزايا الرئيسية
-
Autoclave Cycle Durability
Withstands 121°C steam sterilization for 100+ cycles without optical degradation or seal failure. -
Biofilm-Resistant Surface Finish
Quartz surface roughness Ra < 0.02 μm minimizes microbial adhesion during long-term fermentation. -
Inline Port Compatibility
M6 connectors align with standard 1/16" PAT ports, enabling tool-free integration into bioreactor sampling loops.
محلول توكارتز
A South Korean biopharma plant experienced 18% downtime due to biofilm buildup in acrylic flow cells during 7-day fermentations. After adopting TOQUARTZ® Black Wall Quartz Flow-Through Cells, cleaning frequency dropped from every 48 hours to once per batch, and OD600 measurement drift was reduced by 70%, improving process yield consistency.
Black Wall Quartz Flow-Through Cell with M6 Connector in Trace Pollutant Detection in Online Water Quality Monitoring
المزايا الرئيسية
-
Background Signal Suppression
Black wall design reduces baseline noise by 0.015 AU in UV254 detection of nitrates in surface water. -
Optical Alignment Stability
Fixed optical center height of 15 mm ensures <0.1° angular deviation across 1000+ hours of field operation. -
Rapid Field Replacement
M6 connectors enable cell replacement in under 3 minutes without recalibration, verified in EPA-certified stations.
محلول توكارتز
A Canadian municipal water authority faced frequent recalibration (every 3 days) due to signal drift in standard flow cells. After deploying TOQUARTZ® Black Wall Quartz Flow-Through Cells, recalibration intervals extended to 14 days, and nitrate detection limits improved from 0.12 mg/L to 0.05 mg/L, meeting stricter provincial compliance standards.
TOQUARTZ® Customization Options for Black Wall Quartz Flow-Through Cell with M6 Connectors
Custom Optical Path & Volume
Clients often require precise control over light path and internal volume to match their detection sensitivity and sample throughput.
-
خيارات طول المسار
Tailored to match optical system geometry and resolution needs. -
Internal Volume Control
Designed for sample economy or high-throughput flow conditions. -
Window Positioning
Optimized for dual-beam or multi-angle detection setups.
Connector & Port Adaptation
We support connector customization to ensure seamless integration with existing fluidic or analytical systems.
-
Thread Type Matching
Compatible with industry-specific fittings and tubing standards. -
Port Orientation Design
Adjusted for vertical, horizontal, or angled flow configurations. -
Leak-Proof Assurance
Engineered for secure, tool-free installation and replacement.
Multi-Window & Detection Geometry
Specialized detection setups may require additional optical windows or non-standard beam paths.
-
Dual-Window Layout
Enables simultaneous absorbance and fluorescence measurements. -
Angular Beam Access
Supports 90° or 180° detection geometries for scattering analysis. -
Optical Center Height
Aligned with instrument-specific beam alignment requirements.
معالجة السطح والمواد
Surface finish and material enhancements improve chemical compatibility and reduce contamination risks.
-
Anti-Fouling Finish
Minimizes biofilm or residue accumulation during long-term use. -
Coating Compatibility
Supports hydrophobic or anti-reflective surface treatments. -
Chemical Resistance Boost
Enhanced for aggressive solvents or sterilization protocols.
إرشادات الاستخدام والعناية
إجراءات التثبيت
- Inspect the cell - Check for any damage, cracks, or optical imperfections before installation.
- Clean optical windows - Use lens-grade tissue with spectroscopic-grade solvent to remove any fingerprints or contaminants from optical surfaces.
- Prepare connectors - Ensure M6 connectors are clean and free from debris. Use appropriate PTFE tape if necessary for leak-free connections.
- توصيل الأنابيب - Hand-tighten the M6 connectors, then use a wrench to tighten an additional 1/4 turn maximum. Do not overtighten as this may damage the threads or cell body.
- Verify alignment - Ensure the cell is properly aligned with the light path in your instrument before securing in position.
- Flow test - Start with a low flow rate to verify connections are leak-free before proceeding to normal operating conditions.
Maintenance and Storage
- Regular cleaning - Flush the cell with appropriate solvent after each use to prevent sample buildup or contamination. For persistent residues, use a mild cleaning solution compatible with quartz material.
- Optical window care - Periodically inspect optical windows for clarity. Clean with lens-grade tissue and appropriate solvent as needed. Avoid abrasive materials that could scratch optical surfaces.
- Storage conditions - Store cells clean and dry in a dust-free container. For long-term storage, cap or seal M6 connectors to prevent dust entry.
- التوافق الكيميائي - While quartz is resistant to most chemicals, avoid prolonged exposure to hydrofluoric acid (HF) which can damage quartz surfaces.
- Thermal considerations - Allow cells to gradually reach operating temperature to prevent thermal shock. Similarly, allow cells to cool gradually after high-temperature applications.
استكشاف المشكلات الشائعة وإصلاحها
الإصدار | السبب المحتمل | الحل |
تسرب التوصيلات | ·Insufficient tightening ·Damaged threads ·Missing/damaged seals | ·Check and retighten connections ·Inspect threads for damage ·Replace seals if necessary ·Apply appropriate PTFE tape |
Decreased optical performance | ·Contaminated windows ·Sample deposits ·Scratched optical surfaces | ·Clean windows with appropriate solvent ·Flush system with cleaning solution ·Inspect for scratches (replace if necessary) |
Flow inconsistencies | ·Partial blockage ·Air bubbles ·Inconsistent pump pressure | ·Flush with solvent to remove blockages ·Degas mobile phase ·Check pump system ·Ensure proper cell orientation |
Expert Technical Support for Your Black Wall Quartz Flow-Through Cell with M6 Connector Applications
the optimal Black Wall Quartz Flow-Through Cell configuration for your specific analytical requirements.
لماذا الشراكة مع TOQUARTZ
ميزة المصنع المباشر
وبصفتنا شركة تصنيع مباشرة، يمكننا الاستغناء عن الروابط الوسيطة العديدة.
الخبرة الهندسية
يقوم الفريق التقني بتوجيه العملاء بدءاً من اختيار المواد إلى تحسين التصميم، وترجمة المواصفات إلى مخرجات.
التصنيع المرن
التعامل مع الطلبيات القياسية والمخصصة من خلال الخبرة في مجال الدُفعات الصغيرة والصرامة في وضع النماذج الأولية للوفاء بالمواعيد النهائية العاجلة.
الجودة
التأمين
التحقق من الصحة قبل الشحن في 3 خطوات:
1. دقة الأبعاد,
2. نقاء المادة,
3 - عتبات الأداء
سلسلة التوريد العالمية
خدمات لوجستية عالمية موثوقة إلى المراكز الصناعية (أولوية DE/US/JP/KR) مع مراحل إنجاز يمكن تتبعها.
المنتجات المستعادة
تقدم TOQUARTZ، بصفتها شركة تصنيع متخصصة تتمتع بقدرات المصنع المباشرة، حلول الكوارتز القياسية والمخصصة مع الدعم الهندسي طوال عملية تحديد المواصفات والتنفيذ.
الأسئلة الشائعة
Q: What is the benefit of using a Black Wall Quartz Flow-Through Cell with M6 Connector in UV-Vis applications?
A: The black wall structure effectively absorbs stray and scattered light, minimizing background interference. This enhances the accuracy of UV-Vis absorbance measurements in flow analysis. The Black Wall Quartz Flow-Through Cell with M6 Connector is ideal for applications requiring low signal noise. It provides higher signal-to-noise ratios compared to transparent wall cuvettes.
Q: Why is the M6 connector design important for this flow cell?
A: The M6 threaded connectors ensure secure and leak-free integration into lab fluid systems. They support easy connection with common PTFE tubing used in automated analytical platforms. The Black Wall Quartz Flow-Through Cell with M6 Connector minimizes dead volume and improves sample throughput stability. This feature is critical for online monitoring or continuous flow analysis.
Q: How does the black wall design improve measurement reliability in flow-through cells?
A: The black wall coating eliminates light reflections from the cuvette body, which can distort spectral data. It improves baseline stability and enhances sensitivity for low-concentration samples. The Black Wall Quartz Flow-Through Cell with M6 Connector ensures consistent optical performance even under variable flow conditions. This is essential for precision in long-run spectroscopic experiments.
Q: What is the typical optical path length of the Black Wall Quartz Flow-Through Cell with M6 Connector?
A: Standard models are available in 1mm, 5mm, and 10mm optical path lengths. Customization is also supported based on system requirements. The Black Wall Quartz Flow-Through Cell with M6 Connector is ideal for both narrow-path high-absorbance and wide-path low-concentration detection. All versions maintain optical center alignment for stable signal acquisition.
Q: Can the Black Wall Quartz Flow-Through Cell with M6 Connector withstand pressure or temperature fluctuations?
A: Yes, the cell is designed with durable quartz to tolerate moderate fluidic pressure. It can operate safely in temperature-controlled environments used in analytical labs. The Black Wall Quartz Flow-Through Cell with M6 Connector maintains dimensional and optical stability under typical operating conditions. Always confirm application parameters with the supplier for exact limits.