Bubble-Minimizing Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge -TOQUARTZ®

TOQUARTZ® High-purity quartz micro fluorescence cuvette featuring an open-top design with precision slanted edge for easy sample loading. Manufactured from optical-grade quartz (≥99.98% SiO₂). Ideal for DNA/RNA quantification, protein analysis, and ultra-low volume fluorescence spectroscopy applications.
لا يوجد موك
تصميم مخصص
المصنع مباشرة
الدعم الفني

Features of Quartz Micro Fluorescence Cuvette with
Open Top and Slanted Edge

TOQUARTZ® high-purity quartz micro fluorescence cuvettes are designed to deliver exceptional performance for precision spectroscopy applications. Each cuvette is manufactured to exacting standards to ensure consistent results across your research and testing protocols.

Precision Slanted Edge Design

ngineered for easy sample loading and reduced bubble formation, minimizing experimental errors during critical research.

الأداء البصري

Transmission range of 200-2500nm with no absorption peaks, making it ideal for UV-VIS-NIR spectroscopy applications.

مقاومة المواد الكيميائية

Maintains stability against acids, bases, and corrosive solutions, ensuring longevity even in harsh chemical environments.

الاستقرار الحراري

Withstands temperatures up to 100°C, suitable for various thermal applications and experimental conditions.

Low Volume Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge
TOQUARTZ® Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge

Technical Specifications & Dimensions of Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge

TOQUARTZ® quartz micro fluorescence cuvette is manufactured to precise specifications to ensure compatibility with standard laboratory equipment and consistent experimental results.

المواصفات الفنية

المعلمةالمواصفات
الموادHigh-purity quartz (≥99.98% SiO2, max. up to 99.995%)
قوة الشد50 ميجا باسكال
الكثافة2.2 جم/سم مكعب
معامل التمدد الحراري5.5×10-7/℃
تشطيب السطحOptical polish on all four sides
مقاومة الأحماضممتاز (باستثناء التردد العالي)
مقاومة القلوياتجيد حتى الرقم الهيدروجيني 12
توافق المذيباتمتوافق مع معظم المذيبات العضوية
التوافق الحيويخامل وغير تفاعلي مع العينات البيولوجية
نطاق الإرسال200-2500 نانومتر
قطع الأشعة فوق البنفسجية<190 نانومتر
معامل الانكسار1.46 على بعد 589.3 ميل بحري

جدول المقاسات

140μl Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge
الطرازالوصفالطول الموجيالمسار
الطول
الحجمالاستقرار الحراريبُعد المخطط التفصيلي
AT-BSM-4020140μl Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge200 نانومتر - 2500 نانومتر1mm/4mm140μl100℃12.5 × 12.5 × 12.5 × 45 مم
ملاحظة: نقدم مواصفات مخصصة لتلبية متطلباتك الخاصة. اتصل بفريقنا الهندسي للاستشارة.

TOQUARTZ® Solving Laboratory Challenges with Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge

Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge in Single-Cell Fluorescence Imaging Chambers

In single-cell fluorescence imaging, researchers often isolate and analyze individual cells in microfluidic or static chambers. These experiments require cuvettes with unobstructed optical access from all four sides to allow multi-angle excitation and emission detection. Traditional cuvettes with caps or limited optical windows obstruct light paths and reduce signal fidelity. Additionally, the need to gently load fragile single-cell suspensions without disturbing the sample makes conventional vertical loading impractical.

المزايا الرئيسية

محلول توكارتز

A German university lab conducting single-cell calcium imaging reported 22% signal loss due to sidewall refraction in standard 2-window cuvettes. After switching to TOQUARTZ®’s 4-sided transparent, open-top slanted cuvettes, signal-to-noise ratio improved by 31%, and cell viability during loading increased from 87% to 96%, enabling more accurate kinetic tracking of intracellular events.

Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge in Automated Liquid Handling Systems for High-Throughput Screening

In pharmaceutical and biotech labs, automated pipetting robots are used for high-throughput fluorescence assays. These systems require cuvettes that can be accessed from the top without obstruction and allow precise, bubble-free sample dispensing. Standard capped or narrow-neck cuvettes often cause pipette tip collisions or bubble entrapment, leading to failed assays and wasted reagents.

المزايا الرئيسية

محلول توكارتز

A US-based biotech CRO using Tecan EVO robots faced a 14% pipetting failure rate due to tip collisions with capped cuvettes. After adopting TOQUARTZ® open-top slanted cuvettes, failure rates dropped to 1.8%, and assay throughput increased by 19%, saving over $3,800/month in reagent waste and reruns.

Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge in Photobleaching Kinetics and Time-Resolved Fluorescence Decay Studies

Time-resolved fluorescence and photobleaching studies require precise control of excitation light exposure and rapid sample replacement. Researchers often need to quickly inject or replace samples between runs without disturbing the optical alignment. Cuvettes with caps or narrow openings slow down this process and introduce alignment errors. Additionally, any internal reflection from non-polished surfaces can distort decay curves.

المزايا الرئيسية

محلول توكارتز

A photophysics lab in Kyoto University reported 17% curve distortion due to internal reflections in standard 2-polish cuvettes. Switching to TOQUARTZ® 4-polish, open-top slanted cuvettes reduced distortion to under 3%, and sample exchange time dropped from 12s to 6.8s, enabling higher temporal resolution in photobleaching kinetics.

TOQUARTZ® Customization Options for Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge

TOQUARTZ® offers specialized customization services to meet your exact experimental requirements and instrument specifications.

Custom Dimensional Modifications

Material and Surface Options

عملية التخصيص

Usage Guide of Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge

Proper handling and maintenance of your quartz micro fluorescence cuvette will ensure optimal performance and extend its service life. Follow these guidelines for best results in your laboratory applications.

Sample Loading Procedure

احتياطات مهمة

التنظيف والصيانة

Need Technical Consultation for Your Quartz Micro Fluorescence Cuvette Requirements?

Our engineers provide free project consultation to help you select the right specifications for your application.
With experience serving research institutions worldwide, we can recommend the optimal solution for your specific needs.

لماذا الشراكة مع TOQUARTZ

ميزة المصنع المباشر

وبصفتنا شركة تصنيع مباشرة، يمكننا الاستغناء عن الروابط الوسيطة العديدة.

الخبرة الهندسية

يقوم الفريق التقني بتوجيه العملاء بدءاً من اختيار المواد إلى تحسين التصميم، وترجمة المواصفات إلى مخرجات.

التصنيع المرن

التعامل مع الطلبيات القياسية والمخصصة من خلال الخبرة في مجال الدُفعات الصغيرة والصرامة في وضع النماذج الأولية للوفاء بالمواعيد النهائية العاجلة.

الجودة
التأمين

التحقق من الصحة قبل الشحن في 3 خطوات:
1. دقة الأبعاد,
2. نقاء المادة,
3 - عتبات الأداء

سلسلة التوريد العالمية

خدمات لوجستية عالمية موثوقة إلى المراكز الصناعية (أولوية DE/US/JP/KR) مع مراحل إنجاز يمكن تتبعها.

المنتجات المستعادة

تقدم TOQUARTZ، بصفتها شركة تصنيع متخصصة تتمتع بقدرات المصنع المباشرة، حلول الكوارتز القياسية والمخصصة مع الدعم الهندسي طوال عملية تحديد المواصفات والتنفيذ.

الأسئلة الشائعة

Q: What are the advantages of four-sided optical transparency in the Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge?

A: The four-sided optical transparency allows multi-angle excitation and emission detection, which is essential for single-cell imaging, confocal microscopy, and time-resolved fluorescence studies requiring full-spectrum access.

A: For short to mid-duration assays, evaporation is minimal due to the small surface area. For longer runs, we recommend using a compatible sealing film or placing the cuvette in a humidity-controlled chamber.

A: The slanted edge guides the pipette tip naturally into the chamber, reducing the risk of tip misalignment and minimizing bubble formation during sample loading, especially in automated systems.

A: While open-top designs are more exposed, proper lab protocols (e.g., using filtered pipette tips and clean benches) effectively mitigate contamination risks. The benefit is faster access and easier cleaning.

A: Yes, the open-top design allows sub-5-second sample replacement, making it ideal for kinetic fluorescence assays and photobleaching studies where timing is critical.

اتصل بفريقنا الهندسي للحصول على الاستشارات الفنية والتسعير. سنساعدك في اختيار المواصفات المثلى لمتطلبات تطبيقك.

arالعربية
انتقل إلى الأعلى

احصل على عرض أسعار سريع الآن

أخبرنا بما تحتاج إليه - احصل على أسعار مصممة خصيصاً لك ومهلة زمنية محددة خلال 6 ساعات.

* تحقق من البريد الإلكتروني بعد الإرسال. لم يتم استلامها؟ تحقق من العنوان.