- Início
- /
- Tipos
- /
- Cubeta de quartzo
- /
- Micro cuvete de quartzo
- /
- Bubble-Minimizing Quartz Micro Fluorescence...
Bubble-Minimizing Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge -TOQUARTZ®
Features of Quartz Micro Fluorescence Cuvette with
Open Top and Slanted Edge
TOQUARTZ® high-purity quartz micro fluorescence cuvettes are designed to deliver exceptional performance for precision spectroscopy applications. Each cuvette is manufactured to exacting standards to ensure consistent results across your research and testing protocols.
Precision Slanted Edge Design
ngineered for easy sample loading and reduced bubble formation, minimizing experimental errors during critical research.
Desempenho óptico
Transmission range of 200-2500nm with no absorption peaks, making it ideal for UV-VIS-NIR spectroscopy applications.
Resistência química
Maintains stability against acids, bases, and corrosive solutions, ensuring longevity even in harsh chemical environments.
Estabilidade térmica
Withstands temperatures up to 100°C, suitable for various thermal applications and experimental conditions.

- SiO2 Pureza ≥99,98%, até 99,995%
- Resistência química a reagentes agressivos
- Serviços de personalização disponíveis
Technical Specifications & Dimensions of Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge
Especificações técnicas
Parâmetro | Especificação |
Material | High-purity quartz (≥99.98% SiO2, max. up to 99.995%) |
Resistência à tração | 50 MPa |
Densidade | 2,2 g/cm³ |
Coeficiente de expansão térmica | 5.5×10-7/℃ |
Acabamento da superfície | Optical polish on all four sides |
Resistência a ácidos | Excelente (exceto HF) |
Resistência a álcalis | Bom até pH 12 |
Compatibilidade com solventes | Compatível com a maioria dos solventes orgânicos |
Biocompatibilidade | Inerte, não reativo com amostras biológicas |
Faixa de transmissão | 200-2500nm |
Corte de UV | <190nm |
Índice de refração | 1,46 a 589,3 nm |
Tabela de tamanhos

Modelo | Descrição | Comprimento de onda | Caminho Comprimento | Volume | Estabilidade térmica | Dimensão do contorno |
AT-BSM-4020 | 140μl Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge | 200nm-2500nm | 1mm/4mm | 140μl | 100℃ | 12,5×12,5x45 mm |
TOQUARTZ® Solving Laboratory Challenges with Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge
Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge in Single-Cell Fluorescence Imaging Chambers
Principais vantagens
-
Multi-angle excitation enabled by 4-sided optical access
Allows 360° fluorescence excitation and emission collection, improving signal acquisition by up to 28% in confocal setups. -
Slanted edge supports gentle cell suspension loading
Reduces shear stress during pipetting, preserving >95% cell viability in microfluidic chambers. -
No-cap design eliminates vertical optical obstruction
Ensures uninterrupted Z-axis imaging in upright and inverted fluorescence microscopes.
Solução TOQUARTZ
A German university lab conducting single-cell calcium imaging reported 22% signal loss due to sidewall refraction in standard 2-window cuvettes. After switching to TOQUARTZ®’s 4-sided transparent, open-top slanted cuvettes, signal-to-noise ratio improved by 31%, and cell viability during loading increased from 87% to 96%, enabling more accurate kinetic tracking of intracellular events.
Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge in Automated Liquid Handling Systems for High-Throughput Screening
Principais vantagens
-
Slanted edge aligns pipette tips automatically
Reduces robotic tip misalignment errors by 85% in automated dispensing systems. -
Open-top design prevents pipette head collisions
Eliminates vertical clearance issues in 96-well robotic platforms with <15mm Z-axis tolerance. -
Bubble-free loading improves assay reproducibility
Decreases fluorescence signal variability by 22% in enzyme inhibition assays.
Solução TOQUARTZ
A US-based biotech CRO using Tecan EVO robots faced a 14% pipetting failure rate due to tip collisions with capped cuvettes. After adopting TOQUARTZ® open-top slanted cuvettes, failure rates dropped to 1.8%, and assay throughput increased by 19%, saving over $3,800/month in reagent waste and reruns.
Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge in Photobleaching Kinetics and Time-Resolved Fluorescence Decay Studies
Principais vantagens
-
Open-top allows sub-5s sample exchange between runs
Reduces inter-run delay by 42% in time-sensitive decay experiments. -
Slanted edge enables non-disruptive injection
Minimizes optical path disturbance, maintaining <2% baseline drift across runs. -
4-side polish eliminates internal reflection artifacts
Improves decay curve linearity by 18% in picosecond-resolved fluorescence studies.
Solução TOQUARTZ
A photophysics lab in Kyoto University reported 17% curve distortion due to internal reflections in standard 2-polish cuvettes. Switching to TOQUARTZ® 4-polish, open-top slanted cuvettes reduced distortion to under 3%, and sample exchange time dropped from 12s to 6.8s, enabling higher temporal resolution in photobleaching kinetics.
TOQUARTZ® Customization Options for Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge
Custom Dimensional Modifications
- Customized path length options
- Sample volume variations
- Custom slanted edge angles for specific loading requirements
- Modified height and width dimensions for instrument compatibility
Material and Surface Options
- Ultra-high purity quartz (≥99.98% SiO₂, max. up to 99.995%) for demanding applications
- Specialized optical window selection
- Opções de tratamento de superfície
- Anti-reflection coatings for specific wavelength ranges
Processo de personalização
- Initial consultation to understand your application requirements
- Technical drawing review and feasibility assessment
- Prototype development and validation (for new designs)
- Produção de pequenos lotes para testes
- Produção completa com controle de qualidade abrangente
Usage Guide of Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge
Sample Loading Procedure
- Clean and dry the cuvette thoroughly before use.
- Using a micropipette, slowly dispense sample onto the slanted edge.
- Allow liquid to flow down gradually to avoid bubble formation.
- Verify that the sample volume completely fills the measurement zone.
- Place carefully in instrument holder, aligning with light path.
Precauções importantes
- Avoid thermal shock – allow cuvette to equilibrate to room temperature before use.
- Do not exceed 100°C thermal limit to prevent damage.
- Never use abrasive materials for cleaning.
- Avoid hydrofluoric acid (HF) which can etch quartz surfaces.
- Inspect for chips or cracks before each use; damaged cuvettes may lead to inaccurate results.
Limpeza e manutenção
- Daily Cleaning: Rinse with deionized water followed by analytical grade methanol or ethanol.
- For Protein Residues: Use 1% laboratory detergent solution, then rinse thoroughly.
- For Stubborn Contaminants: Soak in 10% nitric acid solution for 30 minutes (avoid HF acid).
- Secagem: Use filtered compressed air or nitrogen gas; avoid wiping optical surfaces.
- Armazenamento: Store in original packaging or dust-free container.
- Manuseio: Always handle by edges, never touch optical surfaces.
Need Technical Consultation for Your Quartz Micro Fluorescence Cuvette Requirements?
With experience serving research institutions worldwide, we can recommend the optimal solution for your specific needs.
Por que fazer parceria com a TOQUARTZ?
Vantagem da fábrica direta
Como fabricante direto, podemos eliminar os inúmeros elos intermediários.
Especialização em engenharia
A equipe técnica orienta os clientes desde a seleção do material até a otimização do projeto, traduzindo as especificações em produtos.
Fabricação flexível
Atendimento de pedidos padrão e personalizados por meio de experiência em pequenos lotes e rigor na criação de protótipos para cumprir prazos urgentes.
Qualidade
Garantia
Validação em três etapas antes da remessa:
1. precisão dimensional,
2. pureza do material,
3. limites de desempenho
Cadeia de suprimentos global
Logística global confiável para centros industriais (prioridade DE/US/JP/KR) com marcos rastreáveis.
Produtos liberados
Como um fabricante especializado com recursos de fábrica direta, a TOQUARTZ fornece soluções de quartzo padrão e personalizadas com suporte de engenharia durante todo o processo de especificação e implementação.
PERGUNTAS FREQUENTES
Q: What are the advantages of four-sided optical transparency in the Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge?
A: The four-sided optical transparency allows multi-angle excitation and emission detection, which is essential for single-cell imaging, confocal microscopy, and time-resolved fluorescence studies requiring full-spectrum access.
Q: Will the open-top design of the Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge cause sample evaporation during long experiments?
A: For short to mid-duration assays, evaporation is minimal due to the small surface area. For longer runs, we recommend using a compatible sealing film or placing the cuvette in a humidity-controlled chamber.
Q: How does the slanted edge of the Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge improve pipetting accuracy?
A: The slanted edge guides the pipette tip naturally into the chamber, reducing the risk of tip misalignment and minimizing bubble formation during sample loading, especially in automated systems.
Q: How does the open-top design of the Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge affect contamination risk?
A: While open-top designs are more exposed, proper lab protocols (e.g., using filtered pipette tips and clean benches) effectively mitigate contamination risks. The benefit is faster access and easier cleaning.
Q: Can the Quartz Micro Fluorescence Cuvette with Open Top and Slanted Edge be used for kinetic assays requiring rapid sample exchange?
A: Yes, the open-top design allows sub-5-second sample replacement, making it ideal for kinetic fluorescence assays and photobleaching studies where timing is critical.
Entre em contato com nossa equipe de engenharia para obter consultoria técnica e preços. Nós o ajudaremos a selecionar as especificações ideais para os requisitos de sua aplicação.