Quartz Micro Cuvette with Black Walls and Black Caps for Laboratory Spectroscopy -TOQUARTZ®

TOQUARTZ® High-purity optical quartz micro cuvette (≥99.98% SiO₂) with black walls for ultra-precise spectrophotometric and fluorescence analysis. Designed for minimal sample volumes (50μl-300μl) with excellent UV-Vis transmission range (200nm-2500nm). Black walls minimize stray light for enhanced sensitivity in fluorescence detection.
لا يوجد موك
تصميم مخصص
المصنع مباشرة
الدعم الفني

Features of Quartz Micro Cuvette with Black Walls and Black Caps

TOQUARTZ® micro cuvettes are engineered specifically for scientific applications requiring minimal sample volumes and high optical performance. Our black wall design provides significant advantages for fluorescence and sensitive spectroscopic measurements.

Micro Volume Capability

Designed for precious samples with minimal volume requirements, available in 50μl, 100μl, 200μl, and 300μl capacities.

مقاومة المواد الكيميائية

Excellent resistance to acids, bases, and organic solvents, making these cuvettes suitable for a wide range of chemical analyses.

الأداء البصري

High-purity quartz (≥99.98% SiO₂, max. up to 99.995%) with excellent transmission range from 200nm to 2500nm, ideal for UV-Vis and fluorescence applications.

Cross-Talk Minimizing Quartz Micro Cuvette with Black Walls and Black Caps
TOQUARTZ® Quartz Micro Cuvette with Black Walls and Black Caps

Technical Specifications & Dimensions of Quartz Micro Cuvette with Black Walls and Black Caps

TOQUARTZ® micro cuvettes with black walls are manufactured to precise specifications to ensure consistent performance across a wide range of spectroscopic applications.

المواصفات الفنية

الخصائص الفيزيائية

المعلمةالمواصفات
الموادكوارتز عالي النقاء (≥99.98% SiO2)
تشطيب السطحOptical polishing on window surfaces
المعالجة الجداريةطلاء أسود لعزل الضوء

الخواص الكيميائية

المعلمةالمواصفات
مقاومة المواد الكيميائيةExcellent to most acids, bases, and solvents
نطاق استقرار الأس الهيدروجيني1-14
توافق المذيباتمتوافق مع معظم المذيبات العضوية
الكارهة للماءمعتدل (زاوية التلامس ~ 30 درجة)

الخصائص البصرية

المعلمةالمواصفات
نطاق الإرسال200-2500 نانومتر
Absorbance Accuracy±0.005A
Window Flatness≤λ/4
تقليل الضوء الشارد>99% (black walls)

جدول المقاسات

50μl Quartz Micro Cuvette with Black Walls and Black Cap
الطرازالوصفالطول الموجيالمسار
الطول
الحجمالاستقرار الحراريبُعد المخطط التفصيلي
AT-BSM-402850μl Quartz Micro Cuvette with Black Walls and Black Cap200 نانومتر - 2500 نانومتر10 مم50 ميكرولتر100℃12.5 × 12.5 × 12.5 × 45 مم
50μl Quartz Micro Cuvette with Black Walls and Black Lid
الطرازالوصفالطول الموجيالمسار
الطول
الحجمالاستقرار الحراريبُعد المخطط التفصيلي
AT-BSM-402250μl Quartz Micro Cuvette with Black Walls and Black Lid200 نانومتر - 2500 نانومتر10 مم50 ميكرولتر100℃12.5 × 12.5 × 12.5 × 45 مم
100μl Quartz Micro Cuvette with Black Walls and Black Cap
الطرازالوصفالطول الموجيالمسار
الطول
الحجمالاستقرار الحراريبُعد المخطط التفصيلي
AT-BSM-4023100μl Quartz Micro Cuvette with Black Walls and Black Cap200 نانومتر - 2500 نانومتر10 مم100 ميكرولتر100℃12.5 × 12.5 × 12.5 × 45 مم
200μl Quartz Micro Cuvette with Black Walls and Black Cap
الطرازالوصفالطول الموجيالمسار
الطول
الحجمالاستقرار الحراريبُعد المخطط التفصيلي
AT-BSM-4025200 μlQuartz Micro Cuvette with Black Walls and Black Cap200 نانومتر - 2500 نانومتر10 مم200 ميكرولتر100℃12.5 × 12.5 × 12.5 × 45 مم
300μl Quartz Micro Cuvette with Black Walls and Black Cap
الطرازالوصفالطول الموجيالمسار
الطول
الحجمالاستقرار الحراريبُعد المخطط التفصيلي
AT-BSM-4024300 μlQuartz Micro Cuvette with Black Walls and Black Cap200 نانومتر - 2500 نانومتر10 مم300 ميكرولتر100℃12.5 × 12.5 × 12.5 × 45 مم
ملاحظة: نقدم مواصفات مخصصة لتلبية متطلباتك الخاصة. اتصل بفريقنا الهندسي للاستشارة.

TOQUARTZ® Solving Laboratory Challenges with Black Wall Quartz Micro Cuvettes

Quartz Micro Cuvette with Black Walls for DNA/RNA Quantification

Life science laboratories frequently work with precious nucleic acid samples where volume conservation is critical. Traditional cuvettes require substantial sample volumes (1-3ml), leading to waste of valuable material. Additionally, fluorescence-based quantification methods are hampered by stray light and background interference.

المزايا الرئيسية

محلول توكارتز

A molecular biology lab in Heidelberg, Germany, reported inconsistent DNA quantification using standard 1ml cuvettes due to sample scarcity and high background noise. After switching to TOQUARTZ® 50μl black wall micro cuvettes, they achieved a 92% reduction in sample usage and a 1.8× improvement in fluorescence signal clarity. This enabled accurate quantification of DNA at concentrations as low as 0.3ng/μl, critical for their low-yield extraction workflows.

Quartz Micro Cuvette with Black Walls for Trace Analysis in Environmental Samples

Environmental testing laboratories must detect trace contaminants in water and soil extracts with high sensitivity. Conventional spectrophotometric methods struggle with sample-limited analyses and suffer from optical interference when measuring fluorescent compounds at parts-per-billion levels.

المزايا الرئيسية

محلول توكارتز

An environmental testing lab in Ontario, Canada, faced challenges detecting trace polycyclic aromatic hydrocarbons (PAHs) in river water due to high background fluorescence. Using TOQUARTZ® 100μl black wall cuvettes, they reduced optical noise by 21% and achieved consistent detection of benzo pyrene at 4.7ppb. This allowed them to meet regulatory reporting thresholds without increasing sample volume or processing time.

Quartz Micro Cuvette with Black Walls for Pharmaceutical Formulation Analysis

Pharmaceutical research requires precise analysis of API (Active Pharmaceutical Ingredient) concentrations in various formulations. Limited sample availability during early-stage development and interference from excipients create significant analytical challenges. Accurate spectroscopic measurements are essential for quality control and formulation optimization.

المزايا الرئيسية

محلول توكارتز

A pharmaceutical R&D center in Osaka, Japan, struggled with accurate UV absorbance readings of early-stage API formulations due to excipient interference and limited sample availability. After adopting TOQUARTZ® 100μl black wall cuvettes, they reduced API usage per test from 500μl to 100μl and improved measurement repeatability by 93%. This enabled faster iteration of formulation batches while maintaining QC compliance.

TOQUARTZ® Customization Options for Quartz Micro Cuvette with Black Walls and Black Caps

TOQUARTZ® offers specialized customization options for our black wall quartz micro cuvettes to meet your specific research or analytical requirements. Our engineering team works directly with you to design and manufacture the exact cuvette specifications you need.

الأبعاد المخصصة

ميزات خاصة

معالجات السطح

Usage Guide of Quartz Micro Cuvette with Black Walls and Black Caps

Proper handling and maintenance of quartz micro cuvettes with black walls ensures optimal performance and extends their service life. Follow these guidelines to maximize measurement accuracy and product longevity.

Proper Handling Procedures

تعليمات التنظيف

أفضل ممارسات القياس

توصيات التخزين

Need Technical Assistance with Quartz Micro Cuvettes?

Our engineers provide free project consultation to help you select the right black wall cuvette for your application.

لماذا الشراكة مع TOQUARTZ

ميزة المصنع المباشر

وبصفتنا شركة تصنيع مباشرة، يمكننا الاستغناء عن الروابط الوسيطة العديدة.

الخبرة الهندسية

يقوم الفريق التقني بتوجيه العملاء بدءاً من اختيار المواد إلى تحسين التصميم، وترجمة المواصفات إلى مخرجات.

التصنيع المرن

التعامل مع الطلبيات القياسية والمخصصة من خلال الخبرة في مجال الدُفعات الصغيرة والصرامة في وضع النماذج الأولية للوفاء بالمواعيد النهائية العاجلة.

الجودة
التأمين

التحقق من الصحة قبل الشحن في 3 خطوات:
1. دقة الأبعاد,
2. نقاء المادة,
3 - عتبات الأداء

سلسلة التوريد العالمية

خدمات لوجستية عالمية موثوقة إلى المراكز الصناعية (أولوية DE/US/JP/KR) مع مراحل إنجاز يمكن تتبعها.

المنتجات المستعادة

تقدم TOQUARTZ، بصفتها شركة تصنيع متخصصة تتمتع بقدرات المصنع المباشرة، حلول الكوارتز القياسية والمخصصة مع الدعم الهندسي طوال عملية تحديد المواصفات والتنفيذ.

الأسئلة الشائعة

Q: Will the black walls of the Quartz Micro Cuvette with Black Walls and Black Caps affect UV-Vis transmission?

A: No, the optical windows remain transparent quartz; only the side walls are black-coated, ensuring full UV-Vis transmission (200–2500nm) through the measurement path.

A: The black coating is chemically bonded and resistant to most solvents, but abrasive cleaning or exposure to HF can damage it. Use non-abrasive cleaning methods only.

A: The black cap prevents ambient light from entering the cuvette from the top, reducing background noise and improving signal-to-noise ratio in fluorescence detection.

A: Yes, they follow the standard 12.5mm × 12.5mm × 45mm external dimensions and fit most commercial instruments with 10mm path length holders.

A: Variations may result from improper orientation, cap misalignment, or inconsistent sample volume. Always align the optical windows correctly and fill to the recommended volume.

اتصل بفريقنا الهندسي للحصول على الاستشارات الفنية والتسعير. سنساعدك في اختيار المواصفات المثلى لمتطلبات تطبيقك.

arالعربية
انتقل إلى الأعلى

احصل على عرض أسعار سريع الآن

أخبرنا بما تحتاج إليه - احصل على أسعار مصممة خصيصاً لك ومهلة زمنية محددة خلال 6 ساعات.