{"id":11029,"date":"2026-01-11T02:00:43","date_gmt":"2026-01-10T18:00:43","guid":{"rendered":"https:\/\/toquartz.com\/?p=11029"},"modified":"2025-10-21T17:17:44","modified_gmt":"2025-10-21T09:17:44","slug":"laser-window-damage-threshold-specifications-guide","status":"publish","type":"post","link":"https:\/\/toquartz.com\/fr\/laser-window-damage-threshold-specifications-guide\/","title":{"rendered":"Quel est le seuil d'endommagement laser n\u00e9cessaire aux disques de quartz pour les \u00e9quipements laser de haute puissance ?"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"400\" src=\"https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/67fc7862018848b9adcd5eb0495138da.jpg\" alt=\"Quel est le seuil d&#039;endommagement laser n\u00e9cessaire aux disques de quartz pour les \u00e9quipements laser de haute puissance ?\" class=\"wp-image-11026\" srcset=\"https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/67fc7862018848b9adcd5eb0495138da.jpg 800w, https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/67fc7862018848b9adcd5eb0495138da-300x150.jpg 300w, https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/67fc7862018848b9adcd5eb0495138da-768x384.jpg 768w, https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/67fc7862018848b9adcd5eb0495138da-18x9.jpg 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\"><\/figcaption><\/figure>\n\n\n<p>Les disques de quartz utilis\u00e9s dans les \u00e9quipements laser de haute puissance doivent r\u00e9pondre \u00e0 des exigences strictes en mati\u00e8re de seuil d'endommagement des lasers. Pour les syst\u00e8mes de 1 \u00e0 3 kW, le seuil recommand\u00e9 est d'au moins 10 J\/cm\u00b2, tandis que les niveaux de puissance plus \u00e9lev\u00e9s exigent une durabilit\u00e9 encore plus grande. Le choix de disques de quartz \u00e0 seuil d'endommagement laser ad\u00e9quat pour les \u00e9quipements de haute puissance garantit un fonctionnement fiable et r\u00e9duit les temps d'arr\u00eat co\u00fbteux dans les environnements industriels.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Principaux enseignements<\/h2>\n\n\n<ul class=\"wp-block-list\">\n<li><p>Pour les syst\u00e8mes de 1 \u00e0 3 kW, choisir des disques de quartz ayant un seuil de dommage laser d'au moins 10 J\/cm\u00b2 afin d'assurer un fonctionnement fiable.<\/p><\/li><li><p>Utilisez une marge de s\u00e9curit\u00e9 de 2,5 \u00e0 3 fois sup\u00e9rieure \u00e0 la densit\u00e9 de puissance calcul\u00e9e pour vous prot\u00e9ger contre les dommages inattendus et prolonger la dur\u00e9e de vie des disques de quartz.<\/p><\/li><li><p>Il faut savoir que les impulsions laser plus courtes n\u00e9cessitent des valeurs LIDT plus \u00e9lev\u00e9es en raison de l'augmentation de l'intensit\u00e9 maximale, ce qui augmente le risque de dommages.<\/p><\/li><li><p>Choisissez du quartz de haute puret\u00e9 (\u2265 99,99% SiO\u2082) pour minimiser l'absorption d'impuret\u00e9s et am\u00e9liorer la r\u00e9sistance du disque aux dommages caus\u00e9s par le laser.<\/p><\/li><li><p>Mettre en \u0153uvre des essais S-on-1 pour valider le LIDT dans des conditions r\u00e9elles, en s'assurant que les disques de quartz peuvent r\u00e9sister \u00e0 des applications de haute puissance.<\/p><\/li>\n<\/ul>\n\n\n<h2 class=\"wp-block-heading\">Quelles sont les valeurs LIDT requises pour les disques de quartz pour diff\u00e9rents niveaux de puissance laser ?<\/h2>\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/ac30930a97c44be4a93128b97f88e44e.webp\" alt=\"Quelles sont les valeurs LIDT requises pour les disques de quartz pour diff\u00e9rents niveaux de puissance laser ?\" class=\"wp-image-11027\" srcset=\"https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/ac30930a97c44be4a93128b97f88e44e.webp 1200w, https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/ac30930a97c44be4a93128b97f88e44e-300x169.webp 300w, https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/ac30930a97c44be4a93128b97f88e44e-1024x576.webp 1024w, https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/ac30930a97c44be4a93128b97f88e44e-768x432.webp 768w, https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/ac30930a97c44be4a93128b97f88e44e-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\"><\/figcaption><\/figure>\n\n\n<p><a target=\"_blank\" rel=\"\" href=\"https:\/\/toquartz.com\/fr\/clear-quartz-glass-plate\/\">Disques en quartz<\/a> dans les optiques des lasers de haute puissance doivent r\u00e9pondre \u00e0 des exigences sp\u00e9cifiques afin d'\u00e9viter tout dommage pendant le fonctionnement. Le seuil d'endommagement induit par le laser d\u00e9pend de la puissance du laser, du profil du faisceau et de la dur\u00e9e de fonctionnement de l'\u00e9quipement. La compr\u00e9hension de ces facteurs aide les utilisateurs \u00e0 s\u00e9lectionner les disques de quartz ad\u00e9quats pour des performances fiables et s\u00fbres.<\/p>\n\n\n<h3 class=\"wp-block-heading\">M\u00e9thodes de calcul de la densit\u00e9 de puissance pour diff\u00e9rents profils de faisceaux<\/h3>\n\n\n<p>La densit\u00e9 de puissance du laser indique la quantit\u00e9 d'\u00e9nergie qui frappe un disque de quartz dans une zone donn\u00e9e. Le calcul varie en fonction de la forme du faisceau laser. Un faisceau gaussien concentre la majeure partie de sa puissance au centre, tandis qu'un faisceau \u00e0 sommet plat la r\u00e9partit uniform\u00e9ment.<\/p>\n\n\n<p>Les ing\u00e9nieurs calculent la densit\u00e9 de puissance de cr\u00eate d'un faisceau gaussien en divisant la puissance totale du laser par la surface d\u00e9finie par le diam\u00e8tre 1\/e\u00b2. Pour les faisceaux Flat Top, le calcul est plus simple car la puissance se r\u00e9partit uniform\u00e9ment, mais la densit\u00e9 de puissance de cr\u00eate est g\u00e9n\u00e9ralement deux fois plus \u00e9lev\u00e9e que celle d'un faisceau gaussien de m\u00eame diam\u00e8tre. Cette diff\u00e9rence signifie que les disques de quartz utilis\u00e9s dans les \u00e9quipements laser de haute puissance doivent avoir un seuil de dommage laser plus \u00e9lev\u00e9 lorsqu'ils sont utilis\u00e9s avec des faisceaux Flat Top, en particulier au m\u00eame niveau de puissance.<\/p>\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Points cl\u00e9s \u00e0 retenir :<\/strong><\/p><ul><li><p><strong>Faisceaux gaussiens :<\/strong> Densit\u00e9 de puissance de cr\u00eate au centre, calcul\u00e9e avec 1\/e\u00b2 du diam\u00e8tre.<\/p><\/li><li><p><strong>Poutres Flat Top :<\/strong> Puissance uniforme, densit\u00e9 de cr\u00eate environ 2 fois sup\u00e9rieure \u00e0 celle d'une gaussienne.<\/p><\/li><li><p><strong>Calcul correct :<\/strong> Veille \u00e0 ce que le seuil d'endommagement du disque de quartz induit par le laser corresponde aux conditions r\u00e9elles.<\/p><\/li><\/ul><\/blockquote>\n\n\n<p>Le choix de la bonne m\u00e9thode de calcul permet d'\u00e9viter les dommages inattendus et de prolonger la dur\u00e9e de vie du disque de quartz. Cette \u00e9tape est essentielle pour toutes les applications d'optique laser de haute puissance.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Exigences de la LIDT pour les lasers \u00e0 ondes puls\u00e9es et les lasers \u00e0 ondes continues<\/h3>\n\n\n<p>Les lasers puls\u00e9s et les lasers \u00e0 ondes continues (CW) posent des probl\u00e8mes diff\u00e9rents pour les disques de quartz. Les lasers puls\u00e9s fournissent de l'\u00e9nergie en courtes rafales, tandis que les lasers \u00e0 onde continue fournissent une sortie r\u00e9guli\u00e8re. Le seuil d'endommagement des disques de quartz induit par le laser varie en fonction du type de laser utilis\u00e9.<\/p>\n\n\n<p>Les dur\u00e9es d'impulsion plus courtes des lasers puls\u00e9s cr\u00e9ent des pics d'intensit\u00e9 plus \u00e9lev\u00e9s. Cela augmente le risque de dommages, m\u00eame si la puissance moyenne est la m\u00eame que celle d'un laser \u00e0 ondes entretenues. En revanche, les lasers \u00e0 ondes entretenues ont une puissance plus stable, de sorte que le seuil d'endommagement d\u00e9pend davantage de la quantit\u00e9 de chaleur que le disque de quartz peut supporter au fil du temps. Les disques de quartz utilis\u00e9s dans les \u00e9quipements laser de haute puissance doivent respecter des valeurs LIDT plus \u00e9lev\u00e9es pour les lasers puls\u00e9s, en particulier pour les puissances de cr\u00eate \u00e9lev\u00e9es.<\/p>\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"><col style=\"min-width: 25px;\"><col style=\"min-width: 25px;\"><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Type de laser<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Exigence de la LIDT<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Relation de cause \u00e0 effet<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Impulsion<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Plus \u00e9lev\u00e9<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Impulsions courtes = pic d'intensit\u00e9 plus \u00e9lev\u00e9 = risque de dommages plus important<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Onde continue<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Plus bas<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Puissance constante = accumulation de chaleur = risque de dommages thermiques<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n<p>Le choix du disque de quartz adapt\u00e9 \u00e0 chaque type de laser prot\u00e8ge contre les dommages soudains et \u00e0 long terme. Ce choix am\u00e9liore la fiabilit\u00e9 et r\u00e9duit les temps d'arr\u00eat co\u00fbteux.<\/p>\n\n\n<h3 class=\"wp-block-heading\">D\u00e9termination de la marge de s\u00e9curit\u00e9 en fonction de la dur\u00e9e d'exploitation<\/h3>\n\n\n<p>Les ing\u00e9nieurs utilisent des marges de s\u00e9curit\u00e9 pour s'assurer que les disques de quartz durent pendant un long fonctionnement du laser. Une marge de s\u00e9curit\u00e9 consiste \u00e0 choisir un disque dont le seuil d'endommagement du laser est plus \u00e9lev\u00e9 que la puissance maximale attendue. Cela permet d'\u00e9viter les dommages caus\u00e9s par de petits d\u00e9fauts ou des pics de puissance inattendus.<\/p>\n\n\n<p>Des imperfections mineures \u00e0 la surface du disque peuvent abaisser le seuil d'endommagement de plus de 40%. M\u00eame un seul d\u00e9faut \u00e0 forte absorption peut entra\u00eener une d\u00e9faillance pr\u00e9coce. La propret\u00e9 et la qualit\u00e9 de la surface sont essentielles pour les optiques laser de haute puissance, en particulier lorsque l'\u00e9quipement fonctionne pendant de nombreuses heures chaque jour.<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>R\u00e9sum\u00e9 des meilleures pratiques en mati\u00e8re de marges de s\u00e9curit\u00e9 :<\/strong><\/p><ul><li><p><strong>Utiliser une marge de s\u00e9curit\u00e9 de 2,5 \u00e0 3 fois<\/strong> au-dessus de la densit\u00e9 de puissance calcul\u00e9e.<\/p><\/li><li><p><strong>Contr\u00f4ler les d\u00e9fauts<\/strong> et maintenir les surfaces propres.<\/p><\/li><li><p><strong>Choisir une LIDT plus \u00e9lev\u00e9e<\/strong> pour des dur\u00e9es de fonctionnement plus longues ou des environnements plus difficiles.<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n<p>En suivant ces \u00e9tapes, les utilisateurs peuvent allonger le temps moyen avant d\u00e9faillance et \u00e9viter les arr\u00eats impr\u00e9vus. Des marges de s\u00e9curit\u00e9 appropri\u00e9es prot\u00e8gent \u00e0 la fois l'\u00e9quipement et l'investissement dans les disques de quartz de haute puissance \u00e0 seuil de dommage induit par le laser.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Comment la dur\u00e9e d'impulsion des disques de quartz \u00e0 diff\u00e9rents niveaux de puissance modifie-t-elle les exigences de la LIDT ?<\/h2>\n\n\n<p>La dur\u00e9e de l'impulsion joue un r\u00f4le essentiel dans la d\u00e9termination du seuil d'endommagement du laser que les disques de quartz \u00e0 haute puissance doivent respecter. La dur\u00e9e de chaque impulsion laser, combin\u00e9e au niveau de puissance, affecte directement la fa\u00e7on dont les dommages se produisent et le moment o\u00f9 ils se produisent. La compr\u00e9hension de ces relations aide les utilisateurs \u00e0 s\u00e9lectionner les disques de quartz appropri\u00e9s pour un fonctionnement s\u00fbr et fiable.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Lois d'\u00e9chelonnement de la dur\u00e9e d'impulsion : De la femtoseconde \u00e0 l'onde entretenue<\/h3>\n\n\n<p>Des impulsions laser plus courtes exigent des valeurs de seuil de dommages induits par le laser beaucoup plus \u00e9lev\u00e9es pour les disques de quartz. Lorsque la dur\u00e9e de l'impulsion passe de la microseconde \u00e0 la femtoseconde, l'\u00e9nergie d\u00e9livr\u00e9e dans chaque impulsion devient plus concentr\u00e9e. Cette concentration augmente le risque de dommages, m\u00eame si la puissance moyenne reste la m\u00eame.<\/p>\n\n\n<p>Les ing\u00e9nieurs utilisent une loi d'\u00e9chelle pour pr\u00e9dire l'\u00e9volution du seuil en fonction de la dur\u00e9e de l'impulsion. La relation suit la r\u00e8gle de la racine carr\u00e9e : LIDT(\u03c4) = LIDT(10ns) \u00d7 (\u03c4\/10ns)^0,5. Par exemple, une impulsion de 1 ns n\u00e9cessite environ trois fois le seuil d'une impulsion de 10 ns. Cette r\u00e8gle aide les utilisateurs \u00e0 adapter les exigences de la LIDT aux diff\u00e9rents syst\u00e8mes laser.<\/p>\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Points cl\u00e9s \u00e0 retenir :<\/strong><\/p><ul><li><p><strong>Des impulsions plus courtes n\u00e9cessitent une LIDT plus \u00e9lev\u00e9e.<\/strong><\/p><\/li><li><p><strong>Loi d'\u00e9chelle : La LIDT augmente lorsque la dur\u00e9e de l'impulsion diminue.<\/strong><\/p><\/li><li><p><strong>Un calcul correct permet d'\u00e9viter des dommages inattendus.<\/strong><\/p><\/li><\/ul><\/blockquote>\n\n\n<h3 class=\"wp-block-heading\">Transitions du m\u00e9canisme de dommage : Ionisation vs. thermique \u00e0 diff\u00e9rents niveaux de puissance<\/h3>\n\n\n<p>Les disques de quartz subissent diff\u00e9rents types de dommages en fonction de la dur\u00e9e et de la puissance de l'impulsion. <a target=\"_blank\" rel=\"nofollow\" href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC10753527\/\">Les impulsions plus longues, telles que les microsecondes ou les ondes continues, provoquent principalement des dommages thermiques.<\/a> Le disque s'\u00e9chauffe et la temp\u00e9rature peut d\u00e9passer les limites de s\u00e9curit\u00e9, entra\u00eenant des fissures ou une fonte.<\/p>\n\n\n<p>Lorsque le laser utilise des impulsions plus courtes, comme des femtosecondes ou des picosecondes, le m\u00e9canisme d'endommagement change. Les effets non thermiques, tels que l'ionisation, deviennent plus importants. Ces effets brisent les liaisons dans le quartz sans trop chauffer, ce qui entra\u00eene des fractures nettes et moins de d\u00e9bris.<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>R\u00e9sum\u00e9 des transitions des dommages :<\/strong><\/p><ul><li><p><strong>Impulsions longues :<\/strong> Les dommages thermiques dominent.<\/p><\/li><li><p><strong>Impulsions courtes :<\/strong> L'ionisation et les effets non thermiques dominent.<\/p><\/li><li><p><strong>Transition :<\/strong> Lorsque la dur\u00e9e de l'impulsion se raccourcit, le principal m\u00e9canisme d'endommagement change.<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n<p>Ce changement signifie que les utilisateurs doivent adapter la LIDT du disque de quartz au type de dommage attendu pour chaque application laser.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Conversion des sp\u00e9cifications LIDT : Fluence (J\/cm\u00b2) vs. densit\u00e9 de puissance (W\/cm\u00b2)<\/h3>\n\n\n<p>Les valeurs de seuil des dommages induits par le laser utilisent des unit\u00e9s diff\u00e9rentes selon le type de laser. Les lasers puls\u00e9s utilisent la fluence, mesur\u00e9e en joules par centim\u00e8tre carr\u00e9 (J\/cm\u00b2). Les lasers \u00e0 ondes continues utilisent la densit\u00e9 de puissance, mesur\u00e9e en watts par centim\u00e8tre carr\u00e9 (W\/cm\u00b2).<\/p>\n\n\n<p>La conversion entre ces unit\u00e9s d\u00e9pend de la dur\u00e9e de l'impulsion et du taux de r\u00e9p\u00e9tition. Pour les lasers puls\u00e9s, les ing\u00e9nieurs multiplient l'\u00e9nergie par impulsion par le nombre d'impulsions et divisent par la surface. Pour les lasers \u00e0 ondes entretenues, ils utilisent la puissance constante sur la surface du disque. Cette conversion garantit que le seuil correspond \u00e0 l'exposition r\u00e9elle au laser.<\/p>\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"><col style=\"min-width: 25px;\"><col style=\"min-width: 25px;\"><col style=\"min-width: 25px;\"><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Type de laser<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Unit\u00e9 LIDT<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Comment calculer<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Risque de dommage principal<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Impulsion<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>J\/cm\u00b2<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u00c9nergie par impulsion\/zone<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ionisation\/thermique<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Onde continue<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>W\/cm\u00b2<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Puissance\/surface<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Thermique<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n<p>Une sp\u00e9cification LIDT correcte prot\u00e8ge les disques de quartz des dommages soudains et \u00e0 long terme induits par le laser.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Comment la longueur d'onde des disques de quartz modifie-t-elle les exigences en mati\u00e8re de LIDT dans les diff\u00e9rentes gammes de puissance ?<\/h2>\n\n\n<p>La longueur d'onde d'un laser modifie la fa\u00e7on dont les disques de quartz r\u00e9agissent \u00e0 une exposition de forte puissance. Diff\u00e9rentes longueurs d'onde provoquent diff\u00e9rents types de dommages, de sorte que les ing\u00e9nieurs doivent ajuster le seuil de dommage laser que les disques de quartz exigent pour les \u00e9quipements de haute puissance. La compr\u00e9hension de ces effets aide les utilisateurs \u00e0 s\u00e9lectionner les disques appropri\u00e9s pour chaque application.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Effets de l'\u00e9nergie des photons : Effets multiphoton des UV et dommages thermiques des IR<\/h3>\n\n\n<p>Les lasers ultraviolets ont une \u00e9nergie photonique \u00e9lev\u00e9e. Ces photons peuvent rompre les liaisons atomiques dans le quartz par absorption multiphotonique, ce qui provoque des dommages induits par le laser, m\u00eame \u00e0 une puissance moyenne plus faible. Les lasers infrarouges ont une \u00e9nergie photonique plus faible et causent donc principalement des dommages thermiques en chauffant le quartz.<\/p>\n\n\n<p>Les ing\u00e9nieurs constatent que les lasers UV cr\u00e9ent davantage de centres de couleur et de d\u00e9fauts dans le quartz. Ce processus augmente le risque de dommages, en particulier dans les optiques laser de forte puissance. En revanche, les lasers IR entra\u00eenent g\u00e9n\u00e9ralement une fusion ou une fissuration due \u00e0 l'accumulation de chaleur, qui d\u00e9pend de l'\u00e9nergie totale d\u00e9livr\u00e9e.<\/p>\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Points cl\u00e9s \u00e0 retenir :<\/strong><\/p><ul><li><p><strong>Lasers UV :<\/strong> Provoquent des dommages multiphotoniques et la formation de centres de couleur.<\/p><\/li><li><p><strong>Lasers IR :<\/strong> Entra\u00eenent des dommages thermiques et la fonte.<\/p><\/li><li><p><strong>\u00c9nergie des photons :<\/strong> D\u00e9termine le principal m\u00e9canisme d'endommagement.<\/p><\/li><\/ul><\/blockquote>\n\n\n<p>Ces diff\u00e9rences montrent pourquoi la longueur d'onde est importante lors de l'\u00e9tablissement du seuil de dommages induits par le laser pour les disques de quartz.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Facteurs d'\u00e9chelle LIDT sp\u00e9cifiques \u00e0 la longueur d'onde pour les ajustements du niveau de puissance<\/h3>\n\n\n<p>Le seuil requis pour les dommages induits par le laser varie en fonction de la longueur d'onde. Les lasers UV n\u00e9cessitent des disques de quartz avec des valeurs LIDT plus \u00e9lev\u00e9es que les lasers IR \u00e0 la m\u00eame puissance. Par exemple, un laser UV de 3 kW \u00e0 355 nm n\u00e9cessite un seuil de 27-30 J\/cm\u00b2, alors qu'un laser IR de 3 kW \u00e0 1 064 nm ne n\u00e9cessite que 18 J\/cm\u00b2.<\/p>\n\n\n<p>Les ing\u00e9nieurs utilisent des facteurs d'\u00e9chelle pour ajuster les valeurs LIDT aux diff\u00e9rentes longueurs d'onde. Ils multiplient le seuil de r\u00e9f\u00e9rence par 1,5-2,0 pour les UV et le r\u00e9duisent de 0,8-0,9 pour l'IR lointain. Cet ajustement permet de s'assurer que le disque de quartz peut supporter l'\u00e9nergie laser sp\u00e9cifique et \u00e9viter d'\u00eatre endommag\u00e9.<\/p>\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"><col style=\"min-width: 25px;\"><col style=\"min-width: 25px;\"><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Longueur d'onde<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Facteur d'\u00e9chelle LIDT<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Type de dommage principal<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>UV (&lt;400 nm)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1.5-2.0\u00d7<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Centre multiphoton\/couleur<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Visible\/IR<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1.0\u00d7<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Mixte<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>IR lointain (&gt;5 000 nm)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>0.8-0.9\u00d7<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Thermique<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n<p>Ce tableau montre comment la longueur d'onde affecte le seuil et le type de dommage qui peut en r\u00e9sulter.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Formation de centres de couleur dans les syst\u00e8mes UV de haute puissance<\/h3>\n\n\n<p>Les lasers UV de forte puissance peuvent cr\u00e9er des centres de couleur dans les disques de quartz. Ces centres de couleur sont des d\u00e9fauts qui absorbent davantage d'\u00e9nergie laser, ce qui r\u00e9duit la r\u00e9sistance du disque \u00e0 d'autres dommages. Au fil du temps, ce processus peut entra\u00eener une d\u00e9faillance rapide des optiques des lasers \u00e0 haute puissance.<\/p>\n\n\n<p>Les ing\u00e9nieurs testent la formation des centres de couleur \u00e0 l'aide de m\u00e9thodes telles que le balayage de trame et le test S-on-1. Les <a target=\"_blank\" rel=\"nofollow\" href=\"https:\/\/lidaris.com\/tests\/raster-scan-lidt-test\/\">le balayage de la trame d\u00e9tecte les d\u00e9fauts rares<\/a> et mesure l'\u00e9volution de la densit\u00e9 des dommages en fonction de l'exposition. <a target=\"_blank\" rel=\"nofollow\" href=\"https:\/\/lidaris.com\/tests\/s-on-1-lidt-test\/\">Les tests S-on-1 r\u00e9v\u00e8lent le disque<\/a> \u00e0 des impulsions laser r\u00e9p\u00e9t\u00e9es afin de d\u00e9terminer le v\u00e9ritable seuil d'endommagement.<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>R\u00e9sum\u00e9 des meilleures pratiques :<\/strong><\/p><ul><li><p><strong>Contr\u00f4ler la croissance du centre de couleur<\/strong> dans les syst\u00e8mes UV.<\/p><\/li><li><p><strong>Utiliser le balayage de trame et les tests S-on-1<\/strong> pour une mesure pr\u00e9cise du seuil.<\/p><\/li><li><p><strong>S\u00e9lectionner les disques de quartz<\/strong> avec une r\u00e9sistance prouv\u00e9e \u00e0 la formation de centres color\u00e9s.<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n<p>Des tests appropri\u00e9s et la s\u00e9lection des mat\u00e9riaux permettent de maintenir le seuil de dommage induit par le laser et de prolonger la dur\u00e9e de vie des disques de quartz dans les \u00e9quipements de haute puissance.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Quels niveaux de puret\u00e9 des disques de quartz permettent d'obtenir des valeurs LIDT \u00e9lev\u00e9es dans diff\u00e9rentes gammes de puissance ?<\/h2>\n\n\n<p>La puret\u00e9 du mat\u00e9riau joue un r\u00f4le essentiel dans la d\u00e9termination de la r\u00e9sistance des disques de quartz \u00e0 une exposition au laser de forte puissance. La pr\u00e9sence d'impuret\u00e9s peut abaisser le seuil d'endommagement du laser et augmenter le risque de d\u00e9faillance. Le choix du bon niveau de puret\u00e9 garantit que les disques de quartz r\u00e9pondent aux exigences des \u00e9quipements de haute puissance \u00e0 seuil de dommage laser.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Absorption m\u00e9di\u00e9e par les impuret\u00e9s : Calculs de chauffage en fonction de la puissance<\/h3>\n\n\n<p>Les impuret\u00e9s du quartz absorbent l'\u00e9nergie du laser et cr\u00e9ent un \u00e9chauffement localis\u00e9. Cet \u00e9chauffement peut causer des dommages m\u00eame si la puissance globale semble s\u00fbre. Le risque augmente avec la puissance du laser.<\/p>\n\n\n<p>Le quartz fondu de haute puret\u00e9, avec au moins 99,99% SiO\u2082, r\u00e9duit l'absorption d'impuret\u00e9s et maintient la temp\u00e9rature stable. Une puret\u00e9 moindre permet aux ions m\u00e9talliques d'absorber plus d'\u00e9nergie, ce qui entra\u00eene des points chauds et des dommages pr\u00e9coces. Les ing\u00e9nieurs calculent l'effet de chauffage en multipliant la concentration d'impuret\u00e9s par l'intensit\u00e9 du laser, ce qui montre que m\u00eame de petites quantit\u00e9s de m\u00e9tal peuvent augmenter le risque.<\/p>\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Points cl\u00e9s pour les ing\u00e9nieurs :<\/strong><\/p><ul><li><p><strong>Une grande puret\u00e9 r\u00e9duit l'absorption et les dommages.<\/strong><\/p><\/li><li><p><strong>L'\u00e9chauffement par les impuret\u00e9s augmente avec la puissance.<\/strong><\/p><\/li><li><p><strong>Des calculs pr\u00e9cis permettent d'\u00e9viter les d\u00e9faillances inattendues.<\/strong><\/p><\/li><\/ul><\/blockquote>\n\n\n<h3 class=\"wp-block-heading\">Impuret\u00e9s m\u00e9talliques critiques : Fe, Ti, Al Limites de concentration par niveau de puissance<\/h3>\n\n\n<p>Le fer, le titane et l'aluminium sont les impuret\u00e9s les plus nocives pour les disques de quartz utilis\u00e9s dans les syst\u00e8mes laser. M\u00eame \u00e0 l'\u00e9tat de traces, ces m\u00e9taux peuvent abaisser le seuil d'endommagement et r\u00e9duire la dur\u00e9e de vie du disque. Les lasers \u00e0 haute puissance exigent des limites plus strictes pour ces \u00e9l\u00e9ments.<\/p>\n\n\n<p>\u00c0 faible puissance, le quartz standard contenant jusqu'\u00e0 80 ppm de m\u00e9taux totaux peut donner de bons r\u00e9sultats. \u00c0 mesure que la puissance augmente, la concentration autoris\u00e9e tombe \u00e0 moins de 10 ppm pour chaque m\u00e9tal. Cette r\u00e9duction garantit que le quartz peut r\u00e9sister aux dommages induits par le laser et maintenir ses performances dans le temps.<\/p>\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"><col style=\"min-width: 25px;\"><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Puret\u00e9 du mat\u00e9riau (SiO\u2082)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Exigence<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Quartz fondu de haute puret\u00e9<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2265 99.99%<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n<p>Ce tableau met en \u00e9vidence le lien direct entre la puret\u00e9 et la capacit\u00e9 \u00e0 r\u00e9sister \u00e0 une exposition au laser de forte puissance.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Analyse co\u00fbts-avantages : Prime de puret\u00e9 vs. capacit\u00e9 de puissance<\/h3>\n\n\n<p>Le choix d'un quartz de plus grande puret\u00e9 augmente le co\u00fbt, mais il accro\u00eet \u00e9galement la r\u00e9sistance du disque aux dommages. Les utilisateurs doivent mettre en balance le prix et le besoin de fiabilit\u00e9 dans les applications \u00e0 haute puissance. Le bon \u00e9quilibre d\u00e9pend de la puissance du laser et des heures de fonctionnement pr\u00e9vues.<\/p>\n\n\n<p>Les disques de quartz de tr\u00e8s haute puret\u00e9 co\u00fbtent plus cher mais offrent une dur\u00e9e de vie plus longue et moins de remplacements. Par exemple, une plaque de silice fondue GE214 de haute pr\u00e9cision co\u00fbte $18-$20 par pi\u00e8ce, alors qu'une plaque standard de qualit\u00e9 UV varie entre $4,50 et $10. L'investissement suppl\u00e9mentaire est rentabilis\u00e9 par la r\u00e9duction des temps d'arr\u00eat et la pr\u00e9vention des d\u00e9faillances co\u00fbteuses.<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>R\u00e9sum\u00e9 des principales consid\u00e9rations :<\/strong><\/p><ul><li><p><strong>Une plus grande puret\u00e9 signifie un co\u00fbt plus \u00e9lev\u00e9 mais une meilleure r\u00e9sistance aux dommages.<\/strong><\/p><\/li><li><p><strong>La dur\u00e9e de vie plus longue compense le prix initial.<\/strong><\/p><\/li><li><p><strong>Le choix de la puret\u00e9 appropri\u00e9e prot\u00e8ge \u00e0 la fois l'\u00e9quipement et le budget.<\/strong><\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n<h2 class=\"wp-block-heading\">Comment les essais de production doivent-ils valider la LIDT pour des applications de puissance sp\u00e9cifiques ?<\/h2>\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"800\" height=\"400\" src=\"https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/8ca17bcae96342d497501b555ac15219.jpg\" alt=\"Comment les essais de production doivent-ils valider la LIDT pour des applications de puissance sp\u00e9cifiques ?\" class=\"wp-image-11028\" srcset=\"https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/8ca17bcae96342d497501b555ac15219.jpg 800w, https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/8ca17bcae96342d497501b555ac15219-300x150.jpg 300w, https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/8ca17bcae96342d497501b555ac15219-768x384.jpg 768w, https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/8ca17bcae96342d497501b555ac15219-18x9.jpg 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\"><\/figcaption><\/figure>\n\n\n<p>Les tests de production garantissent que les disques de quartz respectent le seuil d'endommagement laser requis pour chaque application de puissance. Les ing\u00e9nieurs utilisent des protocoles sp\u00e9cifiques pour reproduire les conditions r\u00e9elles des syst\u00e8mes laser de haute puissance. Une validation minutieuse permet d'\u00e9viter les d\u00e9faillances pr\u00e9coces et d'assurer une fiabilit\u00e9 \u00e0 long terme.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Matrice de s\u00e9lection des protocoles de test par niveau de puissance<\/h3>\n\n\n<p>Les protocoles de test varient en fonction du niveau de puissance du laser et de l'application. Les syst\u00e8mes de faible puissance utilisent souvent des tests \u00e0 un seul tir, tandis que les syst\u00e8mes de forte puissance n\u00e9cessitent des protocoles plus rigoureux \u00e0 plusieurs tirs. Chaque m\u00e9thode vise \u00e0 r\u00e9v\u00e9ler la v\u00e9ritable LIDT dans des conditions r\u00e9alistes.<\/p>\n\n\n<p>Les ing\u00e9nieurs s\u00e9lectionnent les protocoles en adaptant le test \u00e0 la puissance du laser et \u00e0 l'environnement d'exploitation. Par exemple, un syst\u00e8me de 1 \u00e0 3 kW peut utiliser un test 1-on-1 \u00e0 1,25\u00d7 la fluence attendue, tandis que les syst\u00e8mes de 3 \u00e0 8 kW b\u00e9n\u00e9ficient d'un test S-on-1 avec des milliers de tirs par site. Les syst\u00e8mes \u00e0 ultra-haute puissance de plus de 8 kW n\u00e9cessitent des essais d'exposition \u00e0 rampe et de longue dur\u00e9e, souvent combin\u00e9s \u00e0 des contr\u00f4les environnementaux.<\/p>\n\n\n<p>Le tableau ci-dessous r\u00e9sume les principales m\u00e9thodes de test :<\/p>\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"><col style=\"min-width: 25px;\"><col style=\"min-width: 25px;\"><col style=\"min-width: 25px;\"><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Niveau de puissance<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Type de test<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Principaux points d'attention<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Impact sur la fiabilit\u00e9<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>1-3 kW<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1 contre 1<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>V\u00e9rification rapide d'un seul coup<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fiabilit\u00e9 de base<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>3-8 kW<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>S-on-1<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Multi-coup, probabilit\u00e9<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fiabilit\u00e9 accrue<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>&gt;8 kW<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>R-on-1, long<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Rampe, longue exposition<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fiabilit\u00e9 maximale<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n<h3 class=\"wp-block-heading\">Test d'incubation S-on-1 pour les syst\u00e8mes puls\u00e9s \u00e0 haut DRF<\/h3>\n\n\n<p>Le test d'incubation S-on-1 joue un r\u00f4le essentiel dans la validation des disques de quartz pour les lasers puls\u00e9s \u00e0 taux de r\u00e9p\u00e9tition \u00e9lev\u00e9. Cette m\u00e9thode expose chaque site d'essai \u00e0 des milliers d'impulsions laser, r\u00e9v\u00e9lant comment une exposition r\u00e9p\u00e9t\u00e9e peut r\u00e9duire la LIDT au fil du temps.<\/p>\n\n\n<p>Les ing\u00e9nieurs observent que les syst\u00e8mes \u00e0 haute FRP pr\u00e9sentent souvent une r\u00e9duction de 20 \u00e0 40% de la LIDT par rapport aux essais \u00e0 tir unique. Cette baisse r\u00e9sulte des effets d'incubation, o\u00f9 les petits d\u00e9fauts accumulent des dommages \u00e0 chaque impulsion. Les essais S-on-1 permettent d'identifier ces faiblesses avant que les disques n'entrent en service, ce qui garantit que seuls les mat\u00e9riaux robustes passent la qualification.<\/p>\n\n\n<p>Avant de passer \u00e0 l'\u00e9tape suivante, tenez compte des points suivants :<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Les tests S-on-1 permettent de d\u00e9tecter les faiblesses cach\u00e9es.<\/strong><\/p><\/li><li><p><strong>Les lasers \u00e0 haute r\u00e9solution n\u00e9cessitent une validation plus stricte.<\/strong><\/p><\/li><li><p><strong>Les effets de l'incubation peuvent r\u00e9duire la LIDT jusqu'\u00e0 40%.<\/strong><\/p><\/li><li><p><strong>Les tests de routine S-on-1 am\u00e9liorent la fiabilit\u00e9 \u00e0 long terme.<\/strong><\/p><\/li>\n<\/ul>\n\n\n<h3 class=\"wp-block-heading\">Imagerie thermique pendant les essais : D\u00e9tection des anomalies d'absorption<\/h3>\n\n\n<p>L'imagerie thermique est un outil puissant pour d\u00e9tecter les anomalies d'absorption lors des essais LIDT. Les ing\u00e9nieurs utilisent des cam\u00e9ras infrarouges pour surveiller la temp\u00e9rature des disques de quartz en temps r\u00e9el lorsqu'ils sont expos\u00e9s au laser.<\/p>\n\n\n<p>Cette approche r\u00e9v\u00e8le les points chauds caus\u00e9s par des impuret\u00e9s ou des d\u00e9fauts de surface, qui peuvent ne pas appara\u00eetre lors d'inspections visuelles standard. En identifiant ces zones \u00e0 un stade pr\u00e9coce, les ing\u00e9nieurs peuvent pr\u00e9venir les d\u00e9faillances inattendues et ne s\u00e9lectionner que les disques les plus performants pour les applications \u00e0 haute puissance.<\/p>\n\n\n<p>Voici un r\u00e9sum\u00e9 des meilleures pratiques pour les contr\u00f4les de qualit\u00e9 en cours :<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li><p>Un entretien r\u00e9gulier permet d'\u00e9viter la poussi\u00e8re et l'usure des composants optiques.<\/p><\/li><li><p>L'\u00e9talonnage de routine permet de maintenir les performances du laser dans les limites des param\u00e8tres d\u00e9finis.<\/p><\/li><li><p>Le contr\u00f4le de l'environnement permet de g\u00e9rer la temp\u00e9rature et l'humidit\u00e9, ce qui r\u00e9duit les risques.<\/p><\/li><li><p>Les tests de stabilit\u00e9 \u00e0 long terme permettent de suivre l'\u00e9volution de la fiabilit\u00e9 dans le temps.<\/p><\/li>\n<\/ul>\n\n\n<p>L'imagerie thermique, associ\u00e9e \u00e0 ces pratiques, garantit que les disques de quartz offrent des performances constantes dans les environnements laser exigeants.<\/p>\n\n\n<p>Le choix du seuil d'endommagement laser correct pour les disques de quartz garantit un fonctionnement s\u00fbr et fiable des \u00e9quipements laser de haute puissance. Les ing\u00e9nieurs doivent tenir compte de plusieurs facteurs pour faire le meilleur choix :<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Niveau de puissance :<\/strong> Faites correspondre le classement du disque \u00e0 la puissance du laser.<\/p><\/li><li><p><strong>Dur\u00e9e de l'impulsion et longueur d'onde :<\/strong> Ajuster la LIDT en fonction des diff\u00e9rents types de laser.<\/p><\/li><li><p><strong>Puret\u00e9 des mat\u00e9riaux et essais :<\/strong> Choisissez un quartz de haute puret\u00e9 et v\u00e9rifiez-le \u00e0 l'aide de tests appropri\u00e9s.<\/p><\/li><li><p><strong>Marges de s\u00e9curit\u00e9 :<\/strong> Utilisez des valeurs prudentes et v\u00e9rifiez les donn\u00e9es du fournisseur.<\/p><\/li>\n<\/ul>\n\n\n<p>Une s\u00e9lection rigoureuse permet de prot\u00e9ger les \u00e9quipements, de r\u00e9duire les co\u00fbts et d'assurer des performances \u00e0 long terme.<\/p>\n\n\n<h2 class=\"wp-block-heading\">FAQ<\/h2>\n\n\n<h3 class=\"wp-block-heading\">Quel est le principal facteur qui d\u00e9termine la LIDT d'un disque de quartz ?<\/h3>\n\n\n<p>Le principal facteur est la densit\u00e9 de puissance du laser sur le disque. Une densit\u00e9 de puissance plus \u00e9lev\u00e9e augmente le risque de dommages. La puret\u00e9 du mat\u00e9riau, la dur\u00e9e de l'impulsion et la longueur d'onde jouent \u00e9galement un r\u00f4le important.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Que se passe-t-il si la LIDT d'un disque de quartz est trop faible pour le syst\u00e8me laser ?<\/h3>\n\n\n<p>Un disque dont la LIDT est faible peut se fissurer, fondre ou tomber en panne pr\u00e9matur\u00e9ment. Cela peut entra\u00eener des temps d'arr\u00eat co\u00fbteux et endommager d'autres composants du laser. Les utilisateurs doivent toujours choisir des disques pr\u00e9sentant une marge de s\u00e9curit\u00e9 appropri\u00e9e.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Quel niveau de puret\u00e9 les disques de quartz doivent-ils avoir pour les lasers de haute puissance ?<\/h3>\n\n\n<p>Les disques de quartz destin\u00e9s aux lasers de haute puissance doivent avoir une puret\u00e9 d'au moins 99,99% SiO\u2082. Des niveaux d'impuret\u00e9 plus faibles, en particulier pour les m\u00e9taux tels que Fe, Ti et Al, permettent d'\u00e9viter les \u00e9chauffements localis\u00e9s et les d\u00e9faillances pr\u00e9coces.<\/p>\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Conseil :<\/strong> V\u00e9rifiez toujours la certification de puret\u00e9 du fournisseur avant d'acheter.<\/p><\/blockquote>\n\n\n<h3 class=\"wp-block-heading\">Quelle est la diff\u00e9rence entre la LIDT pour les lasers puls\u00e9s et les lasers \u00e0 ondes entretenues ?<\/h3>\n\n\n<p>Les lasers puls\u00e9s n\u00e9cessitent des valeurs LIDT plus \u00e9lev\u00e9es car les impulsions courtes cr\u00e9ent des pics d'intensit\u00e9 plus \u00e9lev\u00e9s. Les lasers \u00e0 ondes entretenues se concentrent sur le traitement thermique. La LIDT correcte d\u00e9pend du type de laser et de l'application.<\/p>\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"><col style=\"min-width: 25px;\"><col style=\"min-width: 25px;\"><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Type de laser<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>LIDT Focus<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Risque principal<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Impulsion<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Intensit\u00e9 maximale<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Dommages soudains<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>CW<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Gestion de la chaleur<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Chauffage progressif<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n<h3 class=\"wp-block-heading\">Quelle m\u00e9thode d'essai permet le mieux de valider la LIDT pour une utilisation industrielle ?<\/h3>\n\n\n<p>Les tests S-on-1 avec des milliers d'impulsions par site simulent au mieux les conditions industrielles r\u00e9elles. Cette m\u00e9thode permet de r\u00e9v\u00e9ler des faiblesses que les tests \u00e0 un seul coup risquent de manquer, ce qui garantit des performances fiables dans les environnements de production.<\/p>","protected":false},"excerpt":{"rendered":"<p>Calculer le seuil d'endommagement laser requis pour les lasers \u00e0 fibre, les syst\u00e8mes CO\u2082 et UV. Valeurs LIDT en fonction de la puissance, crit\u00e8res de s\u00e9lection des mat\u00e9riaux et essais de qualification de la production pour les disques optiques en quartz.<\/p>","protected":false},"author":2,"featured_media":11026,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[10],"tags":[],"class_list":["post-11029","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.4 (Yoast SEO v25.4) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Preventing Laser Window Failure: LIDT Requirements Explained\u4e28TOQUARTZ\u00ae<\/title>\n<meta name=\"description\" content=\"Calculate required laser damage threshold for fiber laser, CO\u2082, and UV systems. Power-dependent LIDT values, material selection criteria, and production qualification testing for quartz optical discs.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/toquartz.com\/fr\/laser-window-damage-threshold-specifications-guide\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What Laser Damage Threshold Do Quartz Discs Need for High-Power Laser Equipment?\" \/>\n<meta property=\"og:description\" content=\"Calculate required laser damage threshold for fiber laser, CO\u2082, and UV systems. Power-dependent LIDT values, material selection criteria, and production qualification testing for quartz optical discs.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/toquartz.com\/fr\/laser-window-damage-threshold-specifications-guide\/\" \/>\n<meta property=\"og:site_name\" content=\"TOQUARTZ: Quartz Glass Solution\" \/>\n<meta property=\"article:published_time\" content=\"2026-01-10T18:00:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/67fc7862018848b9adcd5eb0495138da.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"ECHO\u00a0YANG\u200b\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"ECHO\u00a0YANG\u200b\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"13 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/\"},\"author\":{\"name\":\"ECHO\u00a0YANG\u200b\",\"@id\":\"https:\/\/toquartz.com\/#\/schema\/person\/64de60160e69ad73646f68c4a56a90d3\"},\"headline\":\"What Laser Damage Threshold Do Quartz Discs Need for High-Power Laser Equipment?\",\"datePublished\":\"2026-01-10T18:00:43+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/\"},\"wordCount\":2886,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/toquartz.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/67fc7862018848b9adcd5eb0495138da.jpg\",\"articleSection\":[\"Blogs\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/\",\"url\":\"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/\",\"name\":\"Preventing Laser Window Failure: LIDT Requirements Explained\u4e28TOQUARTZ\u00ae\",\"isPartOf\":{\"@id\":\"https:\/\/toquartz.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/67fc7862018848b9adcd5eb0495138da.jpg\",\"datePublished\":\"2026-01-10T18:00:43+00:00\",\"description\":\"Calculate required laser damage threshold for fiber laser, CO\u2082, and UV systems. Power-dependent LIDT values, material selection criteria, and production qualification testing for quartz optical discs.\",\"breadcrumb\":{\"@id\":\"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/#primaryimage\",\"url\":\"https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/67fc7862018848b9adcd5eb0495138da.jpg\",\"contentUrl\":\"https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/67fc7862018848b9adcd5eb0495138da.jpg\",\"width\":800,\"height\":400,\"caption\":\"What Laser Damage Threshold Do Quartz Discs Need for High-Power Laser Equipment?\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/toquartz.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Blogs\",\"item\":\"https:\/\/toquartz.com\/blogs\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"What Laser Damage Threshold Do Quartz Discs Need for High-Power Laser Equipment?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/toquartz.com\/#website\",\"url\":\"https:\/\/toquartz.com\/\",\"name\":\"TOQUARTZ\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/toquartz.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/toquartz.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/toquartz.com\/#organization\",\"name\":\"TOQUARTZ\",\"url\":\"https:\/\/toquartz.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/toquartz.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/toquartz.com\/wp-content\/uploads\/2025\/02\/logo-2.png\",\"contentUrl\":\"https:\/\/toquartz.com\/wp-content\/uploads\/2025\/02\/logo-2.png\",\"width\":583,\"height\":151,\"caption\":\"TOQUARTZ\"},\"image\":{\"@id\":\"https:\/\/toquartz.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/toquartz.com\/#\/schema\/person\/64de60160e69ad73646f68c4a56a90d3\",\"name\":\"ECHO\u00a0YANG\u200b\",\"url\":\"https:\/\/toquartz.com\/fr\/author\/webadmin\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Pr\u00e9venir la d\u00e9faillance des fen\u00eatres laser : Les exigences de la LIDT expliqu\u00e9es\u4e28TOQUARTZ\u00ae.","description":"Calculer le seuil d'endommagement laser requis pour les lasers \u00e0 fibre, les syst\u00e8mes CO\u2082 et UV. Valeurs LIDT en fonction de la puissance, crit\u00e8res de s\u00e9lection des mat\u00e9riaux et essais de qualification de la production pour les disques optiques en quartz.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/toquartz.com\/fr\/laser-window-damage-threshold-specifications-guide\/","og_locale":"fr_FR","og_type":"article","og_title":"What Laser Damage Threshold Do Quartz Discs Need for High-Power Laser Equipment?","og_description":"Calculate required laser damage threshold for fiber laser, CO\u2082, and UV systems. Power-dependent LIDT values, material selection criteria, and production qualification testing for quartz optical discs.","og_url":"https:\/\/toquartz.com\/fr\/laser-window-damage-threshold-specifications-guide\/","og_site_name":"TOQUARTZ: Quartz Glass Solution","article_published_time":"2026-01-10T18:00:43+00:00","og_image":[{"width":800,"height":400,"url":"https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/67fc7862018848b9adcd5eb0495138da.jpg","type":"image\/jpeg"}],"author":"ECHO\u00a0YANG\u200b","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"ECHO\u00a0YANG\u200b","Dur\u00e9e de lecture estim\u00e9e":"13 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/#article","isPartOf":{"@id":"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/"},"author":{"name":"ECHO\u00a0YANG\u200b","@id":"https:\/\/toquartz.com\/#\/schema\/person\/64de60160e69ad73646f68c4a56a90d3"},"headline":"What Laser Damage Threshold Do Quartz Discs Need for High-Power Laser Equipment?","datePublished":"2026-01-10T18:00:43+00:00","mainEntityOfPage":{"@id":"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/"},"wordCount":2886,"commentCount":0,"publisher":{"@id":"https:\/\/toquartz.com\/#organization"},"image":{"@id":"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/67fc7862018848b9adcd5eb0495138da.jpg","articleSection":["Blogs"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/","url":"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/","name":"Pr\u00e9venir la d\u00e9faillance des fen\u00eatres laser : Les exigences de la LIDT expliqu\u00e9es\u4e28TOQUARTZ\u00ae.","isPartOf":{"@id":"https:\/\/toquartz.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/#primaryimage"},"image":{"@id":"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/67fc7862018848b9adcd5eb0495138da.jpg","datePublished":"2026-01-10T18:00:43+00:00","description":"Calculer le seuil d'endommagement laser requis pour les lasers \u00e0 fibre, les syst\u00e8mes CO\u2082 et UV. Valeurs LIDT en fonction de la puissance, crit\u00e8res de s\u00e9lection des mat\u00e9riaux et essais de qualification de la production pour les disques optiques en quartz.","breadcrumb":{"@id":"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/#primaryimage","url":"https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/67fc7862018848b9adcd5eb0495138da.jpg","contentUrl":"https:\/\/toquartz.com\/wp-content\/uploads\/2025\/10\/67fc7862018848b9adcd5eb0495138da.jpg","width":800,"height":400,"caption":"What Laser Damage Threshold Do Quartz Discs Need for High-Power Laser Equipment?"},{"@type":"BreadcrumbList","@id":"https:\/\/toquartz.com\/laser-window-damage-threshold-specifications-guide\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/toquartz.com\/"},{"@type":"ListItem","position":2,"name":"Blogs","item":"https:\/\/toquartz.com\/blogs\/"},{"@type":"ListItem","position":3,"name":"What Laser Damage Threshold Do Quartz Discs Need for High-Power Laser Equipment?"}]},{"@type":"WebSite","@id":"https:\/\/toquartz.com\/#website","url":"https:\/\/toquartz.com\/","name":"TOQUARTZ","description":"","publisher":{"@id":"https:\/\/toquartz.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/toquartz.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/toquartz.com\/#organization","name":"TOQUARTZ","url":"https:\/\/toquartz.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/toquartz.com\/#\/schema\/logo\/image\/","url":"https:\/\/toquartz.com\/wp-content\/uploads\/2025\/02\/logo-2.png","contentUrl":"https:\/\/toquartz.com\/wp-content\/uploads\/2025\/02\/logo-2.png","width":583,"height":151,"caption":"TOQUARTZ"},"image":{"@id":"https:\/\/toquartz.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/toquartz.com\/#\/schema\/person\/64de60160e69ad73646f68c4a56a90d3","name":"ECHO YANG","url":"https:\/\/toquartz.com\/fr\/author\/webadmin\/"}]}},"_links":{"self":[{"href":"https:\/\/toquartz.com\/fr\/wp-json\/wp\/v2\/posts\/11029","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/toquartz.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/toquartz.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/toquartz.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/toquartz.com\/fr\/wp-json\/wp\/v2\/comments?post=11029"}],"version-history":[{"count":1,"href":"https:\/\/toquartz.com\/fr\/wp-json\/wp\/v2\/posts\/11029\/revisions"}],"predecessor-version":[{"id":11034,"href":"https:\/\/toquartz.com\/fr\/wp-json\/wp\/v2\/posts\/11029\/revisions\/11034"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/toquartz.com\/fr\/wp-json\/wp\/v2\/media\/11026"}],"wp:attachment":[{"href":"https:\/\/toquartz.com\/fr\/wp-json\/wp\/v2\/media?parent=11029"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/toquartz.com\/fr\/wp-json\/wp\/v2\/categories?post=11029"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/toquartz.com\/fr\/wp-json\/wp\/v2\/tags?post=11029"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}