Quartz Micro Cuvette with Black Walls and Black Caps for Laboratory Spectroscopy -TOQUARTZ®

TOQUARTZ® High-purity optical quartz micro cuvette (≥99.98% SiO₂) with black walls for ultra-precise spectrophotometric and fluorescence analysis. Designed for minimal sample volumes (50μl-300μl) with excellent UV-Vis transmission range (200nm-2500nm). Black walls minimize stray light for enhanced sensitivity in fluorescence detection.
Sem MOQ
Design personalizado
Direto da fábrica
Suporte técnico

Features of Quartz Micro Cuvette with Black Walls and Black Caps

TOQUARTZ® micro cuvettes are engineered specifically for scientific applications requiring minimal sample volumes and high optical performance. Our black wall design provides significant advantages for fluorescence and sensitive spectroscopic measurements.

Micro Volume Capability

Designed for precious samples with minimal volume requirements, available in 50μl, 100μl, 200μl, and 300μl capacities.

Resistência química

Excellent resistance to acids, bases, and organic solvents, making these cuvettes suitable for a wide range of chemical analyses.

Desempenho óptico

High-purity quartz (≥99.98% SiO₂, max. up to 99.995%) with excellent transmission range from 200nm to 2500nm, ideal for UV-Vis and fluorescence applications.

Micro cuvete de quartzo com paredes e tampas pretas que minimizam o contato cruzado
TOQUARTZ® Quartz Micro Cuvette with Black Walls and Black Caps

Technical Specifications & Dimensions of Quartz Micro Cuvette with Black Walls and Black Caps

TOQUARTZ® micro cuvettes with black walls are manufactured to precise specifications to ensure consistent performance across a wide range of spectroscopic applications.

Especificações técnicas

Propriedades físicas

ParâmetroEspecificação
MaterialQuartzo de alta pureza (≥99,98% SiO2)
Acabamento da superfícieOptical polishing on window surfaces
Tratamento de paredesRevestimento preto para isolamento de luz

Propriedades químicas

ParâmetroEspecificação
Resistência químicaExcellent to most acids, bases, and solvents
Faixa de estabilidade de pH1-14
Compatibilidade com solventesCompatível com a maioria dos solventes orgânicos
HidrofobicidadeModerate (contact angle ~30°)

Propriedades ópticas

ParâmetroEspecificação
Faixa de transmissão200-2500nm
Absorbance Accuracy±0.005A
Window Flatness≤λ/4
Redução de luz difusa>99% (black walls)

Tabela de tamanhos

50μl Quartz Micro Cuvette with Black Walls and Black Cap
ModeloDescriçãoComprimento de ondaCaminho
Comprimento
VolumeEstabilidade térmicaDimensão do contorno
AT-BSM-402850μl Quartz Micro Cuvette with Black Walls and Black Cap200nm-2500nm10 mm50μl100℃12,5×12,5x45 mm
50μl Quartz Micro Cuvette with Black Walls and Black Lid
ModeloDescriçãoComprimento de ondaCaminho
Comprimento
VolumeEstabilidade térmicaDimensão do contorno
AT-BSM-402250μl Quartz Micro Cuvette with Black Walls and Black Lid200nm-2500nm10 mm50μl100℃12,5×12,5x45 mm
100μl Quartz Micro Cuvette with Black Walls and Black Cap
ModeloDescriçãoComprimento de ondaCaminho
Comprimento
VolumeEstabilidade térmicaDimensão do contorno
AT-BSM-4023100μl Quartz Micro Cuvette with Black Walls and Black Cap200nm-2500nm10 mm100μl100℃12,5×12,5x45 mm
200μl Quartz Micro Cuvette with Black Walls and Black Cap
ModeloDescriçãoComprimento de ondaCaminho
Comprimento
VolumeEstabilidade térmicaDimensão do contorno
AT-BSM-4025200 μlQuartz Micro Cuvette with Black Walls and Black Cap200nm-2500nm10 mm200μl100℃12,5×12,5x45 mm
300μl Quartz Micro Cuvette with Black Walls and Black Cap
ModeloDescriçãoComprimento de ondaCaminho
Comprimento
VolumeEstabilidade térmicaDimensão do contorno
AT-BSM-4024300 μlQuartz Micro Cuvette with Black Walls and Black Cap200nm-2500nm10 mm300μl100℃12,5×12,5x45 mm
Observação: Oferecemos especificações personalizadas para atender às suas necessidades específicas. Entre em contato com a nossa equipe de engenharia para consulta.

TOQUARTZ® Solving Laboratory Challenges with Black Wall Quartz Micro Cuvettes

Quartz Micro Cuvette with Black Walls for DNA/RNA Quantification

Life science laboratories frequently work with precious nucleic acid samples where volume conservation is critical. Traditional cuvettes require substantial sample volumes (1-3ml), leading to waste of valuable material. Additionally, fluorescence-based quantification methods are hampered by stray light and background interference.

Principais vantagens

Solução TOQUARTZ

A molecular biology lab in Heidelberg, Germany, reported inconsistent DNA quantification using standard 1ml cuvettes due to sample scarcity and high background noise. After switching to TOQUARTZ® 50μl black wall micro cuvettes, they achieved a 92% reduction in sample usage and a 1.8× improvement in fluorescence signal clarity. This enabled accurate quantification of DNA at concentrations as low as 0.3ng/μl, critical for their low-yield extraction workflows.

Quartz Micro Cuvette with Black Walls for Trace Analysis in Environmental Samples

Environmental testing laboratories must detect trace contaminants in water and soil extracts with high sensitivity. Conventional spectrophotometric methods struggle with sample-limited analyses and suffer from optical interference when measuring fluorescent compounds at parts-per-billion levels.

Principais vantagens

Solução TOQUARTZ

An environmental testing lab in Ontario, Canada, faced challenges detecting trace polycyclic aromatic hydrocarbons (PAHs) in river water due to high background fluorescence. Using TOQUARTZ® 100μl black wall cuvettes, they reduced optical noise by 21% and achieved consistent detection of benzo pyrene at 4.7ppb. This allowed them to meet regulatory reporting thresholds without increasing sample volume or processing time.

Quartz Micro Cuvette with Black Walls for Pharmaceutical Formulation Analysis

Pharmaceutical research requires precise analysis of API (Active Pharmaceutical Ingredient) concentrations in various formulations. Limited sample availability during early-stage development and interference from excipients create significant analytical challenges. Accurate spectroscopic measurements are essential for quality control and formulation optimization.

Principais vantagens

Solução TOQUARTZ

A pharmaceutical R&D center in Osaka, Japan, struggled with accurate UV absorbance readings of early-stage API formulations due to excipient interference and limited sample availability. After adopting TOQUARTZ® 100μl black wall cuvettes, they reduced API usage per test from 500μl to 100μl and improved measurement repeatability by 93%. This enabled faster iteration of formulation batches while maintaining QC compliance.

TOQUARTZ® Customization Options for Quartz Micro Cuvette with Black Walls and Black Caps

TOQUARTZ® offers specialized customization options for our black wall quartz micro cuvettes to meet your specific research or analytical requirements. Our engineering team works directly with you to design and manufacture the exact cuvette specifications you need.

Dimensões personalizadas

Recursos especiais

Tratamentos de superfície

Usage Guide of Quartz Micro Cuvette with Black Walls and Black Caps

Proper handling and maintenance of quartz micro cuvettes with black walls ensures optimal performance and extends their service life. Follow these guidelines to maximize measurement accuracy and product longevity.

Proper Handling Procedures

Instruções de limpeza

Práticas recomendadas de medição

Recomendações de armazenamento

Need Technical Assistance with Quartz Micro Cuvettes?

Our engineers provide free project consultation to help you select the right black wall cuvette for your application.

Por que fazer parceria com a TOQUARTZ?

Vantagem da fábrica direta

Como fabricante direto, podemos eliminar os inúmeros elos intermediários.

Especialização em engenharia

A equipe técnica orienta os clientes desde a seleção do material até a otimização do projeto, traduzindo as especificações em produtos.

Fabricação flexível

Atendimento de pedidos padrão e personalizados por meio de experiência em pequenos lotes e rigor na criação de protótipos para cumprir prazos urgentes.

Qualidade
Garantia

Validação em três etapas antes da remessa:
1. precisão dimensional,
2. pureza do material,
3. limites de desempenho

Cadeia de suprimentos global

Logística global confiável para centros industriais (prioridade DE/US/JP/KR) com marcos rastreáveis.

PERGUNTAS FREQUENTES

Q: Will the black walls of the Quartz Micro Cuvette with Black Walls and Black Caps affect UV-Vis transmission?

A: No, the optical windows remain transparent quartz; only the side walls are black-coated, ensuring full UV-Vis transmission (200–2500nm) through the measurement path.

A: The black coating is chemically bonded and resistant to most solvents, but abrasive cleaning or exposure to HF can damage it. Use non-abrasive cleaning methods only.

A: The black cap prevents ambient light from entering the cuvette from the top, reducing background noise and improving signal-to-noise ratio in fluorescence detection.

A: Yes, they follow the standard 12.5mm × 12.5mm × 45mm external dimensions and fit most commercial instruments with 10mm path length holders.

A: Variations may result from improper orientation, cap misalignment, or inconsistent sample volume. Always align the optical windows correctly and fill to the recommended volume.

Entre em contato com nossa equipe de engenharia para obter consultoria técnica e preços. Nós o ajudaremos a selecionar as especificações ideais para os requisitos de sua aplicação.

pt_BRPortuguês do Brasil
Role até o topo

Obtenha uma cotação rápida agora

Diga-nos o que você precisa - Receba preços personalizados e prazo de entrega em 6 horas.

* Verifique o e-mail após o envio. Não foi recebido? Verifique o endereço.